开窗或扇形医师改良腔内移植物用于2区TEVAR的中期随访
本研究回顾54例接受扇形或开窗医师改良腔内移植物(PMEG)行2区胸主动脉腔内修复(TEVAR)的患者,技术成功率94%,围术期死亡7%,随访26±16个月,左锁骨下动脉均保持通畅,无移植物相关主动脉并发症。作者认为该技术可作为超适应证延长近端锚定区至2区的选择。
要点
- 扇形或单开窗PMEG用于2区TEVAR中期安全持久,左锁骨下动脉均保持通畅。
- 技术成功率94%,围术期死亡7%,无中转开放、破裂或逆行夹层。
- 再干预率4%,均为II型内漏,无其他内漏发生。
核心结论
- 扇形或单开窗PMEG用于左锁骨下动脉区2 TEVAR在中期的表现是持久且安全的。
主要发现
- 技术成功率为94%,3例(6%)左锁骨下动脉被意外覆盖。
- 围术期死亡4例(7%),其中2例(2%)死于动脉瘤破裂。
- 1例(2%)发生脊髓缺血导致不可逆双侧截瘫,3例(6%)术后发生轻微卒中但神经功能完全恢复。
- 平均随访26±16个月,15例(28%)随访至少3年,发现2例(4%)II型内漏并成功治疗,再干预率4%。
- 所有左锁骨下动脉在临床和影像学上均保持通畅,无中转开放、破裂、逆行夹层、支架断裂、移位或其他主动脉并发症。
临床怎么用
- 对于需要将近端锚定区延伸至2区的TEVAR,扇形或单开窗PMEG可作为超适应证替代方案。
局限性
- 需要更大样本量和长期随访研究来充分验证该方法。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Purpose: To investigate the midterm outcomes of scalloped or fenestrated physician-modified endovascular grafts (PMEGs) for zone 2 thoracic endovascular aortic repairs (TEVAR). Materials and Methods: Between November 2013 and May 2019, 54 consecutive patients (mean age 63 years; 41 men) were treated with thoracic PMEGs modified with 7 scallops or 47 fenestrations for the left subclavian artery (LSA). Indications for aortic repair were acute complicated type B aortic dissection (17, 31%), degenerative aneurysm (13, 24%), acute traumatic rupture of the aortic isthmus (9, 16%), post chronic dissection aneurysmal evolution (8, 15%), penetrating aortic ulcer (3, 6%), intramural hematoma (2, 4%), and floating thrombus (2, 4%). Results: Technical success was 94%; 3 (6%) LSAs were unintentionally covered. An intraoperative type Ia endoleak was treated during the index procedure. One (2%) patient suffered spinal cord ischemia, with irreversible bilateral paraplegia. Three (6%) patients experience postoperative minor strokes with full neurological recovery. Four (7%) patients died in the perioperative period; 2 (2%) were due to aneurysm rupture. Mean follow-up was 26±16 months; 15 (28%) patients had at least 3 years of follow-up. Two (4%) type II endoleaks were identified and successfully treated (4% reintervention rate); no other endoleaks were identified. All the LSAs remained clinically and radiologically patent. There were no conversions to open repair, ruptures, retrograde dissection, stent fracture, migrations, or other aortic complications. Conclusion: Scalloped or single-fenestrated PMEGs for the LSA appear to be durable and safe in the midterm. Combined with low periprocedural morbidity and mortality, these results suggest that this approach can be considered as an off-label alternative to extend proximal seal to zone 2 for TEVAR. Further studies with a larger number of patients and long-term outcomes are needed to fully validate this approach.
引用
- Chassin-Trubert L, Mandelli M, Ozdemir BA, et al. Midterm Follow-up of Fenestrated and Scalloped Physician-Modified Endovascular Grafts for Zone 2 TEVAR. J Endovasc Ther. 2019. PMID: 31645219. doi:10.1177/1526602819881128
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。