文献速递主动脉疾病

二维-三维配准融合成像在肾下型EVAR中不劣于三维-三维配准

Two-dimensional-three-dimensional registration for fusion imaging is noninferior to three-dimensional- three-dimensional registration in infrarenal endovascular aneurysm repair.
PubMed 文献 · J Vasc Surg · 2019-05-27

本研究比较二维-三维(2D-3D)与三维-三维(3D-3D)配准融合成像在肾下型腹主动脉瘤腔内修复(EVAR)中的准确性、辐射暴露和易用性。50例连续患者接受2D-3D配准,历史对照为101例3D-3D配准患者。结果显示2D-3D配准在头尾方向偏差上不劣于3D-3D(非劣效界值δ=2.5 mm),且额外辐射和操作时间显著更少。

要点

  • 2D-3D配准融合成像在EVAR中头尾方向偏差不劣于3D-3D配准。
  • 2D-3D配准额外辐射剂量和操作时间显著低于3D-3D配准。
  • 2D-3D配准融合成像可常规用于肾下型EVAR的术中三维导航。

核心结论

  • 2D-3D配准融合成像在EVAR中的准确性不劣于3D-3D配准,且辐射暴露和术中时间需求更少、易用性更优。

研究设计与样本

  • 历史对照为101例接受EVAR并使用3D-3D配准融合成像的患者(3D-3D队列)。

主要发现

  • 2D-3D队列头尾方向偏差为4.6 ± 4.4 mm,3D-3D队列为3.6 ± 3.9 mm,差异无统计学意义(P = .17)。
  • 均值差为1.05 mm(95%CI -2.45至0.34),非劣效检验P = .0249,非劣效界值δ = 2.5 mm。
  • 2D-3D配准额外辐射为0.45 ± 0.28 Gy·cm2,3D-3D队列为45.7 ± 9.1 Gy·cm2(P < .001)。
  • 2D-3D配准操作时间为2.3 ± 1.3分钟,3D-3D队列为5.3 ± 4.3分钟(P < .001)。

关键数值与推荐

  • 非劣效界值δ = 2.5 mm,2D-3D配准头尾方向偏差均值差1.05 mm(95%CI -2.45至0.34),非劣效检验P = .0249。
  • 2D-3D配准额外辐射0.45 ± 0.28 Gy·cm2 vs 3D-3D 45.7 ± 9.1 Gy·cm2(P < .001)。
  • 2D-3D配准操作时间2.3 ± 1.3分钟 vs 3D-3D 5.3 ± 4.3分钟(P < .001)。

临床怎么用

  • 在肾下型EVAR中可采用2D-3D配准融合成像进行术中三维导航,其准确性不劣于3D-3D配准。
  • 2D-3D配准可减少额外辐射暴露和术中操作时间,便于常规开展。

局限性

  • 3D-3D队列为历史对照,非随机同期对照。
  • 2D-3D队列样本量为50例,3D-3D队列为101例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Fusion imaging is a tool for intraoperative three-dimensional (3D) guidance in endovascular aneurysm repair (EVAR). In many aortic centers, the registration for location is based on an intraoperative 3D dataset acquired by means of cone-beam computed tomography (3D-3D registration). Another registration method is based on two two-dimensional (2D) images (lateral and posteroanterior) acquired with the use of intraoperative fluoroscopy for registration with a computed tomographic angiogram (2D-3D registration). The aim of the present study was to compare 2D-3D registration with 3D-3D registration regarding noninferiority in accuracy and to describe radiation exposure and ease of use of both modalities. METHODS: From December 2014 to September 2015, 50 sequentially enrolled patients received EVAR with the use of fusion imaging using 2D-3D registration. No adjustments were made until the first angiography with inserted stent graft. The deviation of fusion imaging to the actual position of the lower renal artery compared with digital subtraction angiography was measured. A historic cohort of 101 patients treated with EVAR and fusion imaging with 3D-3D registration (3D-3D cohort) served as the control group for this study. RESULTS: Craniocaudal deviation did not differ significantly (4.6 ± 4.4 mm in the 2D-3D cohort vs 3.6 ± 3.9 mm in the 3D-3D cohort; P = .17). The difference of the means was 1.05 mm with a 95% confidence interval of -2.45 to 0.34 and a P value for the noninferiority test of .0249, indicating that 2D-3D registration was noninferior in terms of a margin of δ = 2.5 mm. 2D-3D registration was significantly faster with significantly less additional radiation necessary: 0.45 ± 0.28 vs 45.7 ± 9.1 Gy·cm2 in the 3D-3D cohort (P < .001); 2.3 ± 1.3 vs 5.3 ± 4.3 minutes in the 3D-3D cohort (P < .001). CONCLUSIONS: Fusion imaging during EVAR with the use of 2D-3D registration is feasible in routine EVAR. Our findings of two consecutive cohorts with the same clinical, hardware, and software setup used for the procedures underscore that the accuracy of 2D-3D registration is noninferior to that of a 3D-3D registration workflow, with advantages in terms of radiation exposure, intraoperative time demand, and ease of use.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Schulz CJ, Böckler D, Krisam J, et al. Two-dimensional-three-dimensional registration for fusion imaging is noninferior to three-dimensional- three-dimensional registration in infrarenal endovascular aneurysm repair. J Vasc Surg. 2019. PMID: 31147123. doi:10.1016/j.jvs.2019.02.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。