文献速递主动脉疾病

肾上型腹主动脉瘤修复模拟中冷肾脏灌注减少大鼠全身氧化应激和乙状结肠损伤

Cold Renal Perfusion During Simulation of Juxtarenal Aortic Aneurysm Repair Reduces Systemic Oxidative Stress and Sigmoid Damage in Rats.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2019-01-01

该研究在28只雄性Wistar大鼠中模拟肾上型腹主动脉瘤开放修复术,比较假手术、无肾脏灌注、温(37°C)和冷(4°C)肾脏灌注四组。结果显示冷肾脏灌注可减轻血清肌酐升高,并减少全身活性氧产生和乙状结肠损伤。

要点

  • 冷肾脏灌注可减轻肾上型钳夹后的肾脏损伤。
  • 冷肾脏灌注减少循环白细胞活性氧产生和乙状结肠损伤。
  • 温或冷肾脏灌注均改善乙状结肠微循环并减少白细胞浸润。

核心结论

  • 肾上型钳夹后肾脏缺血再灌注损伤降低乙状结肠微循环血流,增加全身活性氧产生、白细胞浸润和I-FABP漏出。
  • 冷肾脏灌注优于温灌注,可减少肾脏损伤并对乙状结肠损伤有全身性保护作用。

研究设计与样本

  • 在28只雄性Wistar大鼠中模拟肾上型腹主动脉瘤开放修复术。
  • 肾上型钳夹45分钟,随后肾下型主动脉钳夹20分钟。
  • 分为四组:假手术、无肾脏灌注、温(37°C盐水)肾脏灌注和冷(4°C盐水)肾脏灌注。

主要发现

  • 仅冷肾脏灌注可防止血清肌酐升高:无灌注0.45 mg/dL,温灌注0.33 mg/dL,冷灌注0.14 mg/dL(p = .009)。
  • 温(p = .002)和冷肾脏灌注(p = .002)均减弱乙状结肠微循环。
  • 仅冷灌注后活性氧产生增加较小(p = .034);温(p = .006)和冷灌注(p = .018)后乙状结肠白细胞浸润减少。
  • 消化酶漏出在无灌注组(1.5AU)高于温灌注组(1.3AU;p = .007)和冷灌注组(1.2AU;p = .002)。

临床怎么用

  • 在肾上型主动脉钳夹期间,冷肾脏灌注可能有助于减轻肾脏损伤和远端乙状结肠损伤。
  • 该实验性结果需进一步临床验证,目前不能直接改变临床实践。

局限性

  • 研究为大鼠实验模型,样本量28只,结果外推至人类需谨慎。
  • 原文摘要未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Juxtarenal aortic surgery induces renal ischaemia reperfusion, which contributes to systemic inflammatory tissue injury and remote organ damage. Renal cooling during suprarenal cross clamping has been shown to reduce renal damage. It is hypothesised that renal cooling during suprarenal cross clamping also has systemic effects and could decrease damage to other organs, like the sigmoid colon. METHODS: Open juxtarenal aortic aneurysm repair was simulated in 28 male Wistar rats with suprarenal cross clamping for 45 min, followed by 20 min of infrarenal aortic clamping. Four groups were created: sham, no, warm (37 °C saline), and cold (4 °C saline) renal perfusion during suprarenal cross clamping. Primary outcomes were renal damage and sigmoid damage. To assess renal damage, procedure completion serum creatinine rises were measured. Peri-operative microcirculatory flow ratios were determined in the sigmoid using laser Doppler flux. Semi-quantitative immunofluorescence microscopy was used to measure alterations in systemic inflammation parameters, including reactive oxygen species (ROS) production in circulating leukocytes and leukocyte infiltration in the sigmoid. Sigmoid damage was assessed using digestive enzyme (intestinal fatty acid binding protein - I-FABP) leakage, a marker of intestinal integrity. RESULTS: Suprarenal cross clamping caused deterioration of all systemic parameters. Only cold renal perfusion protected against serum creatinine rise: 0.45 mg/dL without renal perfusion, 0.33 mg/dL, and 0.14 mg/dL (p = .009) with warm and cold perfusion, respectively. Microcirculation in the sigmoid was attenuated with warm (p = .002) and cold renal perfusion (p = .002). A smaller increase of ROS production (p = .034) was seen only after cold perfusion, while leukocyte infiltration in the sigmoid colon decreased after warm (p = .006) and cold perfusion (p = .018). Finally, digestive enzyme leakage increased more without (1.5AU) than with warm (1.3AU; p = .007) and cold renal perfusion (1.2AU; p = .002). CONCLUSIONS: Renal ischaemia/reperfusion injury after suprarenal cross clamping decreased microcirculatory flow, increased systemic ROS production, leukocyte infiltration, and I-FABP leakage in the sigmoid colon. Cold renal perfusion was superior to warm perfusion and reduced renal damage and had beneficial systemic effects, reducing sigmoid damage in this experimental study.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. van Schaik TG, Jongkind V, Lindhout RJ, et al. Cold Renal Perfusion During Simulation of Juxtarenal Aortic Aneurysm Repair Reduces Systemic Oxidative Stress and Sigmoid Damage in Rats. Eur J Vasc Endovasc Surg. 2019. PMID: 31791617. doi:10.1016/j.ejvs.2019.05.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。