文献速递主动脉疾病

升主动脉人工血管置换对降主动脉周向应变的即时影响

Immediate Impact of Prosthetic Graft Replacement of the Ascending Aorta on Circumferential Strain in the Descending Aorta.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2019-08-21

结果显示置换后降主动脉周向应变和扩张性显著增加,且囊性中层坏死患者术后应变更高,提示人工血管可能增强能量向远端主动脉传递。

要点

  • 升主动脉置换后降主动脉周向应变即刻增加,扩张性也增加。
  • 囊性中层坏死患者术后周向应变显著高于动脉粥样硬化性动脉瘤患者。
  • 应变增加与每搏输出量、左室射血分数及脉压变化无关。

核心结论

  • 升主动脉人工血管置换可即刻增加降主动脉周向应变,尤其在囊性中层坏死患者中更明显,提示人工血管可能增强能量向远端主动脉传递。

主要发现

  • 置换后降主动脉周向应变从6.3 ± 2.8%增至8.9 ± 3.4%(p = .001),扩张性从5.7 [3.7-8.6] 10-3 mmHg增至8.5 [6.4-12.4] 10-3 mmHg(p < .001)。
  • 术后左室射血分数轻度增加(52.3 ± 10.8% vs. 55.0 ± 11.9%,p < .001),但每搏输出量无显著变化(p = .41)。
  • 应变增加幅度与每搏输出量变化(r = -.03,p = .86)、左室射血分数变化(r = .18,p = .28)及脉压变化(r = .28,p = .06)均无显著相关性。
  • 降主动脉尺寸术前术后无显著差异:舒张末期面积4 [2.7-4.6] cm2 vs. 3.7 [2.5-5] cm2(p = .89),收缩末期面积4.3 [3.2-5.3] cm2 vs. 4.5 [3.3-5.8] cm2(p = .14)。
  • 亚组分析中,囊性中层坏死患者术后周向应变显著高于动脉粥样硬化性动脉瘤患者(9.7 ± 3.5% vs. 7.0 ± 2.3%,p = .03)。

临床怎么用

  • 升主动脉人工血管置换术后应关注降主动脉的应变变化,尤其对囊性中层坏死患者,可能需加强远端主动脉的影像随访。

局限性

  • 本研究为初步研究,样本量有限,仅评估术中即时变化,缺乏长期随访数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Prosthetic replacement of the ascending aorta (AA) can potentially modify energy propagation to the distal aorta and contribute to adverse aortic remodelling. This preliminary study employed intra-operative transoesophageal echocardiography (TOE) to assess the immediate impact of prosthetic graft replacement of the AA on circumferential strain in the descending aorta. METHODS: Intra-operative TOEs in patients undergoing AA graft replacement were analysed for circumferential strain, fractional area change (FAC), dimensions (end diastolic area [EDA], and end systolic area [ESA]) in the descending aorta immediately before and after graft replacement. Deformation was assessed via global peak circumferential aortic strain (CAS), together with pulse pressure corrected strain, time to peak strain (TTP), and aortic distensibility. RESULTS: Forty-five patients undergoing AA replacement with prosthetic graft (91% elective) were studied. Following grafting, descending thoracic aortic circumferential strain increased (6.3 ± 2.8% vs. 8.9 ± 3.4%, p = .001) paralleling distensibility (5.7 [3.7-8.6] 10-3 mmHg vs. 8.5 [6.4-12.4] 10-3 mmHg, p < .001). Despite slight increments in post graft left ventricular ejection fraction (LVEF) (52.3 ± 10.8% vs. 55.0 ± 11.9, p < .001), stroke volume was similar (p = .41), and magnitude of increased strain did not correlate with change in stroke volume (r = -.03, p = .86), LVEF (r = .18, p = .28), or pulse pressure (r = .28, p = .06). Descending aortic size (EDA 4 [2.7-4.6] cm2vs. 3.7 [2.5-5] cm2, p = .89; ESA 4.3 [3.2-5.3] cm2vs. 4.5 [3.3-5.8] cm2, p = .14) was similar pre- and post graft. In subgroup analysis, patients with cystic medial necrosis had a significantly higher post procedure CAS than patients with atherosclerotic aneurysms (9.7 ± 3.5% vs. 7.0 ± 2.3%, p = .03). CONCLUSIONS: Prosthetic graft replacement of the AA increases immediate aortic circumferential strain of the descending aorta, particularly in patients with cystic medial necrosis. Our findings suggest that grafts augment energy transfer to the distal aorta, a potential mechanism for progressive distal aortic dilation and/or dissection.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Rong LQ, Palumbo MC, Rahouma M, et al. Immediate Impact of Prosthetic Graft Replacement of the Ascending Aorta on Circumferential Strain in the Descending Aorta. Eur J Vasc Endovasc Surg. 2019. PMID: 31445862. doi:10.1016/j.ejvs.2019.05.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。