定制一体式锥形覆膜支架用于窄分叉囊状肾下腹主动脉瘤择期EVAR

Custom-Made Unibody Conical Endografts for Elective Endovascular Repair of Saccular Infrarenal Abdominal Aortic Aneurysms with Narrow Aortic Bifurcations-Novel Implementation of the Aortoaortic Concept.
PubMed 文献 · Ann Vasc Surg · 2019-02-23

本文报告3例窄主动脉分叉(AB宽度≤20 mm)的囊状肾下腹主动脉瘤患者,因分叉型支架不适用,采用定制一体式锥形覆膜支架(主髂动脉概念)行择期EVAR;技术成功率100%,术后1个月CTA示近远端完全密封、支架贴合良好,随访期内无内漏及支架相关并发症。

要点

  • 窄主动脉分叉(≤20 mm)的囊状肾下AAA可考虑定制一体式锥形覆膜支架行EVAR。
  • 3例技术成功率100%,术后1个月CTA示近远端完全密封、贴合良好。
  • 最长随访内无任何类型内漏、无支架骨折/血栓/移位及再干预。

核心结论

  • 在合适解剖条件下,定制一体式锥形覆膜支架用于窄分叉囊状肾下AAA择期EVAR技术可行,短期在内漏与移位方面安全性良好。

研究设计与样本

  • 单中心经验描述,纳入3例窄主动脉分叉(≤20 mm)的囊状肾下腹主动脉瘤患者,行定制一体式锥形覆膜支架择期EVAR。

主要发现

  • 技术成功率为100%。
  • 术后1个月CTA显示3例均实现近端与远端完全密封,支架贴合性良好。
  • 最长随访内所有患者无任何类型内漏,无支架骨折、血栓或移位等支架相关并发症,无需再干预。

关键数值与推荐

  • 主动脉分叉宽度≤20 mm被视为分叉型支架不理想的解剖条件。
  • 技术成功率100%,术后1个月CTA近远端完全密封,随访期无内漏及支架相关并发症。

临床怎么用

  • 对分叉过窄、不适合分叉型支架的囊状肾下AAA,可评估定制一体式锥形覆膜支架作为个体化EVAR方案。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The aortoaortic concept for endovascular repair (EVAR) of infrarenal abdominal aortic aneurysms (AAAs) is nearly forgotten but may constitute a valuable option for focal pathologies. Herein, we describe our experience using custom-made (CM) unibody conical endografts for saccular AAAs with narrow (≤20 mm wide) aortic bifurcation (AB) in three patients. Given the narrow AB, the option for a bifurcated stent graft was reputed not optimal. Therefore, we decided to further suggest the construction of a CM unibody conical stent graft with respect to unique anatomical characteristics of the patients. Technical success rate was 100%, and computed tomography angiography at first-month follow-up showed complete sealing proximally and distally with excellent conformability of the endografts in all the cases. All the patients were free from any-type endoleak (EL) and had no evidence of any endograft-related complication (i.e., fracture, thrombosis, or migration) or required any reintervention at their longest follow-up. We conclude that in the proper anatomic setting, the use of CM unibody conical endografts for elective EVAR of saccular AAAs with narrow AB is technically feasible with excellent short-term safety regarding ELs or migration.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. D'Oria M, Pipitone M, Riccitelli F, et al. Custom-Made Unibody Conical Endografts for Elective Endovascular Repair of Saccular Infrarenal Abdominal Aortic Aneurysms with Narrow Aortic Bifurcations-Novel Implementation of the Aortoaortic Concept. Ann Vasc Surg. 2019. PMID: 30802571. doi:10.1016/j.avsg.2018.12.102