远端流入道重建术对高流量透析通路动脉血流特征的影响
本研究纳入15例高流量透析通路患者,采用多普勒超声评估RUDI术后2个月和12个月的血流特征与动脉直径。术后2个月流量下降,但12个月时再次升高;肱动脉直径未变,近端桡动脉直径翻倍。结论提示RUDI不能逆转肱动脉扩张,可能因不可逆结构损伤导致高流量复发。
要点
- RUDI术后12个月透析通路流量再次升高,可能复发高流量。
- RUDI不能逆转肱动脉扩张,提示动脉壁结构损伤不可逆。
- 既往合并手缺血者桡动脉重塑减弱,高流量复发可能性较低。
核心结论
- RUDI降低高流量后不能逆转肱动脉扩张,提示可能存在不可逆的动脉壁结构损伤并导致高流量复发。
研究设计与样本
- 前瞻性观察研究,纳入15例(54±16岁,10例男性)高流量透析通路患者,于2011年3月至2016年在两家荷兰医院接受RUDI。
主要发现
- RUDI术后2个月肱动脉流量从2740±322 mL/min降至1180±189 mL/min,12个月时回升至1520±217 mL/min(P < .001)。
- 肱动脉直径术后无变化(7.4±0.5 mm),但近端前臂桡动脉直径从2.6±0.2 mm增至5.4±1.0 mm(P < .001)。
- 近端前臂桡动脉扩张在HFA-HAIDI组为+80%,低于HFA组的+130%(P = .019)。
- 随访期间HFA-HAIDI组远端尺动脉收缩期峰值流速(83±10 cm/s)高于HFA组(54±5 cm/s;P < .01)。
- 大隐静脉间置段未出现扩张。
临床怎么用
- RUDI可用于降低高流量透析通路流量,但术后需监测流量回升及高流量复发。
- 合并手缺血的高流量患者RUDI后桡动脉重塑减弱,高流量复发风险可能较低。
局限性
- 样本量小(15例),部分患者仅评估部分动脉节段。
- 随访时间限于术后2个月和12个月,缺乏更长期数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Revision using distal inflow (RUDI) is currently proposed in patients on hemodialysis having a high flow access (HFA; >2 L/min) or hemodialysis access-induced distal ischemia (HAIDI). However, a recurrence of high flow or hand ischemia is not unusual in the years after RUDI. The aim of the present study was to describe changes in flow characteristics and arterial diameters in the dialysis arm after RUDI for HFA. METHODS: Volume flow, diameter, peak systolic velocity and end diastolic velocity of the brachial artery (BA) were studied 2 and 12 months after RUDI using duplex imaging. In a portion of patients, these characteristics were also assessed at proximal and distal portions of radial and ulnar arteries (proximal forearm radial artery, distal radial artery, ulnar artery, and distal ulnar artery), and in the greater saphenous venous interponate. HFA patients were grouped according to presence of concomitant hand ischemia (HFA-HAIDI) or absence (HFA). RESULTS: Fifteen patients (54 ± 16 year old; 10 males; HFA-HAIDI, n = 6; HFA, n = 9) with a BA HFA (flow volume, 2740 ± 322 mL/min) undergoing RUDI were studied between March 2011 and October 2016 in two Dutch hospitals. After 2 months, flow volume had decreased (1180 ± 189 mL/min), but again increased at 12 months (1520 ± 217 mL/min; P < .001). BA diameters did not change (7.4 ± 0.5 mm), but proximal forearm radial diameters doubled (overall 2.6 ± 0.2 mm to 5.4 ±1.0 mm; P < .001), albeit less prominent in HFA-HAIDI (+80%) than in HFA (+130%; P = .019). During follow-up, the distal ulnar artery peak systolic velocity in HFA-HAIDI (83 ± 10 cm/s) was higher compared with the HFA group (54 ± 5 cm/s; P < .01). Dilatation was not present in the greater saphenous venous interponate. CONCLUSIONS: RUDI for HFA reduction does not reverse BA dilatation, suggesting irreversible structural arterial wall damage possibly contributing to recurrent high flow. Radial artery remodeling is attenuated in HFA patients previously reporting concurrent hand ischemia diminishing the likelihood of high flow recurrence in this subgroup.
引用
- Gerrickens MWM, Vaes RHD, Wiersma V, et al. Revision using distal inflow for high flow hemodialysis access alters arterial flow characteristics in the dialysis arm. J Vasc Surg. 2019. PMID: 31619349. doi:10.1016/j.jvs.2019.06.197
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。