文献速递主动脉疾病

EVAR以瘤样髂总动脉为锚定区时远端密封的重要性

Importance of Distal Sealing during Endovascular Aneurysm Repair Using Aneurysmal Common Iliac Artery as Landing Zone.
PubMed 文献 · Ann Vasc Surg · 2020-01-14

该回顾性研究纳入2007至2015年EVAR以髂总动脉为锚定区且随访至少3年的病例,定义瘤样CIA为最大直径≥18mm,比较正常与瘤样CIA的中期结果。瘤样CIA组CIA相关并发症5年无事件率显著低于正常CIA组(69.4% vs 97.3%,P<0.001),未密封段长度是唯一危险因素,未密封≥10mm为不完全密封,HR 3.92(95%CI 1.62-9.46,P=0.02)。结论:瘤样CIA作锚定区增加并发症风险,但最大程度密封瘤样段可预防。

要点

  • 瘤样髂总动脉(≥18mm)作EVAR锚定区增加CIA相关并发症风险。
  • 未密封CIA段≥10mm为不完全密封,并发症风险增加约4倍。
  • 最大程度密封瘤样CIA段可降低远期并发症。

核心结论

  • 使用瘤样CIA作为锚定区增加CIA相关并发症风险。
  • 最大程度密封瘤样CIA段可预防这些并发症。

研究设计与样本

  • 回顾性研究,纳入2007至2015年EVAR以CIA为锚定区且随访至少3年的病例。
  • 定义瘤样CIA为最大直径≥18mm,比较正常CIA与瘤样CIA的中期结果。
  • 在瘤样CIA中分析CIA相关并发症的危险因素。

主要发现

  • 正常CIA组发生4例并发症(平均随访66.5±22.1个月),瘤样CIA组发生21例(平均随访62.2±20.5个月)。
  • 5年无CIA相关并发症率正常CIA为97.3%,瘤样CIA为69.4%(P<0.001)。
  • 瘤样CIA多因素分析显示未密封CIA段长度是CIA相关并发症的唯一危险因素。
  • 根据ROC曲线定义未密封CIA段≥10mm为不完全密封,其与CIA相关并发症的风险比HR 3.92(95%CI 1.62-9.46,P=0.02)。

关键数值与推荐

  • 瘤样CIA定义为最大直径≥18mm。
  • 不完全密封定义为未密封CIA段≥10mm。
  • 不完全密封与CIA相关并发症的风险比HR 3.92(95%CI 1.62-9.46,P=0.02)。

临床怎么用

  • EVAR以瘤样CIA为锚定区时应尽量最大化密封瘤样段。
  • 术中应评估未密封CIA段长度,避免≥10mm的不完全密封。
  • 对瘤样CIA患者需加强远期随访以监测CIA相关并发症。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although the use of aneurysmal common iliac artery (CIA) as the landing zone during endovascular aortic aneurysm repair EVAR remains an essential procedure, this procedure may increase the risk of late complications such as ongoing CIA dilatation and type Ib endoleak (CIA-related complications). We hypothesized that incomplete sealing of the aneurysmal CIA segment during EVAR could increase the incidence of CIA-related complications. In this study, we evaluated the midterm results of EVAR with aneurysmal CIA used as the landing zone and assessed the importance of distal sealing in this procedure. METHODS: We retrospectively reviewed all cases of endovascular aneurysm repair using CIA as landing zone between 2007 and 2015 that had at least 3 years' follow-up. We defined aneurysmal CIA as maximum diameter ≥18 mm. The main outcome was the incidence of CIA-related complications. We compared midterm results between normal CIA and aneurysmal CIA. Next, we analyzed risk factors for CIA-related complications in aneurysmal CIA. RESULTS: Four complications occurred in normal CIA (mean follow-up, 66.5 ± 22.1 months); 21 occurred in aneurysmal CIA (mean follow-up, 62.2 ± 20.5 months). The 5-year portion of freedom from CIA-related complications was 97.3% in normal CIA and 69.4% in aneurysmal CIA (P < 0.001). Multivariable analysis in aneurysmal CIA showed that unsealed CIA segment length was only risk factor for CIA-related complications. Given the receiver operating characteristic curve results, we defined the unsealed CIA segment ≥10 mm as incomplete sealing. The hazard ratio for incomplete sealing associated with CIA-related complications was 3.92 (95% confidence interval 1.62-9.46, P = 0.02). CONCLUSIONS: Use of aneurysmal CIA as landing zone increases the risk of CIA-related complications. However, maximum sealing of the aneurysmal CIA segment could prevent these complications.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Shintani T, Mitsuoka H, Hasegawa Y, et al. Importance of Distal Sealing during Endovascular Aneurysm Repair Using Aneurysmal Common Iliac Artery as Landing Zone. Ann Vasc Surg. 2020. PMID: 31953142. doi:10.1016/j.avsg.2020.01.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。