Treovance支架治疗腹主动脉瘤:良好与不良瘤颈角度的临床结果比较
该研究基于RATIONALE上市后监测登记,比较腹主动脉瘤肾下瘤颈角<60度(FNA)与≥60度(HNA)患者使用Treovance支架行腔内修复的结局。
要点
- 两组1年临床成功率无显著差异(96.1% vs 95.2%)。
核心结论
- 高瘤颈角度患者使用Treovance行EVAR手术更复杂,但技术成功率和1年临床成功参数与良好角度患者同样良好。
研究设计与样本
- RATIONALE上市后监测登记的事后亚组分析,纳入适合Treovance腔内修复的腹主动脉瘤患者。
- 比较肾下瘤颈角<60度(FNA)与≥60度(HNA)患者,1年时分析179例FNA(89.5%)和21例HNA(10.5%)。
主要发现
- 两组临床成功率无显著差异(96.1% vs 95.2%)。
- HNA组再干预率为0%,总体再干预率低。
- 1年瘤囊大小变化两组均显著,但HNA组相对变化较小(-6.6%±11.4 vs -11.8%±13.3)。
临床怎么用
- 对于肾下瘤颈角度≥60度的腹主动脉瘤患者,使用Treovance支架需预期更复杂的手术和更长的手术时间。
- 尽管手术更复杂,高角度患者的1年临床成功率与良好角度患者相当,再干预率低。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The objective of this study was to compare outcomes of patients with favorable neck angulation (FNA) and hostile neck angulation (HNA) treated with the Treovance stent graft (Terumo Aortic [formerly Bolton Medical], Sunrise, Fla). METHODS: Patients with abdominal aortic aneurysms suitable for endovascular repair with Treovance were included in the RATIONALE postmarket surveillance registry. A post hoc subgroup analysis compared patients with infrarenal neck angles <60 degrees (FNA) and ≥60 degrees (HNA). RESULTS: After 1 year, 179 FNA (89.5%) and 21 HNA (10.5%) patients were analyzed. Both groups were similar in terms of sex (male, 92.7% FNA and 95.2% HNA) and age (73.0 years vs 72.6 years), but the HNA group had more Asian or other race representation (7.3% vs 19.0%) and more patients assigned to American Society of Anesthesiologists class 3 and class 4 (57.6% vs 66.7%). Mean suprarenal angles (standard deviation) were 13.1 (±13.5) degrees vs 29.0 (±16.4) degrees; mean infrarenal angles were 23.2 (±16.4) degrees vs 65.4 (±4.6) degrees, respectively. Aneurysm sac size maximum diameter was 58.1 (±9.8) mm vs 62.0 (±14.1) mm. There was a significant difference in unplanned adjunctive procedures (2.2% vs 19.0%; P = .01). Mean procedural duration was also significantly different for HNA patients, who underwent protracted operations (111.3 [±47.3] minutes vs 153.5 [±44.5] minutes; P < .0001). However, there were no significant differences in rates of clinical success (96.1% vs 95.2%). The rate of reintervention was low overall but 0% in the HNA group. Changes in sac size at 1 year were significant in both groups but not as pronounced in HNA patients (relative change of -11.8% [±13.3] vs -6.6% [±11.4]). CONCLUSIONS: Patients with high neck angulation treated with Treovance underwent more complex procedures but showed equally good technical success and 1-year clinical success parameters.
引用
- Murray D, Szeberin Z, Benevento D, et al. A comparison of clinical outcomes of abdominal aortic aneurysm patients with favorable and hostile neck angulation treated by endovascular repair with the Treovance stent graft. J Vasc Surg. 2019. PMID: 31690524. doi:10.1016/j.jvs.2019.07.096
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。