急诊原位激光开窗辅助TEVAR治疗不适合开放手术的急性Stanford A型主动脉夹层
本研究回顾性分析20例不适合开放手术的急性Stanford A型主动脉夹层患者,接受急诊原位激光开窗辅助胸主动脉腔内修复(TEVAR)。手术成功率100%,30天死亡率10%,30天卒中率5%,平均随访16个月,24个月生存率77.1%。结论认为该方法是安全有效的替代方案。
要点
- 急诊ISLF辅助TEVAR治疗不适合开放手术的急性Stanford A型夹层手术成功率100%。
- 30天死亡率10%,30天卒中率5%,24个月生存率77.1%。
- 随访期间无支架移位、开窗相关内漏,覆盖段假腔均血栓化。
核心结论
- 急诊原位激光开窗辅助TEVAR是不适合开放手术的急性Stanford A型主动脉夹层安全有效的替代方法。
研究设计与样本
- 腔内修复解剖标准:冠状动脉和主动脉瓣未受累,近端锚定区直径≤45 mm,近端锚定区长度≥20 mm。
主要发现
- 20例患者手术成功率100%。
- 30天死亡率10%(2例死亡:1例重症肺炎,1例术后脑出血)。
- 30天卒中率5%。
- 平均随访16个月(范围3-26个月),术后23个月1例死于心力衰竭。
- Kaplan-Meier曲线分析显示24个月生存率77.1%。
关键数值与推荐
- 腔内修复解剖标准:冠状动脉和主动脉瓣未受累,近端锚定区直径≤45 mm,近端锚定区长度≥20 mm。
临床怎么用
- 对于不适合开放手术的急性Stanford A型主动脉夹层,可考虑急诊ISLF辅助TEVAR作为替代治疗。
- 需严格筛选解剖条件符合的患者:冠状动脉和主动脉瓣未受累,近端锚定区直径≤45 mm且长度≥20 mm。
局限性
- 回顾性研究,样本量较小(20例),随访时间有限(平均16个月)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study investigated the outcomes of emergency in situ laser fenestration (ISLF)-assisted thoracic endovascular aortic repair (TEVAR) for patients with acute Stanford type A aortic dissection unfit for open surgery. METHODS: Twenty patients with acute Stanford type A aortic dissection who were found to be unfit for open surgery, underwent emergency ISLF-assisted TEVAR in our center between March 2016 and December 2018. Anatomic criteria for endovascular repair: coronary artery and aortic valve was not involved, proximal landing zone diameter of 45 mm or less, and proximal landing zone length of 20 mm or greater. Their clinical outcomes were reviewed retrospectively. RESULTS: Twenty patients achieved a procedural success of 100.0%. The 30-day mortality was 10%; two patients died, one of severe pneumonia and the other from cerebral hemorrhage after the operation. Rate of stroke at 30 days was 5%. The average follow-up time was 16 months (range, 3-26 months). One death owing to heart failure occurred at 23 months postoperatively. Kaplan-Meier curve analysis revealed that the 24-month survival rate was 77.1%. Two patients had type Ia endoleaks and one had a type II endoleak. There was no stent graft migration or fenestration-related endoleak and all patients had a thrombosed false lumen in the covered section of the stent grafts. No reintervention, myocardial infarction, transient ischemic attacks, cerebral infarction, or other complications occurred during the follow-up period. CONCLUSIONS: Emergency ISLF-assisted TEVAR is a safe and effective alternative method for treating acute Stanford type A aortic dissection unfit for open surgery.
引用
- Yan D, Shi H, Qin J, et al. Outcomes of emergency in situ laser fenestration-assisted thoracic endovascular aortic repair in patients with acute Stanford type A aortic dissection unfit for open surgery. J Vasc Surg. 2019. PMID: 31676177. doi:10.1016/j.jvs.2019.08.233
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。