文献速递主动脉疾病

Endurant支架联合Heli-FX EndoAnchors扩大破裂腹主动脉瘤全腔内修复适用性

Expanded Suitability of Ruptured Abdominal Aortic Aneurysms for Total Endovascular Repair Using the Endurant Endograft and Heli-FX EndoAnchors.
PubMed 文献 · J Endovasc Ther · 2019-02-01

本研究基于90例破裂腹主动脉瘤患者的CT分析,评估Endurant支架联合Heli-FX EndoAnchors扩大EVAR适用性的潜力。结果显示仅38.9%患者符合Endurant说明书(IFU)标准,颈长<10mm是主要限制因素;联合EndoAnchors并纠正髂动脉问题后,适用比例可从38.9%提升至56.7%,若同时克服髂动脉问题可达75.6%。

要点

  • 颈长<10mm是破裂腹主动脉瘤不适合标准EVAR的主要原因。
  • 仅38.9%患者完全符合Endurant支架IFU标准。
  • 联合EndoAnchors并纠正髂动脉问题可将适用性提升至56.7%–75.6%。

核心结论

  • 联合EndoAnchors并纠正髂动脉不良解剖,可使破裂腹主动脉瘤EVAR适用性接近翻倍。

研究设计与样本

  • 回顾性分析2个三级中心2014年1月至2018年1月收治的90例破裂腹主动脉瘤患者的CT扫描。
  • 患者平均年龄73.2±9岁,其中87例为男性。

主要发现

  • 颈长<10mm者41例(45.6%),颈直径超出IFU者5例,锥形颈者45例(50.0%)。
  • 无血栓者63例(70.0%),无钙化者73例(81.1%)。
  • 符合全部颈部标准者44例(48.9%),但总体IFU符合者仅35例(38.9%),其中21例因髂动脉问题不符合。

关键数值与推荐

  • 全部研究组加用EndoAnchors可额外覆盖24例患者,其中8例需联合髂动脉手术。
  • 若克服部分髂动脉问题,EVAR适用比例从48.9%升至75.6%;不纠正髂动脉缺陷则从38.9%升至56.7%。

临床怎么用

  • 对颈长<10mm的破裂腹主动脉瘤患者,可考虑Endurant支架联合EndoAnchors以扩大腔内修复适应证。
  • 评估适用性时需同时关注髂动脉解剖,必要时联合髂动脉手术以进一步提高EVAR覆盖率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess if the suitability of endovascular aneurysm repair (EVAR) of ruptured abdominal aortic aneurysms (RAAAs) can be expanded by combining the Endurant stent-graft with the Heli-FX EndoAnchors. MATERIALS AND METHODS: Contrast-enhanced computed tomography (CT) scans of 90 patients (mean age 73.2±9 years; 87 men) with RAAA admitted between January 2014 and January 2018 in 2 tertiary care centers were analyzed in a 3-dimensional workstation. Anatomical features of the aneurysms according to the instructions for use (IFU) for the Endurant endograft were evaluated and expansion of treatment with Heli-FX EndoAnchors was assessed. RESULTS: Neck length <10 mm was present in 41 (45.6%) patients; 5 had neck diameters outside the IFU and 45 (50.0%) had conical necks. Thrombus and calcium were absent in 63 (70.0%) and 73 (81.1%), respectively. In the study cohort, 44 (48.9%) patients met all the neck criteria, although overall IFU compliance was found in only 35 (38.9%) patients due to iliac-related issues in 21 patients. The adjunctive use of EndoAnchors in the entire study group would enhance the therapeutic range to an additional 24 patients, 8 of whom would need an associated iliac procedure. This represents an expansion of the total EVAR approach from 48.9% to 75.6% of cases if some iliac issues are overcome and from 38.9% to 56.7% without correcting iliac deficiencies. CONCLUSION: The main reason of being unfit for endovascular treatment in this series was neck length <10 mm. Based on this analysis, nearly 40% of RAAA patients would have been candidates for EVAR based on the IFU neck criteria for the Endurant stent-graft. This suitability could be nearly doubled with the use of EndoAnchors and correction of unsuitable iliac anatomy. The use of EndoAnchors has the potential to offer a significant benefit in the endovascular treatment of RAAA patients.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Reyes Valdivia A, Álvarez Marcos F, Duque Santos Á, et al. Expanded Suitability of Ruptured Abdominal Aortic Aneurysms for Total Endovascular Repair Using the Endurant Endograft and Heli-FX EndoAnchors. J Endovasc Ther. 2019. PMID: 30706754. doi:10.1177/1526602819828377

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。