文献速递主动脉疾病

烟囱/三明治技术全腔内主动脉弓置换术

Total Endovascular Aortic arch Replacement with Chimney/Sandwich Techniques.
PubMed 文献 · Ann Vasc Surg · 2019-10-14

本文报告一例49岁慢性B型主动脉夹层合并降主动脉瘤及既往TEVAR后Ia型内漏患者,采用烟囱/三明治技术行全腔内zone 0主动脉弓置换。手术顺利,术后1个月及1年随访CTA显示无内漏、所有分支通畅、动脉瘤被隔绝。

要点

  • 烟囱/三明治技术为全腔内zone 0主动脉弓置换提供可行微创选择。
  • 适用于慢性B型夹层合并降主动脉瘤及既往TEVAR失败病例。
  • 术后1个月及1年随访CTA显示无内漏、分支通畅、瘤体隔绝。

核心结论

  • 烟囱/三明治技术行全腔内zone 0主动脉弓置换可行,较传统开放手术创伤小、难度低。

研究设计与样本

  • 个案报道:49岁男性慢性B型主动脉夹层合并降主动脉瘤,既往zone 3 TEVAR后Ia型内漏。

主要发现

  • 手术顺利,术后1个月及1年CTA示无内漏、所有分支通畅、动脉瘤隔绝。

关键数值与推荐

  • 近端延伸至zone 0、远端延伸的TEVAR(C-TAG)确保锚定区。
  • 左锁骨下动脉采用periscope sandwich技术(Viabahn)重建。
  • 头臂干和左颈总动脉采用烟囱技术(Viabahn)重建。

临床怎么用

  • 对于不适合开放手术的主动脉弓病变,可考虑烟囱/三明治技术全腔内修复。

局限性

  • 个案报道,证据级别低,需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Traditional open total zone 0 replacement of the aortic arch is one of the most complex, challenging, and demanding operative procedures in cardiovascular surgery, associated with significant morbidity (30-40%) and mortality (8-20%). Total endovascular zone 0 replacement of the aortic arch with chimney/sandwich techniques as described by Lobato and Camacho-Lobato is a feasible, less invasive, less demanding, and time-consuming option to hybrid and/or traditional open replacement of the aortic arch, particularly in the urgent/emergent settings. We are reporting a case of a 49-year-old patient with chronic type B aortic dissection complicated with descending thoracic aortic aneurysm and an unsuccessful zone 3 thoracic endovascular aortic repair, complicated with type Ia endoleak. He presented with an enlarging and symptomatic descending thoracic aortic aneurysm. An extended proximal (to the zone 0) and distal thoracic endovascular aortic repair was performed to ensure appropriate proximal and distal landing zones (C-TAG). Left subclavian artery endorevascularization was undertaken with periscope sandwich technique (Viabahn), while brachiocephalic trunk and left carotid artery endorevascularizations were carried on with the chimney graft technique (Viabahn). The procedure was uneventful and the one-month and one-year follow-up angio-computed tomography revealed no endoleaks, patency of all branches, and exclusion of the aneurysm.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Teixeira G, Matos A, de Almeida R, et al. Total Endovascular Aortic arch Replacement with Chimney/Sandwich Techniques. Ann Vasc Surg. 2019. PMID: 31622748. doi:10.1016/j.avsg.2019.07.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。