文献速递主动脉疾病

低剖面聚合物环密封支架联合裸肾动脉支架(vent技术)治疗不适合开放手术和开窗支架的近肾腹主动脉瘤

The use of a low-profile stent graft with a polymer ring sealing technology combined with bare renal stent (vent technique) in patients with juxtarenal aneurysm not eligible for open surgery and fenestrated endograft.
PubMed 文献 · J Vasc Surg · 2019-10-31

单中心回顾性研究纳入38例不适合开放手术和开窗EVAR的近肾腹主动脉瘤患者,采用Ovation支架的聚合物环密封技术联合裸肾动脉支架(vent技术)治疗。主要技术成功率94.7%,1个月主要临床成功率100%,中位随访22.4个月无动脉瘤相关死亡,2年肾动脉通畅率和免于IA型内漏均为100%。

要点

  • vent技术联合Ovation支架可用于不适合开放手术和开窗EVAR的近肾腹主动脉瘤患者。
  • 近端瘤颈<5 mm(平均3.3±1.2 mm)患者中主要技术成功率为94.7%。
  • 中位随访22.4个月无动脉瘤相关死亡,无瘤颈扩张或支架移位。

核心结论

  • vent技术安全可行,扩大了因解剖限制不适合开放手术和开窗EVAR的近肾腹主动脉瘤患者的治疗范围。

研究设计与样本

  • 单中心回顾性综述,纳入2015年1月至2018年12月采用Ovation vent技术治疗的38例近肾腹主动脉瘤患者,均评估为不适合开放手术且不适合开窗支架。
  • vent技术为超低剖面Ovation支架密封环靠近肾动脉开口的改良超说明书释放联合短裸金属支架。
  • 排除标准为最低肾动脉水平直径>31 mm。

主要发现

  • 所有病例近端瘤颈<5 mm(平均3.3±1.2 mm),16例患者双侧植入vent肾支架。
  • 主要技术成功率为94.7%(36/38),2例因IA型内漏立即处理成功。
  • 1个月主要临床成功率为100%。
  • 中位随访22.4±3.6个月(范围1-46个月),无动脉瘤相关死亡,无失访。
  • 1年和2年生存率分别为96.4%和91.6%(标准误0.57%)。

临床怎么用

  • 对于不适合开放手术和开窗EVAR的近肾腹主动脉瘤患者,可考虑采用Ovation vent技术作为治疗选择。
  • 该技术需注意排除最低肾动脉水平直径>31 mm的病例。

局限性

  • 单中心回顾性研究,样本量38例,随访时间有限(中位22.4个月)。
  • vent技术为超说明书使用,需进一步研究验证长期效果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: In cases of juxtarenal abdominal aortic aneurysm (jAAA), endovascular aneurysm repair (EVAR) involves the use of custom-made fenestrated stent grafts, which usually need large-diameter access vessels, superior costs, and a certain time between graft planning and delivery. We report our preliminary experience using the bare renal stent technique (called vent) in combination with the ultralow-profile stent graft Ovation (Endologix, Irvine, Calif) to seal jAAAs in patients evaluated to be unfit for open surgery and not suitable for fenestrated endograft. METHODS: A single-center retrospective review of jAAAs treated by Ovation vent technique from January 2015 to December 2018 was conduced. The vent procedure consisted of a modified, off-label deployment of the sealing ring of the ultralow-profile Ovation stent graft close to renal orifices in combination with short bare-metal stents. The exclusion criterion was a diameter >31 mm at the level of the lowest renal artery. Early technical and clinical results, estimated midterm survival, renal artery patency, freedom from type IA endoleak, freedom from reintervention, and freedom from neck enlargement (>2 mm) were reported. RESULTS: Overall, 38 patients had jAAA and were considered unfit for open repair and not eligible for fenestrated EVAR. The proximal neck was <5 mm in all cases (mean, 3.3 ± 1.2 mm). Vent renal stents were implanted bilaterally in 16 patients. Primary technical success was 94.7% (36/38), with satisfactory cannulation of all renal arteries and sealing of the aneurysm in all but two cases because of type IA endoleaks that were treated immediately with success. Primary clinical success at 1 month was 100%. During a median follow-up period of 22.4 ± 3.6 months (range, 1-46 months), no abdominal aortic aneurysm-related deaths occurred, and no patient was lost to follow-up. The survival curve at 1 year and 2 years was, respectively, 96.4% and 91.6% (standard error, 0.57%). There were no cases of neck dilation or endograft migration. Freedom from reintervention at 12 months and 24 months was 100% and 89.5%, respectively (standard error, 0.7%); freedom from type IA endoleak was 100% and patency of the renal artery was 100% at 2 years. CONCLUSIONS: The described technique includes the use of a low-profile stent graft with a polymer ring sealing technology combined with bare renal stents that are not competing for the same room. This early experience shows that the vent technique is safe and feasible and increases the range of treatment of those patients with jAAA who are unfit for open repair and for fenestrated EVAR because of several anatomic constraints.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. de Donato G, Pasqui E, Mele M, et al. The use of a low-profile stent graft with a polymer ring sealing technology combined with bare renal stent (vent technique) in patients with juxtarenal aneurysm not eligible for open surgery and fenestrated endograft. J Vasc Surg. 2019. PMID: 31676183. doi:10.1016/j.jvs.2019.06.220

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。