文献速递主动脉疾病

自制糖果塞技术封闭慢性B型主动脉夹层远端假腔

Homemade Candy Plug Using a Zenith Alpha Thoracic Stent-Graft for False Lumen Distal Occlusion in Acute-on-Chronic Type B Aortic Dissection.
PubMed 文献 · J Endovasc Ther · 2019-07-01

本病例报告描述一名50岁男性吸烟者,因快速增大的复杂性慢性B型主动脉夹层出现胸痛,近端降主动脉瘤样扩张达5.8cm。患者接受左颈动脉-锁骨下动脉搭桥、Zenith Alpha胸主动脉支架TEVAR、左颈总动脉烟囱及近端LSA栓塞后假腔仍持续血流,遂用44×125mm Zenith Alpha支架自制糖果塞封闭远端大假腔,并处理沟漏与Ia型内漏。2.5年随访显示糖果塞在位、无内漏、胸主动脉血栓化假腔缩小。

要点

  • 糖果塞技术可用于慢性主动脉夹层远端假腔的完全封闭
  • 可避免开放手术及其较高并发症风险
  • 术后需处理沟漏和Ia型内漏并长期影像随访

核心结论

  • 糖果塞技术有助于实现慢性主动脉夹层假腔的完全封闭,避免开放手术及较高并发症风险。

研究设计与样本

  • 病例报告:1例50岁男性吸烟者,复杂性慢性B型主动脉夹层,近端降主动脉瘤样扩张达5.8cm。

主要发现

  • 系列CTA显示假腔持续血流,遂采用44×125mm Zenith Alpha支架制作糖果塞封闭远端大假腔。
  • 经左肱动脉途径栓塞沟漏和Ia型内漏;2.5年时影像示糖果塞在位、无内漏、胸主动脉血栓化假腔缩小。

临床怎么用

  • 对TEVAR后假腔持续血流的慢性B型主动脉夹层,可考虑用Zenith Alpha支架自制糖果塞封闭远端大假腔。

局限性

  • 为单例病例报告,结论的普遍适用性有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Purpose: To report a candy-plug technique using a Zenith Alpha stent-graft to occlude the distal false lumen in a patient with a complicated chronic type B aortic dissection. Case Report: A 50-year-old male smoker presented with chest pain due to rapidly growing complicated chronic type B aortic dissection. Computed tomography angiography (CTA) showed the dissection extending from distal to the origin of the left subclavian artery (LSA) down to the left femoral artery. There was fusiform aneurysmal dilatation of the proximal descending aorta measuring up to 5.8 cm in diameter. He underwent left carotid-subclavian artery bypass, thoracic endovascular aortic repair with a Zenith Alpha stent-graft, a left common carotid artery chimney, and embolization of the proximal LSA. Serial CTA showed persistent false lumen flow. A decision was made to occlude the distal large false lumen using the candy-plug technique. A 44×125-mm Zenith Alpha stent-graft was used to prepare the candy plug. A gutter leak and a type Ia endoleak were embolized via a left brachial artery approach. At 2.5 years, imaging showed the candy plug in position, no endoleak, and the thrombosed false lumen in the thoracic aorta reduced in size. Conclusion: The candy-plug technique is useful in facilitating complete occlusion of the false lumen in chronic aortic dissection, which avoids an open procedure and the risk of higher morbidity.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Yap KH, Tham YC, Tay KH, et al. Homemade Candy Plug Using a Zenith Alpha Thoracic Stent-Graft for False Lumen Distal Occlusion in Acute-on-Chronic Type B Aortic Dissection. J Endovasc Ther. 2019. PMID: 31257993. doi:10.1177/1526602819860801

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。