近红外荧光成像在外周动脉疾病患者中应用的系统综述
该技术主要用于诊断、血运重建质控、截肢手术引导和血管结构可视化;诊断PAD的敏感度为67%~100%,特异度为72%~100%。结论认为该技术有前景但需进一步标准化。
要点
- 近红外荧光成像诊断PAD的敏感度67%~100%,特异度72%~100%。
- 该技术可用于诊断、血运重建质控、截肢引导和血管结构可视化。
- 血运重建前后多个荧光参数存在显著增加。
核心结论
- 近红外荧光成像可用于PAD患者的多种适应症,在诊断和手术引导方面有前景,尤其适用于现有诊断方法不适用的患者。
- 需要进一步标准化才能可靠地用于PAD患者。
主要发现
- 近红外荧光成像主要用于四个适应症:诊断、血运重建质控、截肢手术引导和血管结构可视化。
- 诊断PAD的敏感度为67%~100%,特异度为72%~100%。
- 比较血运重建前后,多个荧光参数显著增加。
关键数值与推荐
- 诊断PAD敏感度67%~100%,特异度72%~100%。
临床怎么用
- 在现有诊断方法不适用的PAD患者中,可考虑使用近红外荧光成像辅助诊断和治疗引导。
- 用于血运重建质控、截肢手术引导和血管结构可视化。
局限性
- 荧光参数未标准化,需进一步标准化才能可靠应用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: In the diagnosis of peripheral artery disease (PAD), the ankle-brachial index plays an important role. However, results of the ankle-brachial index are unreliable in patients with severe media sclerosis. Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) can provide information about tissue perfusion and has already been studied in oncologic, reconstructive, and cardiac surgery. For patients with PAD, this technique might give insight into skin perfusion and thereby guide treatment. We performed a systematic review of the literature on the use of NIR fluorescence imaging in patients with PAD. METHODS: PubMed, MEDLINE, Embase, and Cochrane were searched for articles and abstracts on the application of NIR fluorescence imaging using ICG as fluorescent dye in patients with PAD. Our search strategy combined the terms "fluorescence," "ICG," or synonyms and "peripheral artery disease" or synonyms. The extracted data included fluorescence parameters and test characteristics for diagnosis of PAD. RESULTS: Twenty-three articles were found eligible for this review using 18 different parameters for evaluation of the fluorescence signal intensity. NIR fluorescence imaging was used for four main indications: diagnosis, quality control in revascularization, guidance in amputation surgery, and visualization of vascular structures. For the diagnosis of PAD, NIR fluorescence imaging yields a sensitivity ranging from 67% to 100% and a specificity varying between 72% and 100%. Significant increases in multiple fluorescence parameters were found in comparing patients before and after revascularization. CONCLUSIONS: NIR fluorescence imaging can be used for several indications in patients with PAD. NIR fluorescence imaging seems promising in diagnosis of PAD and guidance of surgeons in treatment, especially in patients in whom current diagnostic methods are not applicable. Further standardization is needed to reliably use this modality in patients with PAD.
引用
- van den Hoven P, Ooms S, van Manen L, et al. A systematic review of the use of near-infrared fluorescence imaging in patients with peripheral artery disease. J Vasc Surg. 2019. PMID: 31230648. doi:10.1016/j.jvs.2018.11.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。