文献速递主动脉疾病外周动脉疾病颈动脉与弓上血管

远程缺血预适应对血管手术患者动脉僵硬度的影响:一项随机临床试验

The Effect of Remote Ischaemic Preconditioning on Arterial Stiffness in Patients Undergoing Vascular Surgery: A Randomised Clinical Trial.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2019-05-22

结果显示RIPC组与假组在增强指数、脉搏波速度等主要终点变化上无显著差异,但两组术后动脉僵硬度均显著改善。

要点

  • RIPC未显著改善血管手术患者的动脉僵硬度主要终点。
  • RIPC组与假组术后增强指数、小动脉弹性指数和平均动脉压均显著改善。
  • 术后动脉僵硬度变化可能受手术、麻醉或氧化应激等因素影响。

核心结论

  • RIPC对血管手术患者的动脉僵硬度无显著影响,但两组术后动脉僵硬度均显著改善。

研究设计与样本

  • RIPC方案为四个循环的5分钟缺血后5分钟再灌注,使用血压袖带在麻醉准备时实施。
  • 术后20-28小时测量动脉僵硬度和血流动力学参数,主要终点为增强指数和脉搏波速度。

主要发现

  • RIPC组44例和假组46例完成分析,两组基线可比。

临床怎么用

  • 血管手术患者围术期动脉僵硬度可能自然改善,RIPC不应仅以改善动脉僵硬度为目的常规使用。
  • 需进一步研究明确手术、麻醉或氧化应激对术后动脉僵硬度的影响。

局限性

  • 单中心研究,样本量有限(RIPC组44例,假组46例)。
  • 原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The main aim of this study was to evaluate the effect of remote ischaemic preconditioning (RIPC) on arterial stiffness in patients undergoing vascular surgery. METHODS: This was a randomised, sham controlled, double blind, single centre study. Patients undergoing open abdominal aortic aneurysm repair, surgical lower limb revascularisation surgery or carotid endarterectomy were recruited. A RIPC or a sham procedure was performed, using a blood pressure cuff, along with preparation for anaesthesia. The RIPC protocol consisting of four cycles of 5 min of ischaemia, followed by 5 min of reperfusion was applied. Arterial stiffness and haemodynamic parameters were measured pre-operatively and 20-28 h after surgery. Two primary outcomes were selected: augmentation index and pulse wave velocity. RESULTS: Ninety-eight patients were randomised. After dropouts 44 and 46 patients were included in the RIPC and sham groups, respectively. Both groups were comparable. There were no statistically significant differences in augmentation index (p = .8), augmentation index corrected for heart rate of 75 beats per minute (p = .8), pulse wave velocity (p = .7), large artery elasticity indices (p = .8), small artery elasticity indices (p = .6), or mean arterial pressure (p = .7) changes between the RIPC and sham groups. There occurred statistically significant (p ≤ .01) improvement in augmentation index (-5.8% vs. -5.5%), augmentation index corrected for a heart rate of 75 beats per minute (-2.5% vs. -2%), small artery elasticity indices (0.7 mL/mmHg × 100 vs. 0.9 mL/mmHg × 100), and mean arterial pressure post-operatively in both the RIPC and the sham groups (change median values in RIPC and sham groups, respectively). CONCLUSIONS: RIPC had no significant effect on arterial stiffness, but there was significant improvement in arterial stiffness after surgery in both groups. Arterial stiffness and haemodynamics may be influenced by surgery or anaesthesia or oxidative stress or all factors combined. Further studies are needed to clarify these findings. CLINICALTRIALS.GOV: NCT02689414.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Kepler T, Kuusik K, Lepner U, et al. The Effect of Remote Ischaemic Preconditioning on Arterial Stiffness in Patients Undergoing Vascular Surgery: A Randomised Clinical Trial. Eur J Vasc Endovasc Surg. 2019. PMID: 31126835. doi:10.1016/j.ejvs.2018.12.002