先进图像采集系统降低复杂主动脉腔内修复中的辐射暴露

Modern Image Acquisition System Reduces Radiation Exposure to Patients and Staff During Complex Endovascular Aortic Repair.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2019-12-20

该回顾性研究纳入62例复杂EVAR患者,比较Allura ClarityIQ与Allura Xper两种采集系统的辐射剂量。ClarityIQ组患者累积剂量面积乘积和空气比释动能均显著低于Xper组,表明先进剂量与实时图像降噪技术可降低患者和医护辐射暴露。

要点

  • ClarityIQ组患者累积剂量面积乘积显著低于Xper组(p<0.001)。
  • 先进剂量与实时图像降噪技术有助于降低复杂EVAR中患者和医护辐射。

核心结论

  • 先进剂量和实时图像降噪技术(如Allura ClarityIQ)可降低复杂主动脉腔内手术中患者和医护的辐射量。

研究设计与样本

  • 回顾性研究,前瞻性收集2015年6月30日至2016年5月20日连续62例复杂EVAR患者数据,平均年龄71.2±8.4岁,63%为男性。

主要发现

  • ClarityIQ组患者累积剂量面积乘积为18,948.3±14,648.5 cGy cm2,Xper组为38,512.4±24,105.4 cGy cm2,p<0.001。

临床怎么用

  • 在复杂EVAR(包括开窗或分支EVAR)中,可优先选用具备先进剂量和实时图像降噪技术的采集系统以降低辐射暴露。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Radiation damage during complex endovascular aortic repair (EVAR) is of major concern to patients and medical staff. This study investigates primarily the influence of different acquisition systems (Allura ClarityIQ vs. Allura Xper, Philips Healthcare, Best, the Netherlands) on radiation dose. Secondly, radiation exposure was analysed for operator positions as well as for procedure and patient specific parameters. METHODS: This was a retrospective study of prospectively collected data. The study prospectively included 62 consecutive patients (mean age 71.2 ± 8.4 years; 63% males) who underwent complex EVAR including fenestrated or branched EVAR of the thoraco-abdominal or the aortic arch from 30 June 2015 to 20 May 2016. In half the patients an advanced dose and real time image noise reduction technology (Allura ClarityIQ) was used, and in the other half the reference acquisition system (Allura Xper) was used. Patient demographics included age, gender, and body mass index. RESULTS: Sixty-two patients with mean age of 71.2 ± 8.4 years (63% males; 39/62) were treated using either Allura ClarityIQ or Allura Xper. Patients treated using Allura ClarityIQ had lower cumulative dose area product (18,948.3 ± 14,648.5 cGy cm2vs. 38,512.4 ± 24,105.4 cGy cm2, p < 0.001) and air kerma (2237.9 ± 1808 mGy vs. 4031 ± 3260.2 mGy, p = .010) in comparison with patients treated using Allura Xper. CONCLUSION: Advanced dose and real time image noise reduction technology, such as Allura ClarityIQ, is a useful tool to lower the amount of radiation for patient and staff during complex endovascular aortic procedures.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。