文献速递主动脉疾病

主动脉瘤颈-内移植物界面动态密封的 cohesive zone 建模新方法

Dynamic seal at the aortic neck-endograft interface studied using a novel method of cohesive zone modeling.
PubMed 文献 · J Vasc Surg · 2019-11-11

该研究开发了一种全整合的计算方法,用 cohesive zone 模型模拟主动脉-内移植物密封区的动态密封,可模拟密封失效与内漏。利用患者特异性几何,预测了1例近肾动脉瘤破裂患者的破裂位置,并提出弹性-粘附密封模型解释瘤颈扩张驱动密封失效。

要点

  • cohesive zone 模型可全动态模拟主动脉与内移植物的分离,预测密封失效位置。
  • 密封失效与主动脉瘤颈中弹性前沿的传播相关。
  • 提出弹性-粘附密封模型:瘤颈扩张提供能量释放机制驱动密封失效。

核心结论

  • 开发了首个全整合的主动脉-内移植物密封计算模型,提出弹性-粘附密封模型作为评估密封失效的首个生物力学模型。

研究设计与样本

  • 计算建模研究:采用标准有限元分析模拟主动脉、内移植物和腔内血栓在压力载荷下的弹性响应,密封区用 cohesive zone 方法建模。

主要发现

  • 利用患者特异性几何,预测了1例近肾动脉瘤破裂患者的破裂位置。
  • 在不同密封强度(非常弱、标准、非常强)下研究内移植物稳定性,显示密封失效与主动脉瘤颈中弹性前沿的传播相关。
  • 提出主动脉瘤颈扩张(由移植物释放和加压引起)提供能量释放机制驱动密封区失效。

临床怎么用

  • 该方法有望用于研究I型内漏的棘手问题,并指导优化密封的技术开发。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Endovascular aortic stent graft technology radically altered aortic aneurysm repair from a maximally invasive procedure to a minimally invasive approach. Whereas the overall principle of the repair remained the same, the surgeon ceded control of the proximal seal when suturing was eliminated. In endovascular aneurysm repair (EVAR), no longer does the surgeon control the precise placement of mechanical fasteners (sutures) between graft and tissue; rather, the graft is kept in place by creation of a seal zone that often lacks any mechanical fastening. The kinematic coupling condition is replaced by contact mechanics between the outer graft surface and the aorta. METHODS: We develop a novel computational methodology to fully model and characterize the aorta-endograft seal zone within a fully integrated aorta-EVAR model. The aorta, endograft, and intraluminal thrombus are modeled by standard finite element analysis in the limit of elastic response under pressure loading conditions. The seal zone in our simulations is fully dynamic and modeled using the cohesive zone method. Our methodology allows full separation of the aorta and endograft, simulating loss of seal and endoleak. RESULTS: Using patient-specific geometry, we show that our approach is capable of predicting the location of rupture in an index patient who presented with a ruptured juxtarenal aneurysm. Applying our novel cohesive zone method analysis to the post-EVAR geometry, we studied the stability of the endograft under several seal zone strengths correlating to very weak, standard, and very strong seal. Loss of seal is shown to correlate to the propagation of an elastic front in the aortic neck. We propose that aortic neck dilation, which develops from graft deployment and pressurization, provides an energy release mechanism that drives seal zone failure: the elasto-adhesive seal model. CONCLUSIONS: We develop the first ever fully integrated computational model of aorta-endograft seal. Our elasto-adhesive seal model provides the first biomechanical model to evaluate seal loss. We hope that our method will provide a rich tool set with which to study the vexing problems of type I endoleak and help guide the development of technologies to optimize seal.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Pocivavsek L, Milner R. Dynamic seal at the aortic neck-endograft interface studied using a novel method of cohesive zone modeling. J Vasc Surg. 2019. PMID: 31727454. doi:10.1016/j.jvs.2019.07.101

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。