文献速递颈动脉与弓上血管

颈外动脉狭窄分级的双功超声标准

Duplex Criteria for Grading of External Carotid Stenosis.
PubMed 文献 · Ann Vasc Surg · 2019-09-26

研究纳入140例同期接受血管造影与颈动脉双功超声评估的患者,记录颈内动脉、颈总动脉及颈外动脉峰值流速并计算ECA/CCA PSV比值,与造影测值比较,用ROC分析确定识别ECA狭窄>50%的最佳标准。结果显示ECA PSV及ECA/CCA PSV比值有助于预测单侧重度ECA狭窄。

要点

  • 同侧ICA病变轻者,ECA PSV>148 cm/sec识别ECA狭窄≥50%的敏感度80%、特异度76.2%、准确率77.1%。
  • 同侧ICA狭窄≥50%者,ECA/CCA PSV比值≥1.89识别ECA狭窄≥50%的准确率为72.5%。
  • ECA PSV与ECA/CCA PSV比值可作为预测单侧重度ECA狭窄的有用指标。

核心结论

  • ECA PSV和ECA/CCA PSV比值似乎是预测单侧重度颈外动脉狭窄的有用指标。

研究设计与样本

  • 连续接受血管造影与颈动脉双功超声评估的患者被比较,n=140。
  • 记录ICA、CCA和ECA的峰值收缩流速(PSV),并计算ECA/CCA PSV比值。
  • 采用受试者工作特征曲线分析确定识别ECA狭窄>50%的最佳标准。

主要发现

  • 同侧ICA病变轻微者中,ECA PSV>148 cm/sec识别ECA狭窄≥50%的敏感度80%、特异度76.2%、总准确率77.1%。
  • 同侧ICA病变轻微者中,ECA/CCA PSV比值1.45的敏感度73.7%、特异度66.7%、准确率68.2%。
  • ICA狭窄≥50%者中,ECA PSV>179 cm/sec识别ECA狭窄≥50%的敏感度50%、特异度79.6%、总准确率71.3%。
  • ICA狭窄≥50%者中,ECA/CCA PSV比值≥1.89的敏感度71.9%、特异度72.7%、总准确率72.5%。

关键数值与推荐

  • ECA狭窄≥50%:ICA病变轻微者用ECA PSV>148 cm/sec或ECA/CCA PSV比值1.45。
  • ECA狭窄≥50%:ICA狭窄≥50%者用ECA PSV>179 cm/sec或ECA/CCA PSV比值≥1.89。

临床怎么用

  • 对颈外动脉狭窄评估可结合ECA PSV与ECA/CCA PSV比值,并按同侧ICA狭窄程度选用不同阈值。

局限性

  • 原文摘要未报告局限性相关内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: External carotid artery (ECA) stenosis is an independent mortality predictor. Additionally, concomitant ECA and internal carotid artery (ICA) stenosis progression has been associated with an increased risk of ipsilateral ischemic events in asymptomatic patients. Universally accepted ECA duplex velocity criteria, for the prediction of stenosis, do not exist. METHODS: Consecutive patients undergoing angiography and carotid duplex assessments were compared (n = 140). ICA, common carotid artery (CCA), and ECA peak systolic velocities (PSVs) were recorded. ECA/CCA PSV ratio was calculated. These parameters were compared with angiographic ECA measurements. Receiver-operator curve analysis was used to determine optimal criteria in identifying ECA stenosis of >50%. RESULTS: In patients with little ipsilateral ICA disease, for the detection of ECA stenosis of ≥50%, an ECA PSV >148 cm/sec provided a sensitivity of 80%, specificity of 76.2%, and an overall accuracy of 77.1%. An ECA/CCA PSV ratio of 1.45 demonstrated a sensitivity of 73.7%, specificity of 66.7%, and an accuracy of 68.2%.In patients with ICA stenosis ≥50%, for the detection of ECA stenosis of ≥50%, an ECA PSV >179 cm/sec provided a sensitivity of 50%, specificity of 79.6%, and overall accuracy of 71.3%. An ECA/CCA PSV ratio of ≥1.89 provided a sensitivity of 71.9%, specificity of 72.7%, and overall accuracy of 72.5%. CONCLUSIONS: ECA PSV and ECA/CCA PSV ratios appear as useful metrics for the prediction of unilateral high-grade ECA stenosis.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Shmelev A, Ganti A, Hosseini M, et al. Duplex Criteria for Grading of External Carotid Stenosis. Ann Vasc Surg. 2019. PMID: 31563656. doi:10.1016/j.avsg.2019.07.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。