文献速递主动脉疾病血液透析通路

经皮腋动脉入路在复杂主动脉介入中的安全性与有效性

Safety and Effectiveness of Percutaneous Axillary Artery Access for Complex Aortic Interventions.
PubMed 文献 · Ann Vasc Surg · 2019-08-05

本研究评估了复杂主动脉介入中经皮腋动脉大鞘入路的安全性和有效性。46例患者中技术成功率为89%(41/46),5例因持续出血置入覆膜支架,2例(4%)出现入路相关神经并发症。结论认为该入路安全有效,并发症率低且与学习曲线相关。

要点

  • 经皮腋动脉大鞘入路技术成功率为89%(41/46)。
  • 入路相关并发症率为4%(2/46),均为同侧上肢感觉异常。
  • 5例因持续出血于 index operation 中置入覆膜支架止血。

核心结论

  • 经皮腋动脉入路可为复杂主动脉介入提供上肢大鞘动脉通路,安全性和技术成功率高。
  • 总体并发症率低,且主要发生在早期经验阶段,提示存在学习曲线效应。

研究设计与样本

  • 连续纳入在FDA批准的医师发起IDE研究内行血管内胸腹主动脉瘤修复,或其他复杂主动脉介入中行内脏动脉介入的患者。
  • 所有患者均接受超声引导下经皮腋动脉穿刺,并在置入大鞘前部署2枚Perclose ProGlide装置。
  • 共46例患者接受经皮腋动脉入路。

主要发现

  • 最大鞘管型号:16F 1例(2%),12F 42例(91%),10F 1例(2%),9F 1例(2%),8F 1例(2%)。
  • 技术成功率为89%(41/46),定义为止血性动脉闭合且无需要干预的腋动脉狭窄或闭塞。
  • 5例患者需要在 index operation 中置入血管内覆膜支架以控制持续性的入路部位出血。
  • 2/46例(4%)发生入路相关并发症,均为同侧上肢感觉异常无运动无力,其中1例持续手指麻木。

关键数值与推荐

  • 技术成功定义为止血性动脉闭合且无证据显示需要干预的腋动脉狭窄或闭塞。

临床怎么用

  • 经皮腋动脉入路可用于复杂主动脉介入中需要上肢大鞘通路的情况,避免外科切开和动脉导管可减少手术时间和伤口相关并发症。

局限性

  • 并发症主要发生在早期经验阶段,提示学习曲线效应,可能影响结果的外推。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study is to evaluate the safety and effectiveness of percutaneous axillary artery access in patients requiring upper extremity large sheath access during complex aortic interventions. METHODS: Consecutive patients who had percutaneous axillary artery access with a large-bore sheath during endovascular thoracoabdominal aortic artery aneurysm repair within an Food and Drug Administration-approved, physician-sponsored investigational device exemption study or visceral artery interventions during other complex aortic interventions were included in the study. All patients had percutaneous axillary artery ultrasound-guided access and deployment of 2 Perclose ProGlide devices (Abbott Vascular, Santa Clara, CA) prior to introduction of a large sheath. Completion angiography was performed to assess technical success of percutaneous access site closure, which was defined as hemostatic arterial closure without evidence of axillary artery stenosis or occlusion requiring intervention. Follow-up computed tomography scans and patient records were also reviewed for access site associated complications. RESULTS: A total of 46 patients underwent percutaneous axillary artery access. Largest sheath profile was 16F in 1 (2%), 12F in 42 (91%), 10F in 1 (2%), 9F in 1 (2%), and 8F in 1 (2%) patient. Technical success was achieved in 41 of 46 patients (89%). Five patients required endovascular covered stent placement during the index operation to control persistent access site bleeding. Two of 46 patients (4%) suffered access-related complications; both patients experienced ipsilateral upper extremity paresthesias without motor weakness, with persistent digit numbness in one. There was no incidence of conversion to open axillary artery repair and no additional access site complications (stenosis, occlusion, or dissection) but neurologic complications were observed during follow-up. CONCLUSIONS: Percutaneous axillary artery access can be used to provide upper extremity arterial access during complex aortic interventions with high rates of safety and technical success. Overall complication rates are low and occurred mainly during the early experience, indicating that there is an associated learning curve effect. Elimination of surgical cutdown incisions and arterial conduits by using percutaneous axillary access may reduce operative times and wound-related complications during complex aortic interventions requiring large-bore upper extremity access.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Agrusa CJ, Connolly PH, Ellozy SH, et al. Safety and Effectiveness of Percutaneous Axillary Artery Access for Complex Aortic Interventions. Ann Vasc Surg. 2019. PMID: 31394224. doi:10.1016/j.avsg.2019.05.046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。