Tack植入物在膝下动脉夹层修复中的实际应用:单中心经验
结果显示该系统应用于60处(95.2%)夹层,技术成功率达98.3%,术中无主要不良事件或器械相关并发症,急性有效性与安全性结果良好。
要点
- Tack系统在真实世界膝下动脉夹层修复中技术成功率高,急性安全性良好。
- 股动脉夹层均使用膝上(ATK)系统,膝下动脉夹层均使用膝下(BTK)系统。
- 夹层长度可预测Tack植入物部署数量。
核心结论
- Tack血管内系统用于膝下动脉夹层修复在真实世界中显示出良好的急性有效性与安全性。
主要发现
- 病变以标准球囊血管成形术、药物涂层球囊血管成形术、斑块旋切术和/或碎石术等2.3±0.8次尝试完成血运重建。
- Tack血管内系统应用于63处夹层中的60处(95.2%)。
- 股动脉夹层均使用膝上(ATK)系统治疗,膝下动脉夹层均使用膝下(BTK)系统治疗,腘动脉夹层两种系统均成功应用。
- 夹层长度可预测Tack植入物部署数量。
- 技术成功率达98.3%(60处夹层中59处),术中无主要不良事件或器械相关并发症。
关键数值与推荐
- 技术成功定义为98.3%(59/60处夹层)。
- Tack系统应用比例为95.2%(60/63处夹层)。
- 股动脉夹层使用6-F膝上(ATK)Tack系统,膝下动脉夹层使用4-F膝下(BTK)Tack系统。
临床怎么用
- 对于膝下动脉腔内血运重建中出现的夹层,可根据夹层位置选择ATK或BTK Tack系统进行修复。
- 股动脉夹层选用ATK系统,膝下动脉夹层选用BTK系统,腘动脉夹层两种系统均可应用。
- 夹层长度可帮助预估所需Tack植入物数量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Purpose: To assess the practical application and acute outcomes of the Tack Endovascular System for infrainguinal dissection repair in a real-world setting. Materials and Methods: Fifty-one consecutive patients who underwent endovascular revascularization for symptomatic peripheral artery disease and experienced 63 dissections requiring treatment were included in the prospective, single-center, single-arm study between January and June 2019. Thirty-nine (76.5%) lesions were ≥10 cm in length, 33 (64.7%) were totally occluded, and 13 (25.5%) were severely calcified. Fifty-six (88.9%) dissections were classified as severe. Dissections were treated either by means of the 6-F above-the-knee (ATK) or the 4-F below-the-knee (BTK) Tack Endovascular System. Observational outcomes were conditions and scopes of application. Clinical outcomes were acute technical and procedural success as well as safety. Results: Lesions were revascularized with 2.3±0.8 attempts such as standard balloon angioplasty, drug-coated balloon angioplasty, atherectomy, and/or lithotripsy. The Endovascular System was applied in 60 (95.2%) of 63 dissections. All dissections of the femoral artery were treated with the ATK system, and all infrapopliteal dissections with the BTK system. Both systems were successfully applied in popliteal artery dissections. Dissection length predicted the number of Tack implants deployed. Technical success was achieved in 98.3% (59 of 60 dissections). No major adverse event or device-related complication occurred during the procedure. Conclusion: Acute results in effectiveness and safety of the Tack Endovascular System for infrainguinal dissection repair in a real-world setting are promising.
引用
- Lichtenberg M, Wojczik H, Stahlhoff S, et al. Practical Applications of Tack Implants for Infrainguinal Dissection Repair: A Single-Center Experience. J Endovasc Ther. 2019. PMID: 31637955. doi:10.1177/1526602819882418
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。