文献速递主动脉疾病

Anaconda支架双密封环对肾周主动脉颈几何重塑的影响

Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair.
PubMed 文献 · J Endovasc Ther · 2019-01-01

本研究通过心电门控CT随访15例腹主动脉瘤患者,评估Anaconda支架双密封环径向力是否引起邻近肾周主动脉颈扩张。结果显示支架区直径和面积显著增加,支架下区多数患者直径减小,支架上区稳定。支架下区缩小可能有助于持久密封和固定。

要点

  • Anaconda支架置入后支架区主动脉颈扩张,支架下区多数患者直径减小。
  • 支架下区直径增大与主体向下移位相关。
  • 基于几何重塑的个体化随访方案可行,但需更大长期研究确认。

核心结论

  • Anaconda支架置入后肾下主动脉颈适应密封环扩张,支架区扩大,支架下区多数患者直径减小。

研究设计与样本

  • 研究评估15例择期使用Anaconda支架的腹主动脉瘤患者(平均年龄72.8±3.7岁,14例男性)的系列心电门控CT扫描,随访至术后24个月。

主要发现

  • 从出院至2年随访,支架上区直径和面积保持稳定[平均直径变化-0.1±0.4 mm(-0.4%±1.7%),p=0.893;平均面积变化-2.9±17.2 mm²(-0.7%±3.4%),p=0.946]。
  • 支架区直径和面积增加[平均直径变化+1.9±1.0 mm(+7.3%±4.0%),p<0.001;平均面积变化+84.3±48.3 mm²(+15.5%±8.7%),p<0.001]。
  • 支架下区直径和面积变化不一[平均直径变化-0.8±2.2 mm(-2.3%±7.4%),p>0.99;平均面积变化-34.6±102.3 mm²(-4.1%±14.8%),p>0.99;4例患者增加,9例患者减小]。

临床怎么用

  • 支架下区尺寸减小可能有助于持久的密封和固定。
  • 基于主动脉颈几何重塑的个体化随访方案可能可行,但需更大长期研究确认。

局限性

  • 样本量小(15例),随访2年,结论需更大长期研究证实。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Purpose: To evaluate if the radial force of the double sealing ring of the Anaconda stent-graft induces dilatation in the perirenal aortic neck adjacent to the rings. Materials and Methods: This study evaluated the serial electrocardiogram-gated computed tomography scans of 15 abdominal aortic aneurysm patients (mean age 72.8±3.7 years; 14 men) who were treated electively using an Anaconda stent-graft. Follow-up scans were conducted before discharge and at 1, 6, 12, and 24 months after endovascular repair. Diameter and area were assessed perpendicular to the aortic centerline along the perirenal aortic neck, which was subdivided into 3 zones: the suprastent, the stent, and the infrastent zones. Measurements were performed independently by 2 experienced observers using dedicated 3-dimensional image processing software. Results: Between discharge and the 2-year follow-up the diameter and area remained stable in the suprastent zone [average diameter change: -0.1±0.4 mm (-0.4%±1.7%), p=0.893; average area change: -2.9±17.2 mm2 (-0.7%±3.4%), p=0.946], increased in the stent zone [average diameter change: +1.9±1.0 mm (+7.3%±4.0%), p<0.001; average area change: +84.3±48.3 mm2 (+15.5%±8.7%), p<0.001], and diverged in the infrastent zone [average diameter change: -0.8±2.2 mm (-2.3%±7.4%), p>0.99; average area change: -34.6±102.3 mm2 (-4.1%±14.8%), p>0.99; increased in 4 patients, decreased in 9 patients]. Conclusion: After Anaconda implantation the infrarenal aortic neck accommodated to the expansion of the sealing rings at the stent zone. Below the stent zone the neck diameter decreased in the majority of patients, while an increase was related to downstream displacement of the main body. A decrease in size in the infrastent zone may contribute to durable sealing and fixation. A personalized follow-up scheme based on geometric neck remodeling should be feasible if our observations are confirmed in larger, long-term studies.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Koenrades MA, Bosscher MRF, Ubbink JT, et al. Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair. J Endovasc Ther. 2019. PMID: 31736427. doi:10.1177/1526602819882379

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。