文献速递主动脉疾病

肾上固定较肾下固定与EVAR术后中期肾功能恶化相关

Suprarenal fixation is associated with worse midterm renal function after endovascular abdominal aortic aneurysm repair compared with infrarenal fixation.
PubMed 文献 · J Vasc Surg · 2019-06-24

本研究基于467例非破裂肾下腹主动脉瘤EVAR患者的前瞻性数据库,分析3年肾功能下降预测因素,并对肾上固定(SR)与肾下固定(IR)进行倾向匹配比较。

要点

  • 肾上固定是EVAR术后3年eGFR下降>20%的独立预测因素。
  • 倾向匹配后SR组3年eGFR下降17.8%,显著大于IR组的11.6%。
  • SR组急性肾损伤发生例数(10例)多于IR组(1例)。

核心结论

  • 与传统肾下固定EVAR相比,肾上固定EVAR与中期肾功能更差相关。

研究设计与样本

  • 回顾性分析2007至2014年前瞻性数据库中467例非破裂肾下腹主动脉瘤EVAR患者,排除基线透析者,纳入有3年实验室检查者237例(IR 102例,SR 135例)。
  • 采用logistic回归分析3年肾功能下降预测因素,并按年龄、性别、基线肾功能、瘤径、合并症、吸烟及可能影响肾功能的药物使用进行倾向匹配。

主要发现

  • 11例发生急性肾损伤者(IR 1例,SR 10例)被排除后续分析。
  • 倾向匹配后纳入87对(平均年龄77.2±6.3岁,男性151例[86.8%]),平均随访5.5±1.8年。

临床怎么用

  • 对于肾下腹主动脉瘤EVAR,选择固定方式时需权衡肾上固定对中期肾功能的潜在不利影响。

局限性

  • 回顾性设计,仅纳入有3年实验室检查的患者,可能存在选择偏倚。
  • 急性肾损伤患者被排除在晚期肾功能评估之外。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Several reports have indicated that suprarenal (SR) fixation may impair renal function after endovascular abdominal aortic aneurysm repair (EVAR). However, most were short-term or at most, 1-year observational studies; therefore, the midterm effects on renal function remain unclear. This study aimed to identify predictors of midterm renal dysfunction after EVAR and compare renal outcomes in patients after EVAR with SR and infrarenal (IR) fixation. METHODS: A total of 467 patients who underwent EVAR of nonruptured IR abdominal aortic aneurysm between 2007 and 2014 were reviewed in a prospectively collected database. Patients on hemodialysis at baseline were excluded. Among the remaining patients, those with 3-year laboratory testing were included in this study. Patients who developed acute kidney injury were excluded from the late renal function estimation. Predictors of 3-year renal function decline were estimated using logistic regression analysis. In addition, patients undergoing EVAR with IR (IR group) and SR fixation devices (SR group) were propensity matched by age, sex, baseline renal function, baseline aneurysm diameter, comorbidities, smoking habits, and regular use of medicines that may act on kidney function. Changes in renal function after surgery were compared between the IR group and the SR group. RESULTS: During the study period, 237 patients (102 IRs and 135 SRs) were followed up with laboratory testing 3 years after surgery. Logistic regression analysis revealed that the use of a SR fixation device was independently predictive of a more than 20% decrease in the estimated glomerular filtration rate at 3 years after EVAR (odds ratio, 2.06; 95% confidence interval, 1.18-3.58; P = .011). Eleven patients who developed acute kidney injury (1 IR and 10 SRs) were excluded from the subsequent analysis. After propensity score matching, 87 pairs were selected (mean age, 77.2 ± 6.3 years; 151 males [86.8%]). The mean follow-up duration was 5.5 ± 1.8 years. In the SR group, estimated glomerular filtration rate at 3 years after surgery decreased significantly more than that in the IR group (mean of 17.8% vs 11.6%, respectively; P = .034). CONCLUSIONS: This study suggests that, compared with EVAR with IR endograft fixation, EVAR with SR endograft fixation is associated with worse outcomes for midterm renal function.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Banno H, Ikeda S, Kawai Y, et al. Suprarenal fixation is associated with worse midterm renal function after endovascular abdominal aortic aneurysm repair compared with infrarenal fixation. J Vasc Surg. 2019. PMID: 31248765. doi:10.1016/j.jvs.2019.03.061

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。