文献速递主动脉疾病

Excluder支架织物撕裂致迟发型IIIb内漏的外科治疗

Surgery for a Late Type IIIb Endoleak From a Fabric Tear of an Excluder Stent Graft.
PubMed 文献 · Ann Vasc Surg · 2019-02-22

一例85岁男性EVAR术后10年出现腹主动脉瘤扩张,既往因持续II型内漏行腰动脉弹簧圈栓塞,瘤囊从49mm×55mm扩大至78mm×90mm,急诊开腹确诊为主体织物撕裂所致IIIb型内漏,用纤维蛋白封闭贴片控制出血,次日于支架内放置28mm×3cm Excluder主动脉延长段加固,1年随访稳定无再扩张。

要点

  • EVAR术后迟发瘤囊扩张需警惕IIIb型内漏,尤其Excluder支架主体织物撕裂。
  • 近端锚定区不足时,急诊开腹联合纤维蛋白封闭贴片可控制IIIb型内漏出血。
  • 支架内放置主动脉延长段可加固止血部位,1年随访瘤囊无再扩张。

核心结论

  • Excluder支架主体织物撕裂可致迟发型IIIb内漏,急诊开腹联合支架内延长段加固可有效控制出血并稳定瘤囊。

研究设计与样本

  • 单例病例报告:85岁男性,EVAR术后10年,因间歇性腹痛转诊。

主要发现

  • 瘤囊最大径从初始49mm×55mm扩大至78mm×90mm,支架近端周围见造影剂。
  • 急诊开腹确诊为主体织物撕裂所致IIIb型内漏,用纤维蛋白封闭贴片控制出血。
  • 次日于主体内放置28mm×3cm Excluder主动脉延长段加固止血部位。
  • 1年随访病情稳定,瘤囊无再扩张证据。

关键数值与推荐

  • 瘤囊从49mm×55mm扩大至78mm×90mm。
  • 既往因持续II型内漏行腰动脉弹簧圈栓塞,EVAR后4、6、8年瘤囊持续扩张。
  • 使用28mm×3cm Excluder主动脉延长段置于主体内。
  • 1年随访无瘤囊再扩张。

临床怎么用

  • EVAR术后迟发瘤囊扩张需鉴别IIIb型内漏,近端锚定区不足时可考虑急诊开腹。
  • 术中发现织物撕裂可用纤维蛋白封闭贴片止血,支架内放置延长段加固。

局限性

  • 单例病例报告,结论外推受限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

An 85-year-old male patient, who had undergone endovascular abdominal aortic aneurysm repair (EVAR) using the Gore Excluder stent graft 10 years ago, was referred for intermittent abdominal pain. He also received coil embolization of the lumbar arteries for a persistent type II endoleak, resulting in continued aneurysmal dilation at 4, 6, and 8 years after the EVAR. The maximum size of the aneurysm sac was dilated from the initial size of 49 mm × 55 mm to 78 mm × 90 mm, and the contrast medium was observed around the proximal portion of the stent graft, suggesting the presence of a type Ia or II endoleak. Because the definite cause of the dilation was unclear and adequate proximal landing zone was not available to deploy an aortic cuff, emergent laparotomy was indicated to treat this symptomatic aneurysm dilation. A type IIIb endoleak due to fabric disruption of the main body was diagnosed, and the bleeding was controlled using a fibrin sealant patch. To reinforce the hemostasis site from the inside of the stent graft, a 28 mm × 3-cm Excluder aortic cuff was deployed inside the main trunk next day. At 1-year follow-up, his condition was stable without evidence of reexpansion of the aneurysmal sac.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Matsuo J, Omura A, Matsuda H, et al. Surgery for a Late Type IIIb Endoleak From a Fabric Tear of an Excluder Stent Graft. Ann Vasc Surg. 2019. PMID: 30802563. doi:10.1016/j.avsg.2018.12.101

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。