Candy-Plug II 代假腔封堵器治疗慢性主动脉夹层的可行性与早期结果
本研究评估了使用Candy-Plug II代(CP II)封堵慢性主动脉夹层假腔的早期结果。平均随访8个月,9例复查CTA中8例出现主动脉重塑,1例动脉瘤囊稳定。CP II简化了操作步骤并提供了良好的密封效果,死亡率和并发症率低。
要点
- CP II技术成功率为100%,临床成功率为93%。
- 无术中并发症,1例死于与CP II无关的逆行性A型主动脉夹层。
- 平均随访8个月,8/9例复查患者出现主动脉重塑。
核心结论
- CP II降低了操作步骤数量并提供良好的密封,死亡率和并发症率低,主动脉重塑率高。
主要发现
- 技术成功率为100%,临床成功率为93%。
- 1例患者因最终造影显示持续性假腔反流而需要术中额外行假腔栓塞,但CP II中心无血流。
- 无术中并发症;12例患者实现即刻完全假腔封堵,另2例需要再次干预。
- 1例患者死于与CP II置入无关的逆行性A型主动脉夹层。
- 平均随访8个月(范围3-12个月),9例患者行CTA检查,其中8例有主动脉重塑证据,1例动脉瘤囊稳定。
临床怎么用
- CP II可用于慢性主动脉夹层胸段假腔封堵,简化操作并取得高技术成功率和主动脉重塑率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Purpose: To present the early results of false lumen (FL) occlusion in chronic aortic dissection using the Candy-Plug generation II (CP II), which has a self-closing fabric channel that obviates the need for separate occlusion of its center. Materials and Methods: Fourteen consecutive patients (mean age 60±11 years; 10 men) with persistent FL backflow and aneurysm formation at the thoracic segment in chronic aortic dissection underwent thoracic endovascular aortic repair (TEVAR) with FL occlusion using the refined CP II. Primary endpoints were technical success (successful deployment) and clinical success (no FL backflow at the CP II level). Secondary endpoints included 30-day mortality and morbidity and aortic remodeling during follow-up. Results: Technical success was 100%. One patient required additional intraprocedural FL embolization at the CP II level due to persistent FL backflow on final angiography (clinical success 93%), though there was no flow through the CP II center. There were no intraprocedural complications. Immediate complete FL occlusion was achieved in 12 patients; the other 2 required reintervention. One had contrast enhancement in the distal FL proximal to the CP II and was treated with coil embolization. The other patient had persistent type I endoleak at the level of the left subclavian artery (LSA) and underwent left carotid-LSA bypass and proximal stent-graft extension. One patient died due to retrograde type A aortic dissection that was not related to CP II placement. Over a mean 8-month follow-up (range 3-12), 9 patients had computed tomography angiography; 8 patients had evidence of aortic remodeling, while 1 aneurysm sac was stable. Conclusion: The CP II reduces the number of procedural steps and offers good seal, with minimal morbidity and mortality and a high rate of aortic remodeling.
引用
- Eleshra A, Kölbel T, Tsilimparis N, et al. Candy-Plug Generation II for False Lumen Occlusion in Chronic Aortic Dissection: Feasibility and Early Results. J Endovasc Ther. 2019. PMID: 31478456. doi:10.1177/1526602819871613
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。