颈动脉内膜切除术对颈动脉狭窄患者视觉功能的影响
本研究连续纳入15例严重颈动脉狭窄(>70%)行CEA的患者,评估术前术后主观与客观视觉功能及视网膜结构。结果显示CEA后视力、视野、眼压及视觉诱发电位P2潜伏期等指标改善,但视网膜神经纤维层厚度无显著变化。
要点
- CEA可改善严重颈动脉狭窄患者的主观视力与视野指标
- CEA后眼压显著下降,闪光VEP P2潜伏期缩短
- 视网膜神经纤维层厚度在CEA后无显著改变
核心结论
- CEA后颈动脉与眼动脉血流改善可增强颈动脉狭窄患者的主观和客观视觉功能评估,包括视力、动态与静态视野、P2潜伏期及眼压振幅,但未影响视网膜神经纤维层厚度。
研究设计与样本
- 观察性研究,连续纳入2015年9月至2016年7月拟行CEA的严重颈动脉狭窄(标准颈动脉双功超声或动脉造影示>70%)患者15例(11男4女,共30眼,平均年龄62.8±5.0岁)。
主要发现
- CEA后未矫正视力与最佳矫正视力均改善。
- 眼压从17.41±2.59降至15.95±2.50 mm Hg(P=0.0022)。
- 动态视野范围显著增加(P=0.0126),平均敏感度从18.8±5.5升至20.6±4.3 dB(P=0.0208),平均缺损从8.2±5.3降至6.5±4.2 dB(P=0.025)。
- 闪光VEP的P2波潜伏期在CEA后显著缩短(P=0.0151),ERG波形3的振荡电位振幅显著增加。
- 视网膜神经纤维层厚度无显著改变。
临床怎么用
- 对严重颈动脉狭窄患者行CEA前应完善标准化眼科评估,包括视力、眼压、视野及VEP/ERG检查。
- CEA后可通过复查视力、眼压、视野及VEP/ERG客观评估视觉功能改善情况。
局限性
- 样本量小(15例患者、30眼),为观察性研究,未设对照组。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Carotid endarterectomy (CEA) is deemed to restore the blood flow of the carotid and ophthalmic arteries in patients with carotid artery stenosis. However, specific changes in visual function before and after CEA are not well understood; hence, this observational study aimed to investigate the functional and structural changes in vision after CEA in those patients. METHODS: Patients with severe carotid artery stenosis (>70% with standard carotid duplex scanning or arteriography) scheduled to undergo CEA were consecutively recruited for the study between September 2015 and July 2016. All patients underwent a standardized ophthalmic examination, including intraocular pressure (IOP) measurement, slit-lamp examination, and fundus examination. Visual acuity, best corrected visual acuity (BCVA), and kinetic and static visual fields (VFs) were tested to evaluate subjective visual function. Flash and pattern visual evoked potentials (VEPs) and an electroretinogram (ERG) were measured for objective visual function. Retinal nerve fiber layer (RNFL) thickness was scanned using optical coherence tomography for structural evaluation. RESULTS: The study involved 15 patients (11 male and 4 female, corresponding to 30 eyes; mean age 62.8 ± 5.0 years). After CEA, both uncorrected visual acuity and BCVA improved, and IOP significantly decreased from 17.41 ± 2.59 to 15.95 ± 2.50 mm Hg (P = 0.0022). Kinetic VF range increased significantly (P = 0.0126) as did mean sensitivity from 18.8 ± 5.5 to 20.6 ± 4.3 dB (P = 0.0208), whereas mean defect decreased from 8.2 ± 5.3 to 6.5 ± 4.2 dB (P = 0.025). RNFL thickness was not significantly altered. Latency of the P2 wave on flash VEP reduced significantly after CEA (P = 0.0151), whereas the oscillatory potential amplitude of waveform 3 in the ERG significantly increased after CEA. CONCLUSIONS: Our results demonstrate that an improvement in carotid artery and ophthalmic artery blood flow after CEA does indeed enhance subjective and objective assessments of visual function in patients with carotid artery stenosis, including visual acuity, kinetic and static VF, P2 latency, and ocular pressure amplitude; however, it did not affect RNFL thickness.
引用
- Yan J, Yang X, Wu J, et al. Visual Outcome of Carotid Endarterectomy in Patients with Carotid Artery Stenosis. Ann Vasc Surg. 2019. PMID: 30769057. doi:10.1016/j.avsg.2018.12.069
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。