文献速递主动脉疾病

主动脉弓TEVAR中远端烟囱后密封环短于10mm与内漏相关

A Shorter Aortic Arch Sealing Ring (< 10 mm) Distal to the Most Distal Chimney Seems to Be an Additional Important Factor Contributing to a Gutter Endoleak in Aortic Arch TEVAR.
PubMed 文献 · Ann Vasc Surg · 2019-08-06

本研究回顾2010-2018年45例因主动脉弓病变行烟囱技术TEVAR患者的影像与临床资料,探讨预测内漏的解剖与技术参数。8例(17.8%)术后出现Ia型内漏,所有内漏患者均使用2个烟囱且远端烟囱后密封环短于10mm或无密封环,与较长密封区患者差异有统计学意义(P=0.043)。结论提示远端烟囱后密封环超过10mm可能与降低Ia型内漏风险相关。

要点

  • 远端烟囱后密封环长度<10mm与Ia型内漏发生相关(P=0.043)。
  • 术后Ia型内漏发生率为17.8%(8/45),随访期未发现晚期内漏。
  • 支架放大率、近远端锚定区直径及主动脉直径与内漏无关。

核心结论

  • 远端烟囱后密封环超过10mm似乎与降低Ia型内漏风险相关。

研究设计与样本

  • 单中心回顾性研究,纳入2010-2018年45例因主动脉弓病变行烟囱技术TEVAR的患者。

主要发现

  • 8例(17.8%)术后计算机断层扫描血管造影发现Ia型内漏,随访期未检出晚期Ia型内漏。
  • 所有术后Ia型内漏患者均使用2个烟囱(分别置于头臂干和左颈总动脉),且远端烟囱后密封环无或短于10mm,与密封区较长患者差异有统计学意义(P=0.043)。
  • 内漏患者与非内漏患者在支架放大率、近远端锚定区直径及病变近端主动脉直径方面无差异。

关键数值与推荐

  • 远端烟囱后密封环超过10mm与Ia型内漏风险降低相关(P=0.043)。

临床怎么用

  • 主动脉弓烟囱TEVAR术中,应尽量保证远端烟囱后密封环超过10mm以降低Ia型内漏风险。

局限性

  • 样本量相对较少且为单中心研究,需更大规模研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of the present study was to define the possible anatomical and technical parameter that might predict the occurrence of gutter endoleak or type Ia endoleak (EL Ia) in patients treated with the chimney graft (CG) technique for the brachiocephalic trunk (BCT) and left common carotid artery (LCCA) due to aortic arch pathologies. METHODS: We reviewed our institutional endovascular aortic database of patients, who between 2010 and 2018 had undergone thoracic endovascular aortic repair (TEVAR) with chimney graft technique (ChTEVAR) as a debranching method of the supraaortic arteries. RESULTS: ChTEVAR was performed in 45 patients of whom a chimney in both the LCCA and the BCT was used in 32 patients, only in the LCCA in twelve patients, and only in the BCT in one patient. Eight patients (17.8%) had an EL Ia (based on postoperative computed tomography angiography). No late EL Ia was detected during the follow-up period. All patients with a postoperative EL Ia received 2 CGs with one each for the BCT, and LCCA had either no or a sealing ring distal to the most distal chimney of less than 10 mm versus patients with a longer sealing zone (P = 0.043). Patients with an endoleak did not differ from those without endoleak with respect to stent-graft oversizing, the diameter of the proximal and distal landing zones, or the aortic diameter directly proximal to the pathology. CONCLUSIONS: A sealing ring distal to the most distal chimney of more than 10 mm seems to be associated with a reduced risk of an EL Ia. The relatively few patients and the single-center nature require larger studies to verify the present results.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Ahmad W, Buse C, Kröger JR, et al. A Shorter Aortic Arch Sealing Ring (< 10 mm) Distal to the Most Distal Chimney Seems to Be an Additional Important Factor Contributing to a Gutter Endoleak in Aortic Arch TEVAR. Ann Vasc Surg. 2019. PMID: 31394247. doi:10.1016/j.avsg.2019.05.065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。