文献速递外周动脉疾病

最大收缩期加速用于诊断和评估外周动脉疾病严重程度的血流模型研究

Using maximal systolic acceleration to diagnose and assess the severity of peripheral artery disease in a flow model study.
PubMed 文献 · J Vasc Surg · 2019-05-27

该体外循环模型研究使用脉动气动泵驱动,模拟50%、70%、80%、90%动脉狭窄,评估超声参数最大收缩期加速(ACCmax)诊断和评估外周动脉疾病(PAD)严重程度的可行性。结果显示ACCmax随狭窄程度增加而显著下降(P < .001),压力梯度显著增加(P < .001),两者强相关(R2 = 0.937),观察者间一致性极高(ICC = 0.99)。提示ACCmax可能是诊断PAD和评估其严重程度的有效无创工具,需进一步临床研究。

要点

  • ACCmax随狭窄程度增加而显著下降,与压力梯度强相关(R2 = 0.937)。
  • ACCmax观察者间一致性极高(ICC = 0.99)。
  • ACCmax可能是诊断和评估PAD严重程度的有效无创工具。

核心结论

  • ACCmax可能是诊断PAD的有效无创工具,并可能用于评估PAD严重程度。

研究设计与样本

  • 体外循环模型研究,使用脉动气动泵驱动模拟人体循环系统。
  • 模拟50%、70%、80%、90%动脉狭窄,研究超声参数(包括ACCmax)及腔内平均动脉压力梯度的变化。
  • 由两名不知晓狭窄程度的研究者测量观察者间变异。

主要发现

  • 随着狭窄程度增加,ACCmax显著下降(P < .001)。
  • 随着狭窄程度增加,压力梯度显著增加(P < .001)。
  • ACCmax与压力梯度强相关(R2 = 0.937)。
  • ACCmax的观察者间一致性极高,组内相关系数为0.99。

临床怎么用

  • ACCmax可作为诊断PAD的无创超声参数,尤其可能适用于因中膜钙化导致踝肱指数和趾压测量结果不可靠的患者。
  • ACCmax下降程度与狭窄严重程度相关,可用于评估PAD严重程度。

局限性

  • 本研究为体外血流模型研究,结果需在临床环境中进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Because of the presence of medial calcific sclerosis, both ankle-branchial index and toe pressure measures can yield misleading results when attempting to diagnose peripheral artery disease (PAD). A new ultrasound parameter, maximal systolic acceleration (ACCmax), can be an accurate tool for diagnosing PAD, including in diabetic patients. However, it has not been evaluated thoroughly. The aim of this study was to assess the feasibility of using ACCmax to diagnose and assess the severity of PAD. METHODS: The human circulatory system was simulated using an in vitro circulatory system driven by a pulsatile pneumatic pump. Arterial stenosis of various degrees (50%, 70%, 80%, and 90%) was simulated in order to investigate the change in several ultrasound parameters (including ACCmax), as well as the intraluminal mean arterial pressure gradient. In a separate set of measurements, interobserver variability was measured using two investigators who were unaware of the degree of stenosis. RESULTS: ACCmax significantly decreased (P < .001), and the pressure gradient increased (P < .001) as the degree of stenosis increased. Moreover, we found a strong correlation between ACCmax and the pressure gradient (R2 = 0.937). Finally, interobserver variability with respect to ACCmax was extremely low, with an intraclass correlation coefficient of 0.99. CONCLUSIONS: The results of this flow model study suggest that ACCmax can be a valid, noninvasive tool for diagnosing PAD. Moreover, our finding that ACCmax decreases as the severity of stenosis increases, together with the strong correlation between ACCmax and the pressure gradient, suggests that ACCmax may be useful as an alternative diagnostic tool for assessing the severity of PAD. These promising in vitro data warrant further study in a clinical setting.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Brouwers JJWM, van Doorn LP, van Wissen RC, et al. Using maximal systolic acceleration to diagnose and assess the severity of peripheral artery disease in a flow model study. J Vasc Surg. 2019. PMID: 31147131. doi:10.1016/j.jvs.2019.01.088

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。