平行支架全腔内修复近端术后夹层性胸腹主动脉瘤
本研究回顾性分析21例近端修复术后残留夹层性胸腹主动脉瘤患者,采用平行支架全腔内修复。技术成功17例,随访无死亡或I/III型内漏,主动脉直径缩小,分支动脉通畅率较高,但需长期大样本验证。
要点
- 平行支架全腔内修复夹层性TAAA技术成功率高,短期效果可。
- 随访中无死亡及I/III型内漏,假腔血栓化比例高。
- 分支动脉累积通畅率12个月97.3% vs 100%,18个月91.2% vs 100%。
核心结论
- 平行支架全腔内修复可作为近端术后夹层性胸腹主动脉瘤的有效替代方案。
研究设计与样本
- 回顾性研究纳入21例(男17例,平均年龄64.0±12.5岁)近端修复术后夹层性TAAA患者,2014-2016年行平行支架全腔内修复。
主要发现
- 技术成功17/21例,因术中4例I型内漏未达技术成功。
- 共重建70条分支动脉,14条腹腔干有意覆盖未重建。
- 随访平均16.2±6.1个月,无死亡及I/III型内漏,2例II型内漏。
- 70条目标分支动脉中3条(4.3%)随访期闭塞;逆向与顺行重建分支动脉12个月累积通畅率97.3% vs 100%,18个月91.2% vs 100%。
临床怎么用
- 对于近端修复术后残留夹层性TAAA,可考虑平行支架全腔内修复作为治疗选择。
局限性
- 回顾性设计、样本量小(21例)、随访时间短(平均16.2个月),需长期大样本研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Purpose: To evaluate the safety and efficacy of total endovascular repair with parallel stent-grafts for postoperative residual dissection thoracoabdominal aortic aneurysm (TAAA). Materials and Methods: A retrospective study was undertaken of 21 patients (mean age 64.0±12.5 years; 17 men) undergoing total endovascular therapy with parallel stent-grafts for postdissection TAAA after prior proximal repair between 2014 and 2016. The preoperative minimum true lumen diameter was 12.3±4.8 mm and the mean extent of dissection was 248.1±48.2 mm. Pre-, intra-, and postoperative medical records were reviewed to assess technical success, spinal cord ischemia, patency of target branch arteries, endoleak, and short-term outcomes of this approach. Results: Technical success was achieved in 17 of 21 patients owing to 4 type I endoleaks at the end of the procedures. A total of 70 branch arteries were revascularized and 14 celiac trunks were covered intentionally without reconstruction. Of 7 intraoperative endoleaks, 2 were managed intraoperatively and 5 (4 type I and 1 type II) disappeared spontaneously within 1 month. No spinal cord or abdominal organ or limb ischemia was observed. Mean follow-up was 16.2±6.1 months. No death or type I or III endoleak occurred during the follow-up; 2 type II endoleaks were observed. Nineteen of the 21 false lumens thrombosed, and the total aortic diameter decreased (57.3±8.4 to 55.3±7.4 mm, p<0.01). Three (4.3%) of 70 target branch arteries occluded during follow-up. The cumulative patency of retrogradely and antegradely revascularized branch arteries was 97.3% vs 100% at 12 months and 91.2% vs 100% at 18 months. Conclusion: Total endovascular therapy with parallel stent-grafts could be an effective alternative in treating postdissection TAAA. Further studies with long-term follow-up and larger sample size are recommended to evaluate the technique.
引用
- Liu J, Li Z, Feng J, et al. Total Endovascular Repair With Parallel Stent-Grafts for Postdissection Thoracoabdominal Aneurysm After Prior Proximal Repair. J Endovasc Ther. 2019. PMID: 31364463. doi:10.1177/1526602819863779
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。