文献速递主动脉疾病

Endurant支架联合裸球囊扩张支架烟囱EVAR治疗近肾腹主动脉瘤

Chimney Endovascular Aneurysm Repair Using Endurant Stent-Grafts With Bare Balloon-Expandable Stents for Patients With Juxtarenal Aortic Aneurysms.
PubMed 文献 · J Endovasc Ther · 2019-03-22

回顾性分析22例近肾腹主动脉瘤患者使用Endurant支架联合裸球囊扩张支架行烟囱EVAR,技术成功率91%,无术后全身并发症或急性肾损伤,平均随访16.1个月无动脉瘤扩张,最大径缩小至52.9±10.2 mm,烟囱支架通畅率100%。

要点

  • Endurant联合裸球囊扩张支架烟囱EVAR短期技术成功率达91%。
  • 随访期烟囱支架通畅率100%,无新发Ia型内漏或动脉瘤相关事件。
  • 适用于无覆膜支架可用时的高危近肾腹主动脉瘤患者。

核心结论

  • 使用Endurant支架联合裸球囊扩张支架行烟囱EVAR在无覆膜支架可用时短期结果良好,可用于高危近肾腹主动脉瘤患者。

主要发现

  • 技术成功率为91%(20/22),2例(9%)出现轻微Ia型内漏。
  • 术后无全身并发症或急性肾损伤(Acute Kidney Injury Network分期2级及以上)。
  • 平均影像学观察期16.1±9.6个月,期间无动脉瘤扩张(>5 mm)。
  • 平均最大动脉瘤直径缩小至52.9±10.2 mm(与术前比较p<0.001),个体平均瘤囊回缩6.2±5.9 mm。
  • 烟囱支架总体一期通畅率100%;2例术中Ia型内漏中1例在6个月影像时 resolved,随访中无新发Ia型内漏,无额外治疗或动脉瘤相关事件。

关键数值与推荐

  • 最大动脉瘤直径59.1±11.9 mm,近端瘤颈长度5.2±2.9 mm。
  • 22例中9例(40%)存在近端瘤颈成角,9例(40%)为锥形瘤颈。
  • 19例使用单烟囱,3例使用双烟囱,均为裸球囊扩张支架;2例在裸支架内追加自膨式覆膜支架。

临床怎么用

  • 在覆膜支架不可用时,可考虑Endurant联合裸球囊扩张支架行烟囱EVAR治疗高危近肾腹主动脉瘤患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the advantages of chimney endovascular aneurysm repair (chEVAR) using an Endurant stent-graft with uncovered balloon-expandable stents (BES) for patients with juxtarenal aortic aneurysms. MATERIALS AND METHODS: Twenty-two patients (mean age 78.5±9.0 years; 13 men) who underwent chEVAR using Endurant and uncovered BES between January 2014 and December 2017 were analyzed retrospectively. The maximum aneurysm diameter was 59.1±11.9 mm, and the proximal neck length was 5.2±2.9 mm. Of the 22 cases, 9 (40%) involved proximal neck angulation and 9 (40%) had a conical neck. Single and double chimneys were performed using BES in 19 and 3 cases, respectively. In 2 cases, an additional self-expanding covered stent was used inside the uncovered BES. RESULTS: The technical success was 91% (20/22) as 2 (9%) cases showed minor type Ia endoleak. No postoperative systemic complications or acute renal dysfunction (Acute Kidney Injury Network classification stage 2 or higher) were observed. The mean radiologic observation period was 16.1±9.6 months, and no aneurysm expansion (>5 mm) was observed during this time. The mean maximum aneurysm diameter decreased to 52.9±10.2 mm (p<0.001 vs preoperative), with an individual mean sac regression of 6.2±5.9 mm. Overall primary chimney stent patency was 100%. One of the 2 cases of intraoperative type Ia endoleak resolved at the 6-month imaging, and no new type Ia endoleaks developed in any cases at follow-up. No additional treatment- or aneurysm-related events were observed. CONCLUSION: Short-term outcomes of chEVAR using Endurant with uncovered BES have been favorable when covered stents were unavailable, and it can be useful for high-risk patients with juxtarenal aortic aneurysms.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Morikage N, Mizoguchi T, Takeuchi Y, et al. Chimney Endovascular Aneurysm Repair Using Endurant Stent-Grafts With Bare Balloon-Expandable Stents for Patients With Juxtarenal Aortic Aneurysms. J Endovasc Ther. 2019. PMID: 30900510. doi:10.1177/1526602819837311

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。