股浅动脉入路用于血管腔内主动脉修复术
单中心回顾性研究纳入2014至2016年195例患者共215次血管腔内主动脉修复术,比较股浅动脉(SFA)与股总动脉(CFA)切开入路。SFA组穿刺点出血、缺血和伤口并发症更少,住院时间缩短14.3%,但神经病变(多为感觉性)更多。SFA入路可作为CFA切开或经皮入路的替代选择。
要点
- SFA入路穿刺点出血(0.7% vs 7%,P=.004)和缺血(0.7% vs 7.6%,P=.002)显著低于CFA。
- SFA组伤口并发症(感染、血清肿、血肿)为13.2%,显著低于CFA组的34.9%(P=.000)。
- SFA组神经病变(多为感觉性)为13.8%,高于CFA组的5.2%(P=.008)。
核心结论
- SFA入路操作更简单,并发症率低于CFA入路,可作为经皮入路不适用时的替代选择。
- 术中无需分离或损伤动脉分支,尤其不损伤股深动脉。
研究设计与样本
- 单中心回顾性研究,纳入2014至2016年195例患者共215次血管腔内主动脉修复术。
- 其中114次为CFA切开,87次为SFA切开,14次为SFA联合CFA手术。
- 采用独立样本双侧t检验和χ2检验比较SFA与CFA组,P<.05为差异有统计学意义,并用多因素校正模型确认结果。
主要发现
- 两组年龄、性别、危险因素分布、动脉瘤大小和设备直径相似。
- 12.1%的病例不适合SFA入路。
- SFA组穿刺点出血0.7% vs CFA组7%(P=.004),缺血0.7% vs 7.6%(P=.002),静脉损伤0% vs 1.3%(P=.102)。
- SFA组术中需额外动脉重建者6.5% vs CFA组12.8%(P=.059),伤口并发症13.2% vs 34.9%(P=.000),神经病变13.8% vs 5.2%(P=.008)。
- SFA组住院时间缩短14.3%(P=.005),二次入路相关手术2.2% vs 8.7%(P=.045)。
关键数值与推荐
- 术前通过CT血管造影评估近端SFA的通畅性和适用性,考虑SFA入路的最小SFA直径为6 mm。
- 通过大腿上部纵向切口暴露并置管SFA,无鞘插入器械后更换为小直径鞘(14F-16F)。
- 术前和术后进行外周血管检查。
临床怎么用
- 对于经皮入路不适用且需避免CFA切开并发症的患者,可考虑SFA切开入路。
- 术前应通过CT血管造影评估SFA直径和通畅性,最小直径6 mm为考虑标准。
- 术后需注意监测神经病变(多为感觉性),并告知患者该风险高于CFA入路。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The majority of endovascular aneurysm repair procedures are performed through the common femoral artery (CFA). Arterial access is gained by surgical cutdown or percutaneous approach. The surgical approach has a relatively high local complication rate. We describe superficial femoral artery (SFA) access as an alternative to CFA exposure to minimize wound complications and to facilitate swift recovery. METHODS: A single-center, retrospective study of patients undergoing endovascular aneurysm repair between 2014 and 2016 was performed; 195 patients undergoing 215 procedures were included, 114 with CFA cutdown, 87 with SFA cutdown, and 14 with combined SFA and CFA procedures. Epidemiologic parameters, risk factors, procedural details, operative and postoperative complications, and time to discharge were assessed. Independent samples two-sided t-test and χ2 test were used to compare the SFA and CFA. A P value < .05 was considered statistically significant. A multivariate adjusted model confirmed the results. The proximal SFA is assessed by computed tomography angiography for patency and suitability. The minimal SFA diameter of 6 mm was determined for considering SFA access. Through a longitudinal incision at the upper thigh, the SFA is exposed and catheterized. Devices are inserted sheathless and replaced by small-diameter sheaths (14F-16F). Patients undergo peripheral vascular examination before and after the procedure. RESULTS: Age, sex, and risk factor distribution were similar in both groups. Aneurysm size and device diameters were also similar. There were 12.1% of cases that were not suitable for the SFA approach. Access-related bleeding (0.7% SFA, 7% CFA; P = .004), ischemia (0.7% SFA, 7.6% CFA; P = .002), and venous injury (0% SFA, 1.3% CFA; P = .102) were minimized with SFA exposure. This led to almost 50% decrease in patients requiring additional arterial reconstruction during the procedure (6.5% SFA, 12.8% CFA; P = .059). SFA cutdown was also associated with lower wound complication rate (infection, seroma, and hematoma; 13.2% SFA, 34.9% CFA; P = .000). Neuropathy (mostly sensory) was higher with SFA exposure (13.8% SFA, 5.2% CFA; P = .008). The patients' recovery was faster in the SFA group, resulting in 14.3% reduction of hospital stay after the procedure (P = .005). Secondary access-related procedures were also lower in the SFA group (2.2% SFA, 8.7% CFA; P = .045). CONCLUSIONS: The SFA approach is easier to perform and has a lower complication rate compared with the CFA approach. During the procedure, there is no dissection or damage to arterial branches, especially to the deep femoral artery. The SFA approach has a low complication rate and can be an alternative to percutaneous access when it is unsuitable.
引用
- Avraham E, Natour M, Obaid W, et al. Superficial femoral artery access for endovascular aortic repair. J Vasc Surg. 2019. PMID: 31699510. doi:10.1016/j.jvs.2019.07.081
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。