支架移植物与多层裸支架联合技术治疗高外科风险胸腹主动脉瘤的中长期临床结果
本研究评估支架移植物与多层裸支架(MBS)联合技术治疗高外科风险胸腹主动脉瘤(TAAA)的中长期疗效。8例不适合手术的TAAA患者接受该联合手术,中位随访32个月。技术成功率达100%,无死亡或并发症,7例动脉瘤缩小,23/24覆盖分支保留。该技术可能为高手术风险患者的安全有效替代方案。
要点
- 支架移植物与MBS联合技术治疗高外科风险TAAA技术成功率100%。
- 中位随访32个月无死亡或并发症,7例动脉瘤缩小≥5mm。
- 23/24覆盖内脏分支成功保留,无内脏缺血或出血并发症。
核心结论
- 支架移植物与MBS联合技术治疗高手术风险TAAA可能安全有效。
研究设计与样本
- 回顾性分析2012年5月至2015年12月8例选择性TAAA患者(年龄46-75岁),均不适合手术修复,接受支架移植物与MBS联合手术,中位随访32个月(范围14-58个月)。
主要发现
- 技术成功8/8(100%),住院期间无并发症或死亡。
- 随访期间无死亡或并发症,7例动脉瘤最大直径缩小≥5mm,无动脉瘤扩张。
- 所有患者动脉瘤囊完全血栓形成,23/24覆盖分支成功保留,无内脏缺血或出血并发症。
关键数值与推荐
- 技术成功定义为100%(8/8)。
- 动脉瘤缩小定义为最大直径减少≥5mm,7例达到。
- 覆盖内脏分支共24条,23条成功保留。
临床怎么用
- 对于高手术风险的TAAA患者,可考虑支架移植物与MBS联合全腔内修复作为替代方案。
局限性
- 样本量小(8例),选择性病例,需更多临床证据验证安全性和有效性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This study aims to present the performance data on stent-graft and multilayer bare stents (MBS) joint technique in the treatment of high-risk thoracoabdominal aortic aneurysm (TAAA). METHODS: From May 2012 to December 2015, 8 selective TAAA cases (ages 46-75 years) ineligible for surgical repair underwent the stent-graft and MBS joint procedure, and were closely followed up for a median of 32 months (range 14-58). Using computed tomography images, the aneurysm size, luminal blood flow diameter, and the covered visceral branches were analyzed. RESULTS: Technical success was achieved in all patients (100%, 8/8). Twenty-four visceral branches were covered by MBS in total. There was no complication or death during hospital stay. During follow-up period, no death or complication occurred. Aneurysm shrinkage (maximum diameter decrease ≥5 mm) was observed in 7 patients. No aneurysm expansion was observed. Total aneurysm sac thrombosis was observed in all patients. The majority of covered side branches (23/24) were successfully preserved. No visceral ischemia or bleeding complications was observed during follow-up. CONCLUSIONS: Total endovascular repair of TAAA using stent-graft and MBS joint technique may be a safe and effective alternative in high surgical risk patients. More approving clinical evidences about the safety and efficacy of this procedure are anticipated.
引用
- Wang M, He Q, Yao C, et al. Treatment of High Surgical Risk Thoracoabdominal Aortic Aneurysms with Stent Graft and Multilayer Bare Stents Joint Technique: Mid-Long-Term Clinical Results. Ann Vasc Surg. 2019. PMID: 31536795. doi:10.1016/j.avsg.2019.06.041