文献速递主动脉疾病内脏/肾动脉与血管畸形

七分支支架血管腔内修复变异内脏动脉解剖的胸腹主动脉瘤

Endovascular Repair Using a 7-Branch Stent-Graft for a Thoracoabdominal Aortic Aneurysm With Variant Renovisceral Artery Anatomy.
PubMed 文献 · J Endovasc Ther · 2019-12-09

一例70岁无症状男性、60mm直径IV型胸腹主动脉瘤,因严重冠心病选择血管腔内治疗。术前行CTA显示内脏动脉解剖变异,包括肝总动脉与脾动脉分别发自主动脉及双侧双肾动脉。定制七分支支架成功保留全部内脏动脉,术后6个月CTA显示瘤体隔绝且7支目标血管通畅。

要点

  • 定制七分支支架可保留变异内脏动脉解剖下的全部目标血管。
  • 术后6个月CTA显示胸腹主动脉瘤隔绝且7支目标血管通畅。
  • 严重冠心病患者可考虑血管腔内修复胸腹主动脉瘤。

核心结论

  • 对于合并多发性变异内脏动脉的胸腹主动脉瘤患者,使用定制七分支支架行血管腔内修复可行,并获得良好的早期结果。

研究设计与样本

  • 个案报告:1例70岁无症状男性,60mm直径IV型胸腹主动脉瘤,因严重冠心病选择血管腔内修复。

主要发现

  • 术前CTA显示肝总动脉与脾动脉分别发自主动脉,以及双侧双肾动脉。
  • 定制七分支支架的7个分支均经股动脉入路可调弯鞘管插管,并桥接自膨式覆膜支架,其中4支目标血管另置入球囊扩张式覆膜支架。
  • 最终造影及出院前CTA显示7支目标血管及相应内脏器官通畅,无内漏。
  • 患者术后第8天出院,无并发症;6个月随访CTA显示胸腹主动脉瘤隔绝且7支目标血管通畅。

临床怎么用

  • 对于解剖变异的胸腹主动脉瘤,可考虑定制多分支支架以保留所有内脏动脉。
  • 术前CTA详细评估内脏动脉解剖变异对制定支架分支方案至关重要。

局限性

  • 本文为单例个案报告,结论的普遍适用性有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Purpose: To present a case of endovascular repair using a custom-made 7-branch stent-graft for a thoracoabdominal aortic aneurysm (TAAA) in a patient with variations in the renovisceral artery anatomy. Case Report: A 70-year-old asymptomatic man presented with a 60-mm-diameter type IV TAAA. Due to severe coronary artery disease, an endovascular approach was elected. In the preoperative computed tomography angiography (CTA) scans, variations in the renovisceral artery anatomy included the common hepatic and splenic arteries deriving separately from the aorta and bilateral double renal arteries (RAs). A custom-made 7-branch stent-graft was manufactured to preserve all renovisceral arteries. The 7 branches were catheterized and connected with a steerable sheath from a femoral access. All branches were bridged to the target vessel (TV) with a self-expanding covered stent; 4 TVs also had balloon-expandable covered stents implanted. Final angiography and predischarge CTA showed patency of all 7 target vessels and corresponding visceral organs, with no endoleak. The patient was discharged on postoperative day 8 without complications. Six-month follow-up CTA demonstrated exclusion of the TAAA and patency of all 7 target vessels. Conclusion: Successful treatment of a TAAA in a patient with multiple variant renovisceral arteries was feasible with a custom-made 7-branch stent-graft, achieving a good early outcome.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Eleshra A, Spanos K, Panuccio G, et al. Endovascular Repair Using a 7-Branch Stent-Graft for a Thoracoabdominal Aortic Aneurysm With Variant Renovisceral Artery Anatomy. J Endovasc Ther. 2019. PMID: 31814491. doi:10.1177/1526602819892557

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。