文献速递主动脉疾病内脏/肾动脉与血管畸形

Gore Viabahn VBX球囊扩张式覆膜支架作为桥接支架在开窗/分支型主动脉腔内修复术中的初步经验

First/Preliminary Experience of Gore Viabahn Balloon-Expandable Endoprosthesis as Bridging Stent in Fenestrated and Branched Endovascular Aortic Repair.
PubMed 文献 · Ann Vasc Surg · 2019-07-31

本研究前瞻性收集2018年4月至6月接受开窗/分支型主动脉腔内修复术并使用VBX作为桥接支架连接开窗/分支至目标内脏血管的患者,评估技术成功率和TVV相关不良事件。

要点

  • 初步结果显示VBX相关TVV不良事件发生率低,无TVV闭塞或再干预。
  • 需更大样本量和更长随访验证初步结果。

核心结论

  • 根据初步结果,Gore Viabahn VBX球囊扩张式覆膜支架可安全用作开窗或分支型主动脉腔内修复术的桥接支架。

研究设计与样本

  • 前瞻性收集2018年4月至6月接受开窗/分支型主动脉腔内修复术并使用VBX作为桥接支架的患者,分析其解剖、手术和术后数据。

主要发现

  • 共60个目标内脏血管(腹腔干14、肠系膜上动脉13、肾动脉30、髂内动脉3)通过开窗(51)、分支(7)和扇形凹槽(2)重建,其中40个(67%)使用VBX桥接。
  • 术中检测到1例肾动脉开窗相关的III型内漏,通过附加喇叭口操作成功封闭。
  • 术后第5天,1个VBX(1/40,2.5%)在分支重建的肾动脉中失去密封,需要再干预并使用自膨式覆膜支架内衬。
  • 30天内及6个月随访后无TVV闭塞或再干预发生。

临床怎么用

  • 对于开窗/分支型主动脉腔内修复术中的目标内脏血管桥接,VBX可作为备选桥接支架,但需注意分支重建中的密封失效风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study is to evaluate the preliminary outcomes of the Gore® Viabahn® balloon-expandable endoprosthesis (VBX) as bridging stent for fenestrated/branched aortic endograft. METHODS: Between April and June 2018, patients undergoing fenestrated and branched-endovascular aortic repair were prospectively collected. Anatomical, procedural, and postoperative data of patients treated with VBX as bridging stents to connect fenestrations/branches to target visceral vessels (TVVs) were analyzed. Technical success and any TVV-related adverse event were assessed before discharge, at 30 days, and after 6 months of follow-up. RESULTS: Fifteen patients undergoing fenestrated and branched-endovascular aortic repair for juxta/pararenal aneurysms (11), proximal type I endoleak after endovascular aortic repair (1), and thoracoabdominal aneurysms (3) were included in the study. Overall, 60 TVVs-celiac trunk (n = 14), superior mesenteric artery (n = 13), renal arteries (n = 30), hypogastric artery (n = 3)-were accommodated by fenestrations (n = 51), branches (n = 7), and scallops (n = 2). The bridging stent graft was a VBX in 40 (67%) TVVs. A renal artery dissection was successfully managed by a self-expandable bare metal stent. Overall, relining of a bridging stent graft was required in 2 TVVs revascularized by fenestrations (superior mesenteric artery: n = 1, renal artery: n = 1). One intraoperative type III endoleak from renal fenestration was detected and successfully sealed by an adjunctive flaring maneuver. Technical success was achieved in all cases. At 5-day, 1 VBX (1/40: 2.5%) lost its sealing in a renal artery revascularized by a branch (type II thoracoabdominal aortic aneurysm) and required reintervention and relining with a self-expandable stent graft. No TVV occlusion or reintervention occurred <30 days or after 6 months of follow-up. CONCLUSIONS: According to these preliminary results, the Gore Viabahn VBX balloon-expandable endoprosthesis can be safely used as bridging stent graft for fenestrated or branched endografts. A longer follow-up with a larger case load is necessary in order to validate this preliminary experience.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Gallitto E, Faggioli G, Pini R, et al. First/Preliminary Experience of Gore Viabahn Balloon-Expandable Endoprosthesis as Bridging Stent in Fenestrated and Branched Endovascular Aortic Repair. Ann Vasc Surg. 2019. PMID: 31376538. doi:10.1016/j.avsg.2019.04.049

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。