文献速递主动脉疾病

分支与开窗腔内修复术后桥接支架的几何变化

Geometric changes over time in bridging stents after branched and fenestrated endovascular repair for thoracoabdominal aneurysm.
PubMed 文献 · J Vasc Surg · 2019-03-02

随访中位5.3年,47个分支中12个(26%)闭塞、5个(11%)发生70%-99%狭窄;分支与支架夹角变化≥10度者23个,其中7个闭塞。结论认为分支解剖构型随时间变化,角度改变影响狭窄和闭塞风险,随访应包含CT血管造影测量。

要点

  • 分支/开窗腔内修复术后桥接支架夹角随时间变化,角度改变≥10度与狭窄和闭塞相关。
  • 随访中位5.3年,分支支架1、3、5年免于不良事件率分别为78%、76%、59%。
  • 随访应包含CT血管造影测量主动脉直径、内移植物移位、靶血管支架长度和角度。

核心结论

  • 分支/开窗腔内修复术后分支解剖构型随时间变化,分支与桥接支架角度改变影响狭窄和闭塞可能性。

主要发现

  • 辅助技术成功率为89%,术后30天内5例死亡;剩余23例中位随访5.3年(IQR 2.9-7.2年)。
  • 1年、3年、5年估计总生存率分别为69%、65%、44%。
  • 随访期间47个分支中12个(26%)闭塞,5个(11%)发生70%-99%狭窄。
  • 分支支架1年、3年、5年估计免于不良事件率分别为78%、76%、59%,开窗支架分别为100%、96%、90%。
  • 23个分支夹角变化≥10度,其中7个闭塞、3个发生70%-99%狭窄、4个发生50%-70%狭窄;3例内移植物向尾侧移位>5 mm。

关键数值与推荐

  • 分支支架远端中位移位0.5 mm(IQR -1.9至1.4,P > .05 mm),10个分支移位>10 mm(范围14.1 mm滑入至23.0 mm滑出)。
  • 分支与支架间夹角增加4度(IQR -14至+2度)。

临床怎么用

  • 分支/开窗腔内修复术后随访应包含CT血管造影测量主动脉直径、内移植物移位、靶血管支架长度和角度,以发现断开、狭窄和闭塞。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The objective of this study was to assess long-term durability of bridging stents in branched and combined branched and fenestrated endovascular aneurysm repair (B/F-EVAR) for thoracoabdominal aortic aneurysm (TAAA) and pararenal abdominal aortic aneurysm. METHODS: A retrospective database analysis was performed of patients treated by B/F-EVAR for TAAA. Computed tomography angiography images were analyzed to assess patency, bridging stent angulation and migration, aneurysm diameter, and migration of the endograft. RESULTS: Twenty-eight patients with a median age of 70 years (interquartile range [IQR], 67-77 years) were included. Assisted technical success was 89%. Within 30 days postoperatively, five patients died. In the remaining 23 patients, median follow-up was 5.3 years (IQR, 2.9-7.2 years), and 1-, 3-, and 5-year estimated overall survival was 69%, 65%, and 44%, respectively. During follow-up, 12 of 47 (26%) branches occluded and 5 of 47 (11%) branches developed a 70% to 99% stenosis. The 1-, 3-, and 5-year estimated freedom from adverse events was 78%, 76%, and 59% for branch stents and 100%, 96%, and 90% for fenestration stents, respectively. The median distal bridging stent migration was 0.5 mm (IQR, -1.9 to 1.4; P > .05 mm). In 10 branches, migration >10 mm was seen, ranging from 14.1 mm sliding in to 23.0 mm sliding out. The angulation between branch and stent became 4 degrees more angulated (IQR, -14 to +2 degrees). In 23 branches, the angulation changed 10 degrees or more, leading to an occlusion in 7 branches, a 70% to 99% stenosis in 3 branches, and a 50% to 70% stenosis in 4 branches. In three cases, the endograft migrated >5 mm caudally, with a breach in a fenestration stent in one and a breach in a branch stent in another. CONCLUSIONS: The anatomic configuration of branches in B/F-EVAR of TAAAs and pararenal abdominal aortic aneurysms changes over time. The change in angle of branches and the bridging stent influences the likelihood of stenosis and occlusion. Follow-up of B/F-EVAR should include computed tomography angiography measurements of aortic diameter, endograft migration, target vessel stent length, and angulation to detect disconnection, stenosis, and occlusion.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. de Niet A, Post RB, Reijnen MMPJ, et al. Geometric changes over time in bridging stents after branched and fenestrated endovascular repair for thoracoabdominal aneurysm. J Vasc Surg. 2019. PMID: 30837180. doi:10.1016/j.jvs.2018.12.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。