包被光纤与径向光纤在体外大隐静脉属支EVLA中的组织病理学差异
本研究利用体外模型,比较1470nm静脉腔内激光(EVL)使用包被光纤与径向光纤对离体大隐静脉优势筋膜外属支的生物学效应。结果显示,径向光纤所致损伤更均匀且无组织碳化,两种光纤在60和80 J/cm能量密度下均导致透壁性细胞死亡。
要点
- 径向光纤损伤模式更均匀,无组织碳化。
- 两种光纤在60和80 J/cm下均致透壁性坏死或凋亡。
- 包被光纤在相同能量密度下出现组织碳化。
核心结论
- 包被光纤与径向光纤在体外EVL消融中的效应存在显著差异,径向光纤损伤更均匀且无碳化。
研究设计与样本
- 离体实验研究,采用10段大隐静脉优势筋膜外属支,6段用包被光纤、4段用径向光纤,于10W下按0、20、40、60、80 J/cm五个线性静脉内能量密度(LEED)处理,处理后6和24小时收集标本行组织学和免疫组化分析。
主要发现
- 径向光纤所致损伤模式比包被光纤更均匀,且无组织碳化。
- 在LEED 60和80 J/cm时,两组均观察到显著透壁性损伤和坏死。
- 在相同LEED下,p53和caspase 3分析显示两种光纤处理后6小时均出现透壁性静脉壁细胞死亡(坏死或凋亡)。
- 包被光纤在相同LEEDs下出现组织碳化。
临床怎么用
- 体外模型提示径向光纤可能减少组织碳化并实现更均匀的静脉壁损伤,但临床转化需进一步验证。
局限性
- 研究为离体体外模型,样本量小(共10段静脉),结果不能直接外推至临床。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The study aimed to investigate the biologic effects of the 1470-nm endovenous laser (EVL), with a jacketed fiber and a radial fiber, during EVL ablation of an ex vivo dominant extrafascial tributary of the great saphenous vein in our in vitro model by histology and immunohistochemistry. METHODS: Ten segments of the dominant extrafascial tributary of the great saphenous vein were harvested by a consultant vascular surgeon from patients during routine varicose vein surgery. Six segments were treated using an ex vivo model of our design by a 1470-nm EVL with a jacketed fiber. The other four segments were also treated by a 1470-nm EVL but with a radial-firing fiber. Each segment was split into five sections and treated at five different linear endovenous energy densities (LEEDs) at 10 W: 0, 20, 40, 60, and 80 J/cm. The veins were incubated and subsections collected at 6 and 24 hours after treatment. Subsections were immersed in buffered formalin and taken for histologic and immunohistochemical analysis. Histopathologic analysis was then performed. RESULTS: Treatment with the radial fiber led to a pattern of damage that was more homogeneous than with the jacketed fiber, with no carbonization of tissue present. Significant transmural damage and necrosis were observed at LEEDs of 60 and 80 J/cm in both treatment groups. At the same LEEDs, p53 and caspase 3 analysis showed that transmural cell wall vein death (necrosis or apoptosis) occurred by 6 hours after treatment with both fibers. CONCLUSIONS: There was a significant difference in the effects of treatment with a jacketed fiber and a radial fiber in EVL ablation in vitro. Although both fibers caused transmural vein wall cell death at similar LEEDs, the pattern of damage with the radial fiber was more homogeneous. There was no overtreatment of tissue in terms of carbonization after treatment with the radial fiber. Treatment with the jacketed fiber showed carbonization of tissue at the same LEEDs.
引用
- Ashpitel HF, Dabbs EB, Salguero FJ, et al. Histopathologic differences in the endovenous laser ablation between jacketed and radial fibers, in an ex vivo dominant extrafascial tributary of the great saphenous vein in an in vitro model, using histology and immunohistochemistry. J Vasc Surg Venous Lymphat Disord. 2019. PMID: 30771831. doi:10.1016/j.jvsv.2018.09.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。