烟囱移植物治疗近肾主动脉瘤的中期形态学CTA评估

CTA Assessment of Midterm Morphological Changes to Chimney Grafts Used in the Treatment of Juxtarenal Aortic Aneurysms.
PubMed 文献 · J Endovasc Ther · 2019-07-08

平均随访34.9个月,主动脉支架移植物平均迁移小于5 mm(2.76±2.4 mm),瘤囊直径平均缩小3.25 mm(p=0.048),右肾动脉角度上移6.72°(p=0.025)而右肾烟囱支架下移7.83°(p=0.042)。无I/III型内漏或烟囱闭塞,烟囱移植物倾向呈斜行而非平行构型但无相关临床后果。

要点

  • ch-EVAR术后中期主动脉支架移植物平均迁移<5 mm,瘤囊显著缩小。
  • 烟囱移植物随访中易呈斜行构型,但无内漏或闭塞等相关临床后果。
  • 右肾动脉角度及烟囱支架角度变化显著,左肾侧变化无统计学意义。

核心结论

  • ch-EVAR中期形态学评估显示瘤囊显著缩小,腹部装置3年位置稳定,多数病例主动脉支架移植物平均下移<5 mm。
  • 烟囱移植物随访中倾向于呈斜行而非平行构型,但无相关临床后果。

研究设计与样本

  • 基于CTA测量主动脉支架移植物迁移、目标血管角度和烟囱角度,比较系列扫描间的变化。

主要发现

  • 平均随访34.9个月(范围24-69.2个月)期间,主动脉支架移植物平均迁移为2.76±2.4 mm,每年平均迁移距离1.15 mm。
  • 动脉瘤直径平均缩小3.25 mm(p=0.048)。
  • 右肾动脉角度显著上移6.72°(p=0.025),右肾烟囱支架显著下移7.83°(p=0.042)。
  • 左肾动脉角度上移1.87°(p=0.388),相应烟囱下移5.68°(p=0.133)。
  • 研究期间未观察到I/III型内漏或烟囱闭塞。

临床怎么用

  • 对于近肾主动脉瘤ch-EVAR术后患者,中期CTA随访可评估支架迁移及瘤囊变化,烟囱斜行构型无需特殊干预。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Purpose: To evaluate chimney stent-graft position and morphological changes of the aneurysm sac as visualized by postoperative computed tomography angiography (CTA) over a minimum 24-month follow-up period. Materials and Methods: Twenty-one patients (mean age 75.7±8.6 years; 20 men) with juxtarenal aortic aneurysms who underwent successful chimney endovascular aneurysm repair (ch-EVAR) with the Endurant stent-graft and had 2 postoperative CTAs separated by at least 24 months were included in the study. CTA-based measurements of aortic stent-graft migration, target vessel angle, and chimney angle were compared between the serial scans. Results: During a mean follow-up of 34.9 months (range 24-69.2), the mean migration of the aortic stent-grafts was under 5 mm (2.76±2.4 mm). The average migration distance per year was 1.15 mm. The aneurysm diameter reduced a mean 3.25 mm (p=0.048). The right renal artery angle moved significantly upward 6.72° (p=0.025), while the right renal chimney stent-graft moved significantly downward 7.83° (p=0.042). The left renal artery angle also moved upward 1.87° (p=0.388) and the corresponding chimney moved downward 5.68° (p=0.133). During the study period, no type I/III endoleak or chimney occlusion was observed. Conclusion: Midterm morphometric assessment of ch-EVAR using CTA showed significant aneurysm sac shrinkage and a stable 3-year position of the abdominal devices, with the mean downward migration of the aortic stent-graft being <5 mm in the majority of cases. The chimney grafts seem to be prone to take an oblique rather than parallel configuration during follow-up. However, there was no relevant clinical consequence related to this phenomenon.