A型主动脉夹层冷冻象鼻术后左锁骨下动脉血栓形成的原位开窗血运重建:一例报告
本文报告一例75岁男性A型主动脉夹层患者,行冷冻象鼻全弓置换及左锁骨下动脉覆盖后,因左锁骨下动脉起始部血栓形成导致锁骨下动脉窃血综合征。通过原位激光开窗联合导管导向血栓清除术,成功血运重建左锁骨下动脉,术后支架通畅无内漏。
要点
- 原位激光开窗可为冷冻象鼻术后左锁骨下动脉延迟血运重建提供替代方案。
- 椎动脉保护与导管导向血栓清除是降低后循环卒中风险的重要辅助措施。
- 术后CT显示左锁骨下动脉分支支架通畅,开窗处无内漏。
核心结论
- 对PTFE胸主动脉支架行延迟原位激光开窗是安全可行的。
研究设计与样本
- 个案报告:一名75岁男性A型主动脉夹层患者,行冷冻象鼻修复术后出现左锁骨下动脉血栓形成,接受原位激光开窗联合导管导向血栓清除术。
主要发现
- 患者术后恢复良好,症状缓解并出院。
- 术后CT扫描显示左锁骨下动脉分支支架通畅,主动脉支架开窗处无内漏。
关键数值与推荐
- 采用9Fr Flex鞘经肱动脉切开置于锁骨下动脉起始部。
- 使用0.035英寸3.2mm over-the-wire激光斑块旋切导管穿过cTAG支架创建开窗。
- 左锁骨下动脉分支置入iCast球囊扩张覆膜支架,排除附壁血栓。
- 通过锁骨上切口以神经夹保护椎动脉起始部。
临床怎么用
- 对于冷冻象鼻术后左锁骨下动脉血栓形成且不宜以左颈动脉为流入道的患者,可考虑原位激光开窗血运重建。
- 操作中应注重椎动脉保护及导管导向血栓清除,以降低后循环卒中风险。
局限性
- 本文为单一病例报告,结论的外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Left subclavian artery revascularization during endovascular repair of aortic dissection is often accomplished by left carotid-subclavian artery bypass or transposition. In situ fenestration of thoracic stent grafts provides an alternative method of revascularization without manipulation of the left carotid artery. We describe a case whereby in situ laser fenestration, combined with catheter-directed thrombectomy, was utilized to revascularize a thrombosed left subclavian artery following a frozen elephant trunk repair of type A aortic dissection. A 75-year-old male presented with pericardial tamponade and aortic insufficiency, secondary to type A aortic dissection. Patient underwent an emergent replacement of the aortic root, valve, arch, and ascending aorta in the frozen elephant trunk configuration. The innominate and left carotid arteries were revascularized with a bifurcated bypass graft from the ascending aortic graft. The left subclavian artery (LSCA) was covered with an antegrade deployment of a cTAG stent graft. During the immediate postoperative period, the patient was found to have a dissection of the left common carotid artery (LCCA) and pseudoaneurysm of the bypass graft anastomosis. The left carotid artery was replaced up to the proximal internal carotid. During rehabilitation, the patient developed left subclavian steal syndrome, with a CT angiography demonstrating thrombosis of the subclavian origin, and duplex ultrasound showing a reversal of the left vertebral flow. In order to revascularize the left subclavian artery without using the left carotid as the inflow, the in situ laser fenestration technique was planned. The vertebral artery origin was protected with a neuroclip through a supraclavicular incision. Through a brachial artery cutdown, a 9Fr flex sheath was positioned at the origin of the subclavian artery. A suction thrombectomy catheter was used to create a central channel in the thrombus. A 0.035″ 3.2 mm over-the-wire laser atherectomy catheter was used to create a fenestration through the cTAG stent graft. The subclavian branch stent was stented with an iCast balloon-expandable covered stent, excluding the mural thrombus. The patient recovered well with resolution of symptoms and was discharged home. Postoperative CT scan showed patent left subclavian branch stent and no endoleak across the fenestration of the aortic stent graft. Delayed laser in situ fenestration of a PTFE stent graft can be performed safely. The vertebral artery protection and catheter-directed thrombectomy are important adjuncts to reduce the risk of posterior stroke.
引用
- Veranyan N, Dunn J, Bowdish M, et al. In-Situ Fenestration of a PTFE Thoracic Aortic Stent Graft for Delayed Left Subclavian Artery Revascularization Following Frozen Elephant Trunk Repair of Type A Aortic Dissection. Ann Vasc Surg. 2019. PMID: 31622763. doi:10.1016/j.avsg.2019.08.101
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。