文献速递颈动脉与弓上血管

钙化斑块所致声影下收缩期峰值流速无法准确评估颈动脉狭窄程度

Peak Systolic Velocity for Calcified Plaques Fails to Estimate Carotid Stenosis Degree.
PubMed 文献 · Ann Vasc Surg · 2019-02-22

本研究在36个月内对1178例颈动脉行双功超声检查,其中62条存在钙化斑块所致声影的颈动脉同时接受PSV和CTA评估。结果显示PSV与CTA一致率仅50%,PSV低估严重狭窄27.79%,高估中度和轻度狭窄61.91%和37.78%。结论认为钙化斑块声影下PSV单独不足以量化颈动脉狭窄,推荐CTA辅助决策。

要点

  • 钙化斑块声影下PSV与CTA一致率仅50%,低估严重狭窄27.79%。
  • PSV>125 cm/s预测>50%狭窄敏感性63.3%,>230 cm/s预测>70%狭窄敏感性27.8%。
  • 存在声影时建议用CTA等影像工具辅助临床决策。

核心结论

  • 钙化斑块所致声影存在时,PSV单独不足以量化颈动脉狭窄程度。
  • 推荐使用CTA等其他影像工具辅助临床决策。

研究设计与样本

  • 回顾性分析36个月内1178例颈动脉DUS检查,164条颈动脉存在钙化斑块所致声影。
  • 62条颈动脉同时接受DUS/PSV和CTA评估,CTA以面积减少计算狭窄百分比。

主要发现

  • PSV分类为严重10条、中度21条、轻度31条;CTA分类为严重36条、中度8条、轻度18条。
  • PSV低估严重狭窄27.79%,高估中度狭窄61.91%、轻度狭窄37.78%。
  • 两种影像一致率50%,DUS/PSV与CTA相关性r=0.668(P<0.0001,95%CI 0.502-0.786)。

关键数值与推荐

  • DUS/PSV分级标准:轻度PSV<125 cm/s,中度125≤PSV≤230 cm/s,重度PSV>230 cm/s。
  • PSV>125 cm/s预测>50%狭窄:敏感性63.3%,特异性100%,阳性预测值100%,阴性预测值71.9%。
  • PSV>230 cm/s预测>70%狭窄:敏感性27.8%,特异性100%,阳性预测值100%,阴性预测值50%。

临床怎么用

  • 颈动脉DUS发现钙化斑块伴声影时,不应仅凭PSV判断狭窄程度。
  • 对此类病变建议加做CTA以准确评估狭窄,指导临床决策。

局限性

  • 仅62条颈动脉同时接受DUS/PSV和CTA分析,样本量有限。
  • 单中心研究,PSV测量在声影结束后立即进行,可能影响可重复性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Duplex ultrasonography (DUS), although consolidated as the primary tool for the estimation of carotid stenosis, may be impaired by calcified plaques that promote acoustic shadow (AcS). AcS seems to hamper the quantification of the main parameter used in the determination of percentage stenosis, that is, the maximal peak systolic velocity (PSV) at the lesion site. The aim of our study was to compare the degrees of carotid artery stenosis in DUS/PSV and computed tomography angiography (CTA) in the presence of AcS. METHODS: During 36 months, 1,178 carotid DUS tests were performed. A total of 164 carotids in 139 patients showed AcS resulting from calcified plaques. Carotids with AcS were referred for a second imaging examination; thus, 62 carotids were analyzed by both DUS/PSV and CTA. CTA measured the area reduction at the lesion site to calculate the percent stenosis. PSV was measured immediately after the end of the AcS. According to velocities-based DUS criteria, stenoses were classified as mild (PSV < 125 cm/s), moderate (125 ≤ PSV ≤ 230 cm/s), and severe (PSV > 230). CTA and DUS/PSV measurements were compared to determine the accuracy of PSV in characterizing the severity of carotid stenosis with AcS. RESULTS: Of the 62 lesions, PSV characterized 10 as severe, 21 as moderate, and 31 as mild. According to the CTA study, there were 36 severe, 8 moderate, and 18 mild lesions. PSV underestimated in 27.79% the incidence of cases of severe carotid artery stenosis detected by the CTA. In addition, PSV overestimated the incidence of the cases of moderate and mild stenosis in 61.91% and 37.78%, respectively. The agreement ratio between the imaging examinations used in this study was 50%. DUS/PSV discretely correlated with CTA (r = 0.668, P < 0.0001, 95% confidence interval = 0.502-0.786). Using PSVs >125 and >230 as predictors of carotid lesions higher than 50% and 70%, respectively, the sensitivities were 63.3% and 27.8%, the specificities were 100%, the positive predictive values were 100%, and the negative predictive values were 71.9% and 50%. CONCLUSION: PSV alone is inadequate to quantify carotid stenosis in the presence of calcified plaques and AcS. Another image tool, such as CTA, could be recommendable for clinical decision-making.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Morales MM, Anacleto A, Filho CM, et al. Peak Systolic Velocity for Calcified Plaques Fails to Estimate Carotid Stenosis Degree. Ann Vasc Surg. 2019. PMID: 30802575. doi:10.1016/j.avsg.2018.12.086

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。