内血管瘤封闭及烟囱内血管瘤封闭治疗EVAR后Ia型与III型内漏
所有患者技术成功,中位随访13.5个月无腹主动脉瘤相关死亡或血管并发症,2例需再干预。结论认为EVAS及烟囱EVAS治疗EVAR后Ia型和III型内漏技术可行,短期随访安全有效。
要点
- EVAS及烟囱EVAS治疗EVAR后Ia型和III型内漏技术可行。
- 2例因持续II型和Ia型内漏需再干预,栓塞治疗成功。
核心结论
- EVAS和烟囱EVAS治疗EVAR及烟囱EVAR后Ia型和III型内漏技术可行。
- 短期随访提示该技术是处理失效EVAR的安全有效替代方案。
研究设计与样本
- 技术成功定义为术中完成造影示Nellix内移植物成功封闭且内脏血管通畅。
主要发现
- EVAR至EVAS中位时间41.5个月(29-81.8)。
- 8例择期手术,2例急诊手术;4例置入烟囱移植物,6例行经典EVAS。
- 中位手术时间222.5分钟(138.8-418.8),所有患者技术成功。
- EVAS后中位住院7天(6.8-14),中位随访13.5个月(6.3-25.5)无腹主动脉瘤相关死亡或血管并发症。
- 2例因持续II型和Ia型内漏需再干预,栓塞治疗成功。
临床怎么用
- 对于EVAR后出现Ia型或III型内漏且不宜常规再干预的患者,可考虑EVAS或烟囱EVAS作为替代方案。
- 术中完成造影确认Nellix内移植物封闭成功且内脏血管通畅是技术成功的关键。
- 术后需随访监测内漏持续或复发,必要时行栓塞再干预。
局限性
- 随访时间短(中位13.5个月)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The aim of this study was to report the treatment of type Ia and type III endoleaks after endovascular aneurysm repair (EVAR) or chimney EVAR using endovascular aneurysm sealing (EVAS) and chimney EVAS. METHODS: Ten consecutive patients who underwent the EVAS procedure to treat endoleaks after EVAR were retrospectively included between July 2015 and July 2017. Technical success of EVAS was defined as a successful sealing of the Nellix endograft with visceral vessel patency on intraoperative completion angiography. RESULTS: The median time between EVAR and EVAS procedure was 41.5 months (29-81.8). Eight patients had an elective procedure, whereas 2 were treated in emergency. Chimney endografts were placed during the EVAS procedure in 4 patients, whereas classic EVAS was performed for the other 6 patients. The median procedural time was 222.5 min (138.8-418.8). The technical success was achieved for all patients. The median length of stay after EVAS was 7 days (6.8-14). No death related to abdominal aortic aneurysms or vascular complications were reported for a median follow-up duration of 13.5 months (6.3-25.5). A reintervention was required for 2 patients who developed persistent type II and type Ia endoleaks, which were successfully treated using an embolization procedure. CONCLUSIONS: EVAS and chimney EVAS in the treatment of type Ia and type III endoleaks after EVAR and chimney EVAR are technically feasible. Short-term follow-up suggests that the procedure is a safe and efficient therapeutic alternative to manage disabled EVAR.
引用
- Lareyre F, Mialhe C, Dommerc C, et al. Endovascular Aneurysm Sealing and Chimney Endovascular Aneurysm Sealing in the Treatment of Type Ia and Type III Endoleaks After Endovascular Aneurysm Repair. Ann Vasc Surg. 2019. PMID: 31394252. doi:10.1016/j.avsg.2019.05.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。