不同覆膜支架系统在EVAR术后的血流动力学差异
本研究基于32例EVAR术后患者的CT数据,等分四组比较AFX、Endurant、Excluder和Nellix支架的流速、壁面剪切应力(WSS)和螺旋度。结果显示不同支架在血流分叉前后诱导不同血流动力学条件,Nellix最高流速和WSS,Endurant最低WSS但保留高螺旋度。
要点
- 不同覆膜支架在血流分叉处诱导不同血流动力学条件。
- Nellix诱导最高流速和WSS,Endurant最低WSS但螺旋度高。
- AFX和Excluder材料相同,血流动力学条件相似。
核心结论
- 不同覆膜支架类型在血流分叉周围诱导可变的血流动力学条件,Nellix的平行分支结构在流速和WSS方面似乎有利,但血流分叉前螺旋流被抑制。
研究设计与样本
- 使用32例患者的CT数据,等分四组(AFX、Endurant、Excluder、Nellix),计算流速、WSS和螺旋度统计量,比较组间和组内差异。
主要发现
- 术前AAA形态在四组间无显著差异。
- AFX和Nellix组螺旋度水平低,Endurant和Excluder组高。
- 血流分叉后趋势保持,Nellix诱导最高流速和WSS,Excluder和AFX紧随其后。
- AFX(p<0.001,R2=0.09)和Nellix(p<0.001)组血流分叉前后螺旋度显著增加。
临床怎么用
- 临床选择覆膜支架时需考虑不同支架的血流动力学特性,高WSS通常被认为是有利的,而螺旋度极端(极低或高)可能是不利信号。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The implication of haemodynamics in the occurrence of complications after endovascular aneurysm repair (EVAR) has been raised in the literature. Different aortic stent graft configurations may lead to different haemodynamic properties. The current study deals with the post-operative haemodynamic variability between four stent graft systems with different structure, material, and type of fixation. METHODS: Computed tomography data of 32 patients were used, equally distributed among the four endograft groups, namely the AFX, Endurant, Excluder, and Nellix. Velocity, wall shear stress (WSS), and helicity statistics were calculated, in regions around the flow division where disturbances are expected. The haemodynamic data were compared between and within the groups. RESULTS: The morphology of AAAs pre-operatively did not vary significantly among the four groups. Before the flow division, lowest velocity was observed in Endurant cases and highest in Nellix cases. Endurant induced the lowest peak WSS and Nellix the highest (p = .03). The helicity levels were low in AFX and Nellix cases and high in Endurant and Excluder cases. After the flow division, the trend in the results was preserved. Nellix induced the highest velocity and WSS, followed closely by Excluder and AFX. There was a significant increase of helicity before and after flow division in AFX (p <0.001, R2 = 0.09) and Nellix (p <0.001) cases. CONCLUSIONS: It has been shown that different types of endografts induce variable haemodynamic conditions around the flow division. The parallel limb structure, featured by Nellix, seems to induce favourable flow conditions in terms of velocity and WSS, while helical flow before the flow division is suppressed. High WSS is generally considered to be a desirable flow characteristic in endovascular devices, whereas helicity extremes (very low or high) are potentially a negative sign. Endurant, with the stiffer material and the short neck structure, was associated with the lowest blood velocity and WSS values but preserved high helicity levels. The AFX and Excluder, which include the same material, induced similar haemodynamic conditions.
引用
- Raptis A, Xenos M, Spanos K, et al. Endograft Specific Haemodynamics After Endovascular Aneurysm Repair: Flow Characteristics of Four Stent Graft Systems. Eur J Vasc Endovasc Surg. 2019. PMID: 31431336. doi:10.1016/j.ejvs.2019.04.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。