文献速递主动脉疾病

术中超声造影检测复杂及肾下腹主动脉腔内修复术后内漏

Intraoperative contrast-enhanced ultrasound examination for endoleak detection after complex and infrarenal endovascular aortic repair.
PubMed 文献 · J Vasc Surg · 2019-09-03

iCEUS检出全部8例造影发现的II型内漏,另检出8例造影未见的II型内漏(P = .002),出院前CTA仅5例持续存在。iCEUS可作为减少造影剂和辐射暴露的辅助手段。

要点

  • iCEUS可检出造影遗漏的II型内漏(8例,P = .002)
  • iCEUS能明确所有内漏的起源
  • 出院前CTA仅31%的iCEUS检出内漏持续存在

核心结论

  • iCEUS可作为EVAR术中减少造影剂和辐射暴露的辅助检查手段
  • 对于肾下EVAR及内漏IV型或V型血管腔内修复,可考虑以iCEUS替代完成期造影

研究设计与样本

  • 手术类型:开窗和/或分支EVAR 14例(66%),肾下EVAR 5例(24%),肾下EVAR加双侧髂动脉侧支植入1例(5%),肾下EVAR加髂内动脉封堵器植入1例(5%)
  • 所有患者先完成造影内漏检测,再由对造影结果设盲的同一检查者行iCEUS

主要发现

  • 造影检出8例II型内漏,其中4例明确内漏起源
  • iCEUS检出全部8例造影可见的II型内漏,另检出8例造影未见的II型内漏(P = .002),并明确所有病例的内漏起源
  • 出院前CTA(中位时间5天,范围1-7天)显示iCEUS检出的16例II型内漏中仅5例持续存在(31%,P = .002)

临床怎么用

  • 在EVAR术中完成造影后可行iCEUS检测内漏,以减少造影剂和辐射暴露
  • 对于肾下EVAR及内漏IV型或V型修复,可考虑以iCEUS替代完成期造影

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The aim of this pilot study was to evaluate intraoperative contrast-enhanced ultrasound (iCEUS) examination for endoleak (EL) detection after complex endovascular aortic repairs (EVAR) in comparison with the standard angiographic completion control. METHODS: Twenty-one patients (16 male; median age, 73 years [range, 54-81 years]) who underwent single-stage EVARs at our center between October 2016 and October 2018 were included prospectively. The procedures comprised fenestrated and/or branched EVAR (n = 14; 66%), infrarenal EVAR (n = 5; 24%), infrarenal EVAR with bilateral iliac side branch implantation (n = 1; 5%), and infrarenal EVAR with occluder implantation into the internal iliac artery (n = 1; 5%). The used endografts included 14 custom made devices (Cook, Australia Pty Ltd, Brisbane, Australia, n = 6; Vascutek Terumo, Glasgow, Scotland, n = 8) and seven standard infrarenal endografts (Medtronic Inc, Santa Rosa, Calif, n = 5; Vascutek Terumo, Glasgow, Scotland, n = 1; Cook, n = 1). All patients underwent an angiographic completion control for EL detection followed by iCEUS examination. The iCEUS examination was performed by the same examiner who was blinded to the angiography result. In addition to the comparison of the angiographic results to iCEUS examination, iCEUS examination was also compared with the computed tomography angiography (CTA) before discharge (median time to CTA, 5 days [range, 1-7 days]). RESULTS: Angiography detected eight type II EL, defining the EL origin in four cases. In addition to detecting all of those eight EL, iCEUS examination revealed eight more type II EL not seen on angiography (P = .002) and allowed a definition of the EL origin in all cases. CTA before discharge showed a persistence of only 5 of the 16 type II EL detected by iCEUS examination (31%, P = .002). CONCLUSIONS: An iCEUS examination can be used as another adjunct to decrease exposure to contrast agent and radiation during EVAR, including complex procedures. A replacement of the completion angiography by iCEUS examination is conceivable for infrarenal EVAR, but also for endovascular type IV or type V repairs. Future studies with larger patient numbers will help to further validate iCEUS examination during complex EVAR.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Keschenau PR, Alkassam H, Kotelis D, et al. Intraoperative contrast-enhanced ultrasound examination for endoleak detection after complex and infrarenal endovascular aortic repair. J Vasc Surg. 2019. PMID: 31492615. doi:10.1016/j.jvs.2019.07.060

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。