文献速递主动脉疾病

Zenith Spiral Z与Zenith Flex髂支在EVAR中的顺应性与疗效比较

Conformability and Efficacy of the Zenith Spiral Z Leg Compared with the Zenith Flex Leg in Endovascular Abdominal Aortic Aneurysm Repair.
PubMed 文献 · Ann Vasc Surg · 2019-05-07

该回顾性研究比较了腹主动脉瘤腔内修复术(EVAR)中使用Zenith Spiral Z髂支(ZSLE)与Zenith Flex髂支(TFLE)的结局。共纳入56例患者111条髂支,随访平均43.6个月。结果显示ZSLE组3年无肢体相关并发症率显著高于TFLE组(96.1% vs 84.4%,P=0.039),且髂动脉扭曲指数变化更小(P=0.022)。

要点

  • ZSLE组3年无肢体相关并发症率显著优于TFLE组(96.1% vs 84.4%,P=0.039)。
  • ZSLE组髂动脉扭曲指数变化显著小于TFLE组(-3.0±7.9 vs -7.4±11.7,P=0.022)。
  • ZSLE作为支架移植物髂支具有更好的顺应性。

核心结论

  • 与Zenith Flex髂支相比,Spiral Z髂支的肢体相关并发症发生率更低,髂动脉扭曲指数变化更小。
  • Spiral Z髂支作为支架移植物髂支提供了更好的顺应性。

研究设计与样本

  • 共56例患者(11例女性,平均年龄78.5±5.5岁),111条髂支;TFLE组43条髂支(22例患者),ZSLE组68条髂支(34例患者)。
  • 平均随访时间43.6±27.6个月。

主要发现

  • 随访期间TFLE组发生8例肢体相关并发症,ZSLE组发生2例。
  • 3年无肢体相关并发症率TFLE组为84.4%,ZSLE组为96.1%(P=0.039)。
  • 主髂动脉扭曲指数变化两组间无统计学显著差异(TFLE vs ZSLE:-6.1±5.8 vs -4.9±6.4,P=0.324)。
  • 髂动脉扭曲指数变化两组间有显著差异(TFLE vs ZSLE:-7.4±11.7 vs -3.0±7.9,P=0.022)。

临床怎么用

  • 在EVAR中选择髂支时,Spiral Z髂支可能降低肢体相关并发症风险并减少髂动脉扭曲指数的变化。
  • 对于髂动脉扭曲明显的患者,Spiral Z髂支的更好顺应性可能具有临床优势。

局限性

  • 本研究为回顾性设计,可能存在选择偏倚。
  • 样本量较小(56例患者,111条髂支),结果需更大规模研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study is to compare the outcome of endovascular abdominal aortic aneurysm repair (EVAR) using the Zenith® Spiral Z abdominal aortic aneurysm iliac leg (ZSLE) versus the Zenith® Flex abdominal aortic aneurysm iliac leg (TFLE). METHODS: Patients undergoing EVAR using TFLE or ZSLE between October 2009 and December 2017 were retrospectively reviewed. Clinical end points were freedom from limb-related complications and change in arterial tortuosity indexes. Limb-related complication was defined as limb stenosis or occlusion, stent kink, stent disconnection, and type 1b endoleak. Tortuosity indexes were measured on the preoperative and postoperative computed tomography and compared. RESULTS: A total of 56 patients (11 female, average age 78.5 ± 5.5 years), 111 limbs, were enrolled. One patient was treated using aortouni-iliac device. TFLE was deployed in 43 limbs (22 patients) and ZSLE in 68 limbs (34 patients). Average follow-up was 43.6 ± 27.6 months. During follow-up, 8 limb-related complications occurred in the TFLE group and 2 in the ZSLE group. Freedom from limb-related complications at 3 years was 84.4% in the TFLE group and 96.1% in the ZSLE group (P = 0.039). There was no statistically significant difference between the TFLE and the ZSLE group in the aortoiliac tortuosity change (TFLE versus ZSLE -6.1 ± 5.8 vs. -4.9 ± 6.4, P = 0.324). However, there was significance in the iliac tortuosity change (-7.4 ± 11.7 vs. -3.0 ± 7.9, P = 0.022). CONCLUSIONS: Spiral Z leg showed less occurrence of limb-related complications and less iliac artery tortuosity index change compared to Zenith Flex leg. The spiral Z leg provided better conformability as a stent-graft limb.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Iwakoshi S, Nakai T, Ichihashi S, et al. Conformability and Efficacy of the Zenith Spiral Z Leg Compared with the Zenith Flex Leg in Endovascular Abdominal Aortic Aneurysm Repair. Ann Vasc Surg. 2019. PMID: 31071429. doi:10.1016/j.avsg.2019.02.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。