正常志愿者动态静脉压与柱中断时间的测量研究
研究在38名正常志愿者的76条肢体中同步测量足背静脉与大隐静脉的动态静脉压,并用双功能超声测量小腿泵射血后胫静脉和大隐静脉的柱中断时间。结果显示足背静脉与大隐静脉的关键动态静脉压参数存在显著差异,提示压力未平衡;双功能超声测得的大隐静脉柱中断时间与压力法测得的柱中断时间无显著差异。
要点
- 足背静脉测得的动态静脉压不能反映大隐静脉的小腿泵压力事件。
- 双功能超声可测量大隐静脉和胫后静脉的柱中断时间。
- 大隐静脉双功能超声柱中断时间与压力法柱中断时间无显著差异。
核心结论
- 足背静脉测量的动态静脉压不反映大隐静脉的小腿泵压力事件,因压力未平衡。
- 双功能超声测量大隐静脉柱中断时间与压力法无显著差异,可作为非侵入替代。
研究设计与样本
- 研究纳入38名正常志愿者的76条肢体。
- 在28条正常肢体中同步测量足背静脉和大隐静脉的动态静脉压。
- 通过双功能超声监测小腿射血后胫静脉和大隐静脉的血流恢复来测量柱中断时间。
主要发现
- 足背静脉和大隐静脉的关键动态静脉压参数(下降百分比和静脉再充盈时间)显著不同,显示压力未平衡。
- 双功能超声测量的大隐静脉柱中断时间与同一静脉压力法测得的柱中断时间无显著差异。
临床怎么用
- 临床评估小腿泵功能时,足背静脉动态静脉压可能不反映大隐静脉压力动态。
- 可考虑用双功能超声测量大隐静脉或胫后静脉柱中断时间作为非侵入性替代。
局限性
- 研究仅纳入正常志愿者,未在慢性静脉疾病患者中验证。
- 同步动态静脉压测量仅在28条肢体中进行。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Ambulatory venous pressure (AMVP) measurement is considered the gold standard in evaluating calf pump function in chronic venous disease. The AMVP protocol was standardized in the 1970s with pressure monitoring through the dorsal foot vein. This technique was based on the belief that it represents calf venous pressure dynamics owing to rapid equilibration in the superficial and deep systems. This notion is subject to some doubt not only on theoretical grounds, but also owing to a lack of clinical correlation in a segment of the population with chronic venous disease. Our aims were to (1) examine if AMVP measured simultaneously through the dorsal foot vein (DFV) and the great saphenous vein (GSV) would be similar and (2) attempt to devise a noninvasive substitute via duplex measurement for the AMVP test. METHODS: The study was conducted in 76 limbs in 38 normal volunteers. Simultaneous AMVP measurements in DFV and GSV were made in 28 of these normal limbs. Column interruption duration (CID) after calf pump ejection was measured by monitoring duplex resumption of flow in the tibial veins and GSV after calf ejection. The return of AMVP back to baseline implies column restoration. The venous refill time therefore represents the CID via the pressure method. The pressure and duplex methods of CID were compared in the GSV. RESULTS: Key AMVP parameters (percent drop and venous refill time) significantly differed in DFV and GSV, showing a lack of pressure equilibration. CID measured by duplex in GSV was not significantly different from pressure-derived CID in the same vein. CONCLUSIONS: AMVP measured through the DFV does not reflect calf pump generated pressure events in GSV. A duplex method of measuring CID in GSV and posterior tibial vein is described. Duplex-derived CID is not significantly different from pressure-derived CID in the GSV.
引用
- Raju S, Walker W, May C, et al. Measurement of ambulatory venous pressure and column interruption duration in normal volunteers. J Vasc Surg Venous Lymphat Disord. 2019. PMID: 31495767. doi:10.1016/j.jvsv.2019.06.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。