文献速递主动脉疾病

EVAR术后影像监测对再干预与死亡率影响的系统评价与荟萃分析

Effect of Imaging Surveillance After Endovascular Aneurysm Repair on Reinterventions and Mortality: A Systematic Review and Meta-analysis.
PubMed 文献 · J Endovasc Ther · 2019-05-29

该系统评价纳入11项队列研究共21,838例EVAR术后患者,比较依从与部分/不依从影像监测方案者的再干预率和死亡率。结果显示依从者再干预风险差为4%(95%CI 1%至7%),不利于依从组,死亡风险差为12%(95%CI -2%至26%)无统计学意义。提示推荐的年度影像监测可能并非对所有EVAR患者均有益。

要点

  • 依从影像监测的EVAR患者再干预率反而更高,风险差4%(95%CI 1%至7%)。
  • 影像监测依从与否在死亡率上无显著差异,风险差12%(95%CI -2%至26%)。
  • 仅41%至53%的再干预针对影像监测发现的并发症,其余由症状发现。

核心结论

  • 依从影像监测的EVAR患者似乎比部分/不依从者接受更多再干预,但影像监测并未显示降低死亡率。
  • 推荐的年度影像监测可能并非对所有EVAR患者均有益。

研究设计与样本

  • 系统评价与荟萃分析,比较依从与部分/不依从影像监测方案的EVAR患者并发症率。
  • 共纳入11项队列研究,涉及21,838例患者,中位随访31.7个月(四分位距29.8,49.3)。
  • 主要分析指标为再干预和死亡的风险差(RD),汇总RD报告95%CI。
  • 研究方案在PROSPERO注册(CRD42017080494)。

主要发现

  • 总体再干预率为5%,总体死亡率为31%。
  • 再干预率的风险差为4%(95%CI 1%至7%),方向不利于部分/不依从组,需伤害人数为25(95%CI 14至100)。
  • 死亡率的风险差为12%(95%CI -2%至26%),方向不利于部分/不依从组但无统计学意义。
  • 两项研究报告41%至53%的再干预针对影像监测发现的并发症,其余事件通过患者症状发现。

临床怎么用

  • 对EVAR术后患者,不应默认所有患者均从年度影像监测中同等获益,需结合个体风险评估监测策略。
  • 影像监测发现的并发症仅占再干预的一部分,症状驱动的事件发现同样重要。

局限性

  • 纳入研究在影像方式、监测方案及依从性亚组定义上存在差异。
  • 仅11项队列研究,且为观察性设计,可能存在混杂偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Purpose: To study the effects of imaging surveillance after endovascular aortic repair (EVAR) on reintervention and mortality. Materials and Methods: A systematic review was conducted comparing complication rates in EVAR patients compliant with the imaging surveillance protocol vs partially or noncompliant patients. Two authors independently selected articles and performed quality assessment and data extraction. Risk differences for reintervention and mortality between compliant and partially/noncompliant patients were meta-analyzed. The pooled risk difference (RD) is reported with the 95% confidence interval (CI). The review protocol is registered at Prospero (CRD42017080494). Results: A total of 11 cohort studies involving 21,838 patients were included. Studies differed in imaging, their surveillance protocols, and definitions of compliance subgroups. Median follow-up was 31.7 months (interquartile range 29.8, 49.3). The overall reintervention rate was 5%, while the overall mortality was 31%. The RD for the reintervention rate was 4% (95% CI 1% to 7%) in favor of partial/noncompliance [number needed to harm 25 (95% CI 14 to 100)], while mortality showed a nonsignificant RD of 12% (95% CI -2% to 26%) in favor of partial/noncompliance. Two studies reported that 41% to 53% of reinterventions were performed for complications detected through imaging surveillance; the other events were detected through patient symptoms. Conclusion: Patients who are compliant with imaging surveillance appear to undergo more reinterventions than those who are partially or noncompliant. However, imaging surveillance does not seem to protect against mortality. This suggests that the recommended yearly imaging surveillance may not be beneficial for all EVAR patients.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. de Mik SML, Geraedts ACM, Ubbink DT, et al. Effect of Imaging Surveillance After Endovascular Aneurysm Repair on Reinterventions and Mortality: A Systematic Review and Meta-analysis. J Endovasc Ther. 2019. PMID: 31140361. doi:10.1177/1526602819852085

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。