钙化股浅动脉闭塞病变腔内治疗后管腔获得:血管内超声评估的CODE研究
多中心回顾性分析130例症状性股浅动脉原发病变患者,评估钙化模式与腔内治疗后管腔获得的关系。钙化病变的管腔获得显著小于非钙化病变(14.1±4.4 vs 17.8±5.2 mm2,p<0.001),IVUS评估的钙化周向分布与管腔获得独立相关。严重钙化(≥180°)组再狭窄率显著更高,钙化严重程度与支架贴壁不良风险相关。
要点
- 钙化病变的管腔获得显著小于非钙化病变,IVUS评估钙化周向分布是管腔获得的独立预测因素。
- 钙化角度≥180°与术后最小管腔面积相关性最强,且该组再狭窄率显著更高。
- 钙化严重程度与支架贴壁不良风险相关,但与临床驱动的靶病变血运重建无关。
核心结论
- IVUS评估股浅动脉病变钙化可预测腔内治疗后的管腔获得。
- ≥180°弧形严重钙化妨碍单纯球囊扩张或镍钛支架的成功扩张。
- IVUS准确评估钙化模式有助于最大化腔内治疗疗效。
研究设计与样本
- 多中心回顾性研究,纳入7个中心2015年1月至10月间130例症状性股浅动脉原发病变患者(平均年龄73.2±8.4岁,86例男性),均成功接受腔内治疗。
- 主要结局为根据钙化严重程度在术后IVUS图像上测量的最小管腔面积(MLA)所表示的管腔获得。
- 次要结局包括支架贴壁不良率、再狭窄率和临床驱动的靶病变血运重建(TLR)率。
主要发现
- 102例(78.5%)病变存在钙化,平均钙化长度64.3±72.8 mm。
- 透视和造影分类为双侧钙化者70例;IVUS评估50例(49%)病变钙化≥180°。
- 钙化病变管腔获得显著小于28例非钙化病变(14.1±4.4 vs 17.8±5.2 mm2,p<0.001)。
- IVUS评估的钙化周向分布(<180°或≥180°)与腔内治疗后管腔获得独立相关(p<0.001)。
- 钙化角度≥180°与术后MLA相关性最强;严重钙化(≥180°)组再狭窄率显著更高(p<0.018)。
关键数值与推荐
- 钙化病变管腔获得:14.1±4.4 mm2;非钙化病变:17.8±5.2 mm2(p<0.001)。
- IVUS评估钙化周向分布与管腔获得独立相关(p<0.001)。
- 严重钙化(≥180°)组再狭窄率显著更高(p<0.018)。
- 钙化严重程度与支架贴壁不良风险相关(趋势p=0.022),与TLR无关(p=0.57)。
临床怎么用
- 对股浅动脉钙化病变行腔内治疗前,可采用IVUS评估钙化角度和周向分布以预测管腔获得。
- 钙化角度≥180°的严重钙化病变,单纯球囊扩张或镍钛支架可能难以获得满意管腔,需考虑其他预处理策略。
- 严重钙化病变术后再狭窄和支架贴壁不良风险较高,应加强随访监测。
局限性
- 本研究为回顾性设计,可能存在选择偏倚。
- 样本量有限(130例),钙化亚组分析力度受限。
- 仅纳入股浅动脉原发病变,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess calcium patterns in superficial femoral artery (SFA) disease before and after balloon angioplasty ± stent implantation using fluoroscopy, angiography, and intravascular ultrasound (IVUS) imaging and then correlate calcification severity and midterm clinical outcomes. MATERIALS AND METHODS: A multicenter investigation was carried out to retrospectively review 130 symptomatic patients (mean age 73.2±8.4 years; 86 men) with de novo SFA lesions who had successfully undergone endovascular therapy (EVT) at 7 centers between January and October 2015. The primary outcome was lumen gain measured as minimum lumen area (MLA) in post-EVT IVUS images according to calcification severity. The secondary outcomes included rates of stent malapposition, restenosis, and clinically-driven target lesion revascularization (TLR). RESULTS: A total of 102 (78.5%) cases had calcification in the lesions over a mean length of 64.3±72.8 mm. Of these, 70 cases were classified as having bilateral calcification according to fluoroscopy and angiography; 50 (49%) lesions had ≥180° calcification according to IVUS. The lumen gain in calcified lesions was significantly smaller than in the 28 noncalcified lesions (14.1±4.4 vs 17.8±5.2 mm2, p<0.001). IVUS-evaluated circumferential distribution of calcium (<180° or ≥180°) was independently associated with lumen gain after EVT (p<0.001). Among the calcification characteristics, a calcification angle ≥180° showed the strongest correlation to postprocedure MLA. Moreover, the restenosis rate was significantly higher in the severe (≥180°) calcification group (p<0.018). The severity of calcification was also associated with the risk of stent malapposition (p=0.022 for trend) but not TLR (p=0.57). CONCLUSION: IVUS evaluation of calcification in SFA lesions predicted lumen gain after EVT. Severe calcification in a ≥180° arc prevented successful dilation of the lesion with either plain balloon angioplasty or a nitinol stent. Accurate assessment of calcification patterns by IVUS is useful in maximizing the efficacy of endovascular therapy.
引用
- Fujihara M, Kozuki A, Tsubakimoto Y, et al. Lumen Gain After Endovascular Therapy in Calcified Superficial Femoral Artery Occlusive Disease Assessed by Intravascular Ultrasound (CODE Study). J Endovasc Ther. 2019. PMID: 30873909. doi:10.1177/1526602819836095
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。