Relay非裸支架在夹层胸主动脉中的形态学表现分析
结果显示TEVAR促进主动脉重塑,假腔完全血栓化比例从术后73%升至随访84%,支架远端新发破口发生率为15%,楔形贴附角是主要危险因素。
要点
- Relay非裸支架TEVAR在急慢性夹层中均促进主动脉重塑,假腔血栓化率随访达84%。
- 支架远端新发破口发生率为15%,楔形贴附角是独立危险因素(OR 1.365)。
- 逆性A型夹层零发生,IA型内漏率4%,迁移距离中位2mm,安全性可接受。
核心结论
- Relay非裸支架TEVAR在急慢性主动脉夹层中促进主动脉重塑,迁移、IA型内漏和逆性A型夹层风险低。
- 楔形贴附是支架远端新发破口的主要危险因素。
研究设计与样本
- 回顾性三维CT分析,纳入两德国中心A型夹层术后残留夹层及急慢性B型夹层患者。
主要发现
- 支架段假腔完全血栓化比例术后73%、随访84%(P < .0001)。
- 支架中段主动脉直径从术前45.9 mm(38.6-56.6)降至随访43.6 mm(37.4-52.4),P = .009。
- 真腔扩张在急性夹层远端锚定区更显著(急性+9.3 mm vs 慢性+5.8 mm,P < .0001)。
- 迁移距离中位2 mm(0-5),鸟嘴和IA型内漏发生率分别为20%和4%,无逆性A型夹层。
- 支架远端新发破口发生率15%,楔形贴附角OR 1.365(CI 1.115-1.671),P = .003。
临床怎么用
- Relay非裸支架可用于急慢性胸主动脉夹层TEVAR,预期可获得良好的主动脉重塑。
- 术前应评估支架楔形贴附角以预判远端新发破口风险,术后随访需关注此并发症。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The aim of this study was to evaluate morphologic changes in dissected aortas after thoracic endovascular aortic repair (TEVAR) with the use of the Relay Nonbare stent graft stent graft by focusing on the geometric stent graft's performance in remodeling aortas. METHODS: We conducted a retrospective three-dimensional computed tomography analysis preoperatively, postoperatively, and 6 months after TEVAR in patients with residual dissection after type A and those with acute and chronic type B dissections at two German centers. RESULTS: Thirty-nine acute and 54 chronic aortic dissections were included. Median follow-up was 200 (interquartile range, 109-617) days. TEVAR induced aortic remodeling in both groups. Complete false lumen thrombosis along the stent graft (postoperative, 73%; follow-up, 84%; P < .0001) led to a decrease in aortic diameter at the middle stent graft level (preoperative, 45.9 mm [38.6-56.6] vs follow-up, 43.6 [37.4-52.4] mm; P = .009). True lumen expansion was observed in both groups and peaked in acute dissections in the distal landing zone (acute, +9.3 mm vs chronic, +5.8 mm; P < .0001). Migration was 2 (0-5) mm, and bird-beak and endoleak type IA rates were 20% and 4%, respectively. There was no retrograde type A dissection. Distal stent graft-induced new entry occurred in 15%; the major risk factor for incidence was the stent graft's wedge apposition angle (odds ratio, 1.365 [confidence interval, 1.115-1.671]; P = .003). CONCLUSIONS: TEVAR with the use of the Relay NBS promotes aortic remodeling in acute and chronic dissections, entailing a low risk of migration, type IA endoleaks, and retrograde type A dissections. Wedge apposition was the predominant risk factor for distal stent graft-induced new entry.
引用
- Lescan M, Czerny M, Berezowski M, et al. Morphologic performance analysis of the Relay nonbare stent graft in dissected thoracic aorta. J Vasc Surg. 2019. PMID: 31126770. doi:10.1016/j.jvs.2019.02.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。