文献速递主动脉疾病内脏/肾动脉与血管畸形

TX2远端组件支架行TEVAR并有意覆盖腹腔干治疗Crawford I型胸腹主动脉瘤的中期结果

Mid-Term Results of Thoracic Endovascular Aneurysm Repair with Intentional Celiac Artery Coverage for Crawford Type I Thoracoabdominal Aortic Aneurysms with the TX2 Distal Component Endograft.
PubMed 文献 · Ann Vasc Surg · 2019-11-25

本研究回顾性分析16例Crawford I型胸腹主动脉瘤患者,采用Zenith TX2胸主动脉远端组件支架行TEVAR并有意覆盖腹腔干以确保远端锚定区。技术成功率100%,无动脉瘤相关死亡,平均随访40.5个月,10例(62.5%)动脉瘤缩小>5 mm,中期结果可接受。

要点

  • TEVAR联合有意覆盖腹腔干可用于解剖合适的Crawford I型胸腹主动脉瘤,技术成功率高。
  • 中期随访无动脉瘤相关死亡,但需警惕内脏缺血等主要不良事件。
  • 动脉瘤缩小>5 mm见于62.5%病例,中期结果可接受。

核心结论

  • 对解剖合适的Crawford I型胸腹主动脉瘤,使用TX2远端组件支架行TEVAR并有意覆盖腹腔干的中期结果可接受。

研究设计与样本

  • 回顾性病例系列,2010年8月至2017年7月共治疗16例Crawford I型胸腹主动脉瘤患者。
  • 采用Zenith TX2胸主动脉远端组件支架行TEVAR并有意覆盖腹腔干。

主要发现

  • 术前平均动脉瘤直径57.7 ± 8.0 mm。
  • 技术成功率100%,无动脉瘤相关死亡;1例发生肠系膜上动脉栓塞需开腹手术。
  • 平均观察期40.5个月,10例(62.5%)动脉瘤缩小>5 mm。
  • 术后12、36、60个月免于动脉瘤相关死亡率均为100%;免于主要不良事件(含二次干预)分别为86.7%、86.7%、77.0%。

临床怎么用

  • 对于解剖合适的Crawford I型胸腹主动脉瘤,可考虑TEVAR联合有意覆盖腹腔干以确保远端锚定区。
  • 术后需监测内脏缺血等主要不良事件,尤其是肠系膜上动脉栓塞风险。

局限性

  • 样本量小(16例),为单中心回顾性研究,结果需更大规模研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Anatomically suitable Crawford type I (C-I) thoracoabdominal aortic aneurysm (TAAA) can be treated by thoracic endovascular aneurysm repair (TEVAR) with intentional celiac artery (CA) coverage to ensure distal seal. We report on mid-term results of TEVAR with intentional CA coverage for C-I TAAA. METHODS: Between August 2010 and July 2017, we treated 16 cases of C-I TAAA by TEVAR with intentional CA coverage using the Zenith TX2 Thoracic Distal Component Endograft. The primary end point was aneurysm shrinkage. Secondary end points were technical success, aneurysm-related death (ARD), and major adverse events (MAEs) including stroke, paraplegia, visceral ischemia, endoleak, and secondary intervention. RESULTS: The preoperative mean aneurysm size was 57.7 ± 8.0 mm. The technical success rate was 100%. There was no aneurysm-related mortality; however, one patient suffered from superior mesenteric artery embolization, which required an open laparotomy. The mean observational period was 40.5 months, and aneurysm shrinkage of >5 mm was observed in 10 cases (62.5%). At 12, 36, and 60 months after the procedure, freedom from ARD was 100%, 100%, and 100%, respectively, whereas freedom from MAE including secondary intervention was 86.7%, 86.7%, and 77.0%, respectively. CONCLUSIONS: Mid-term results of TEVAR with intentional CA coverage for C-I TAAA were acceptable.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Fukushima S, Ohki T, Kanaoka Y, et al. Mid-Term Results of Thoracic Endovascular Aneurysm Repair with Intentional Celiac Artery Coverage for Crawford Type I Thoracoabdominal Aortic Aneurysms with the TX2 Distal Component Endograft. Ann Vasc Surg. 2019. PMID: 31778761. doi:10.1016/j.avsg.2019.11.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。