该研究在43例基线完整的无症状腹主动脉瘤患者中比较了生物力学破裂风险评估与直径指标对破裂的预测能力,随访56个月内19例破裂。结果显示破裂前9个月内生物力学指标AUC高于直径指标,6个月时高保真生物力学指标AUC为0.878,直径AUC为0.789。

要点

  • 破裂前9个月内生物力学指标预测能力优于直径指标。
  • 6个月时高保真生物力学指标AUC 0.878,直径AUC 0.789。
  • 生物力学评估可降低治疗中的假阳性率。

核心结论

  • 高保真生物力学建模提高腹主动脉瘤破裂预测能力。
  • 生物力学破裂风险指数高的无症状患者破裂风险增加。
  • 整合生物力学诊断指标可能显著降低治疗假阳性率。

研究设计与样本

  • 在两个医疗中心回顾性选取基线完整的43例无症状腹主动脉瘤患者,其中12例女性和31例男性。
  • 56个月内19例破裂,24例未破裂,结局对生物力学分析人员设盲直至分析完成。
  • 基线与1、3、6、9、12个月后分别验证生物力学和直径指标的预测能力。

主要发现

  • 破裂前9个月内生物力学风险指数的ROC曲线AUC高于直径指标。
  • 破裂前6个月差异最大:高保真生物力学AUC 0.878,低保真生物力学AUC 0.859,直径AUC 0.789,性别校正直径AUC 0.821。
  • 9个月以后的预测中无任何风险指数显示优越性。

关键数值与推荐

  • 6个月时高保真生物力学风险指数AUC为0.878。
  • 6个月时低保真生物力学风险指数AUC为0.859。
  • 6个月时直径AUC为0.789,性别校正直径AUC为0.821。

临床怎么用

  • 对无症状腹主动脉瘤患者可考虑整合生物力学破裂风险评估以改善短期破裂预测。
  • 生物力学指标有助于降低仅基于直径的治疗假阳性率。

局限性

  • 样本量较小,共43例患者。
  • 回顾性选择患者,准前瞻性设计。
  • 超过9个月的预测未显示生物力学指标优势。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Several studies of biomechanical rupture risk assessment (BRRA) showed its advantage over the diameter criterion in rupture risk assessment of abdominal aortic aneurysm (AAA). However, BRRA studies have not investigated the predictability of biomechanical risk indices at different time points ahead of rupture, nor have they been performed blinded for biomechanical analysts. The objective of this study was to test the predictability of the BRRA method against diameter-based risk indices in a quasi-prospective patient cohort study. METHODS: In total, 12 women and 31 men with intact AAAs at baseline have been selected retrospectively at two medical centers. Within 56 months, 19 cases ruptured, whereas 24 cases remained intact within 2 to 56 months. This outcome was kept confidential until all biomechanical activities in this study were finished. The biomechanical AAA rupture risk was calculated at baseline using high-fidelity and low-fidelity finite element method models. The capability of biomechanics-based and diameter-based risk indices to predict the known outcomes at 1 month, 3 months, 6 months, 9 months, and 12 months after baseline was validated. Besides common cohort statistics, the area under the curve (AUC) of receiver operating characteristic curves has been used to grade the different rupture risk indices. RESULTS: Up to 9 months ahead of rupture, the receiver operating characteristic analysis of biomechanics-based risk indices showed a higher AUC than diameter-based indices. Six months ahead of rupture, the largest difference was observed with an AUC of 0.878 for the high-fidelity biomechanical risk index, 0.859 for the low-fidelity biomechanical risk index, 0.789 for the diameter, and 0.821 for the sex-adjusted diameter. In predictions beyond 9 months, none of the risk indices proved to be superior. CONCLUSIONS: High-fidelity biomechanical modeling improves the predictability of AAA rupture. Asymptomatic AAA patients with high biomechanical AAA rupture risk indices have an increased risk of rupture. Integrating biomechanics-based diagnostic indices may significantly decrease the false-positive rate in AAA treatment. CLINICAL RELEVANCE: Rupture of abdominal aortic aneurysm (AAA) is the tenth leading cause of death in men older than 60 years; however, the currently used maximal diameter criterion has a high false-positive rate. In this study, we have compared this criterion with biomechanical rupture risk assessment on the unique data set of 43 asymptomatic AAAs, of which 19 ruptured later. Moreover, the AAA outcome was blinded to the operator for the first time. Our data demonstrated that the biomechanical rupture risk assessment is superior to maximal diameter in predicting AAA rupture up to 9 months ahead and significantly decreases the false-positive rate.