直径≥17mm髂总动脉腔内治疗后的体积变化:1b型内漏风险因素评估
本研究评估了直径≥17mm的髂总动脉(CIA)在腔内治疗后的体积演变及1b型内漏危险因素。
核心结论
- BBT与CIA术后体积增加相关,可视为1b型内漏的危险因素;如有可能使用髂动脉分支支架,应避免BBT。
研究设计与样本
- 回顾性队列研究,纳入2008至2016年连续74例患者共110条直径≥17mm的CIA,分为BBT组(n=58)和非BBT组(n=52)。
主要发现
- BBT组和非BBT组1b型内漏平均发生时间分别为24.8个月和54.3个月。
临床怎么用
- 对于CIA直径≥17mm的腔内治疗,应优先考虑髂动脉分支支架以规避BBT相关的1b型内漏风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The aim of this study was to assess the post-operative volumetric evolution of common iliac arteries (CIA) ≥ 17 mm diameter with respect to the type of endovascular technique performed and to assess type 1b endoleak risk factors. METHODS: All consecutive patients presenting with aneurysmal disease with CIA ≥17 mm treated endovascularly from 2008 to 2016 were included. Patients were divided into two groups dependent upon the type of endovascular technique performed: bell bottom technique (BBT group), vs. other techniques (non-BBT group). Volumetric evolution of the CIA was assessed for each patient by computed tomography angiographic reconstructions performed pre-operatively, at six months, one year, and two years. Multivariable analysis was performed to identify risk factors for type 1b endoleak. RESULTS: From 2008 to 2016, 74 patients with 110 CIA ≥17 mm were treated (BBT group: n = 58; non-BBT group: n = 52). Mean follow up was 48.1 months (median 39.0, IQR 38.1). Mean volumetric evolution significantly differed in the BBT group +14.2% (median 19.9%, IQR 24.6) compared with the non-BBT group: -20.9% (median -20.1%, IQR -26.0), p < .001. The five year type 1b endoleak related re-intervention rate was 16.1% and 7.7% in the BBT and non-BBT groups, respectively (p = .04), mean time to type 1b endoleak was 24.8 months and 54.3 months, respectively. The BBT appeared as a risk factor for type 1b endoleak (OR: 7.13; 95% CI: 1.58-3.04; p < .001). CONCLUSION: The BBT is associated with an increase in CIA volume post-operatively and consequently can be considered a risk factor for type 1b endoleak. It might be avoided if an iliac branched endograft is possible.
引用
- Rouby AF, Kuntz S, Delay C, et al. Volume Change after Endovascular Treatment of Common Iliac Arteries ≥ 17 mm Diameter: Assessment of Type 1b Endoleak Risk Factors. Eur J Vasc Endovasc Surg. 2019. PMID: 31732469. doi:10.1016/j.ejvs.2019.06.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。