外翻式与传统颈动脉内膜剥脱术在血管质量倡议数据库中的结局比较
基于Vascular Quality Initiative数据库2003至2018年的95,726例颈动脉内膜剥脱术回顾性分析,外翻式CEA占12.6%。在均使用补片时两种术式围术期及1年卒中/死亡和再狭窄率相似;但传统CEA未用补片时,外翻式CEA的30天和1年卒中/死亡风险更低。
要点
- 传统CEA补片使用率94.9%,外翻式CEA为49.7%。
- 均用补片时两种术式1年内卒中/死亡和再狭窄率无显著差异。
- 未用补片时外翻式CEA的30天卒中/死亡OR 0.72,1年HR 0.75。
核心结论
- 传统CEA使用补片时与外翻式CEA安全性和耐久性相似。
- 未用补片时外翻式CEA优于传统CEA,30天和1年卒中/死亡分别降低28%和25%。
研究设计与样本
- 回顾性队列研究,分析Vascular Quality Initiative数据库2003至2018年数据。
- 共纳入95,726例CEA,其中外翻式12,050例(12.6%),传统CEA 87.4%。
- 排除同侧颈动脉既往干预及同期其他手术患者,采用多因素logistic和Cox回归分析。
主要发现
- 传统CEA补片使用率94.9%,外翻式CEA为49.7%(P < 0.001)。
- 单因素分析示传统CEA院内心律失常(1.5% vs. 1.3%)和术后血流动力学不稳定(27.3% vs. 24.3%)更高(P < 0.05)。
- 外翻式CEA因出血返回手术室率更高(1.3% vs. 0.9%,P < 0.001)。
- 均用补片时两种术式结局无显著差异;未用补片时外翻式CEA的30天卒中/死亡OR 0.72(95%CI 0.54-0.95,P = 0.02),1年HR 0.75(95%CI 0.58-0.97,P = 0.03)。
临床怎么用
- 传统CEA应常规使用补片以获与外翻式CEA相当的结局。
- 若计划不补片,外翻式CEA在降低30天和1年卒中/死亡方面更优。
局限性
- 回顾性数据库研究,存在选择偏倚和混杂可能。
- 随访仅至1年,缺乏长期耐久性数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although the majority of vascular surgeons perform conventional carotid endarterectomy (c-CEA), others prefer eversion CEA (e-CEA). Despite several randomized controlled trials and single center studies, the advantage of one technique over the other is still not clearly defined. The purpose of this study is to compare the postoperative outcomes and durability of c-CEA versus e-CEA in a nationally representative cohort. METHODS: We performed a retrospective review of the Vascular Quality Initiative database between 2003 and 2018. Patients with prior ipsilateral carotid intervention (CEA and carotid artery stenting) and those undergoing concomitant procedures were excluded. Multivariable logistic and Cox-regression analyses were used to compare risk-adjusted perioperative and 1-year outcomes (stroke, death, and high-grade restenosis [>70%]) between c-CEA (using direct closure or patch angioplasty) and e-CEA. RESULTS: A total of 95,726 CEA cases were included, of which 12,050 (12.6%) were e-CEA and the remaining (87.4%) were c-CEA. Patch angioplasty was used in 94.9% of c-CEA compared with 49.7% of e-CEA (P < 0.001). On univariable analysis, no difference in perioperative outcomes was noted between the 2 approaches except for higher rates of in-hospital dysrhythmia (1.5% vs. 1.3%) and postprocedural hemodynamic instability (27.3% vs. 24.3%) after c-CEA compared with e-CEA (all P < 0.05). On the other hand, e-CEA patients were more likely to return to the operating room for bleeding (1.3% vs. c-CEA: 0.9%, P < 0.001). The outcomes of e-CEA did not differ if the common carotid artery was closed primarily or with a patch. After adjusting for potential confounders and stratifying with respect to patch use, there was no significant difference in outcomes between e-CEA and c-CEA when a patch is used in both procedures. However, when no patching was performed, e-CEA was associated with lower stroke/death at 30 days (odds ratio 0.72, 95% confidence interval [CI] 0.54-0.95, P = 0.02) and at 1 year (hazard ratio 0.75, 95% CI 0.58-0.97, P = 0.03). CONCLUSIONS: Both e-CEA and c-CEA are safe and durable techniques with similar stroke/death and restenosis rates up to 1-year of follow up, as long as c-CEA is performed with patch angioplasty. However, e-CEA is superior to c-CEA without patch angioplasty and is associated with 28% and 25% reduction in 30-day and 1-year stroke/death, respectively.
引用
- Dakour-Aridi H, Ou M, Locham S, et al. Outcomes following Eversion versus Conventional Endarterectomy in the Vascular Quality Initiative Database. Ann Vasc Surg. 2019. PMID: 31626932. doi:10.1016/j.avsg.2019.07.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。