Endurant支架联合Heli-FX EndoAnchors扩大破裂腹主动脉瘤全腔内修复适用性
本研究基于90例破裂腹主动脉瘤患者的CT分析,评估Endurant支架联合Heli-FX EndoAnchors扩大EVAR适用性的潜力。结果显示仅38.9%患者符合Endurant说明书(IFU)标准,颈长<10mm是主要限制因素;联合EndoAnchors并纠正髂动脉问题后,适用比例可从38.9%提升至56.7%,若同时克服髂动脉问题可达75.6%。
要点
- 颈长<10mm是破裂腹主动脉瘤不适合标准EVAR的主要原因。
- 仅38.9%患者完全符合Endurant支架IFU标准。
- 联合EndoAnchors并纠正髂动脉问题可将适用性提升至56.7%–75.6%。
核心结论
- 联合EndoAnchors并纠正髂动脉不良解剖,可使破裂腹主动脉瘤EVAR适用性接近翻倍。
研究设计与样本
- 回顾性分析2个三级中心2014年1月至2018年1月收治的90例破裂腹主动脉瘤患者的CT扫描。
- 患者平均年龄73.2±9岁,其中87例为男性。
主要发现
- 颈长<10mm者41例(45.6%),颈直径超出IFU者5例,锥形颈者45例(50.0%)。
- 无血栓者63例(70.0%),无钙化者73例(81.1%)。
- 符合全部颈部标准者44例(48.9%),但总体IFU符合者仅35例(38.9%),其中21例因髂动脉问题不符合。
关键数值与推荐
- 全部研究组加用EndoAnchors可额外覆盖24例患者,其中8例需联合髂动脉手术。
- 若克服部分髂动脉问题,EVAR适用比例从48.9%升至75.6%;不纠正髂动脉缺陷则从38.9%升至56.7%。
临床怎么用
- 对颈长<10mm的破裂腹主动脉瘤患者,可考虑Endurant支架联合EndoAnchors以扩大腔内修复适应证。
- 评估适用性时需同时关注髂动脉解剖,必要时联合髂动脉手术以进一步提高EVAR覆盖率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess if the suitability of endovascular aneurysm repair (EVAR) of ruptured abdominal aortic aneurysms (RAAAs) can be expanded by combining the Endurant stent-graft with the Heli-FX EndoAnchors. MATERIALS AND METHODS: Contrast-enhanced computed tomography (CT) scans of 90 patients (mean age 73.2±9 years; 87 men) with RAAA admitted between January 2014 and January 2018 in 2 tertiary care centers were analyzed in a 3-dimensional workstation. Anatomical features of the aneurysms according to the instructions for use (IFU) for the Endurant endograft were evaluated and expansion of treatment with Heli-FX EndoAnchors was assessed. RESULTS: Neck length <10 mm was present in 41 (45.6%) patients; 5 had neck diameters outside the IFU and 45 (50.0%) had conical necks. Thrombus and calcium were absent in 63 (70.0%) and 73 (81.1%), respectively. In the study cohort, 44 (48.9%) patients met all the neck criteria, although overall IFU compliance was found in only 35 (38.9%) patients due to iliac-related issues in 21 patients. The adjunctive use of EndoAnchors in the entire study group would enhance the therapeutic range to an additional 24 patients, 8 of whom would need an associated iliac procedure. This represents an expansion of the total EVAR approach from 48.9% to 75.6% of cases if some iliac issues are overcome and from 38.9% to 56.7% without correcting iliac deficiencies. CONCLUSION: The main reason of being unfit for endovascular treatment in this series was neck length <10 mm. Based on this analysis, nearly 40% of RAAA patients would have been candidates for EVAR based on the IFU neck criteria for the Endurant stent-graft. This suitability could be nearly doubled with the use of EndoAnchors and correction of unsuitable iliac anatomy. The use of EndoAnchors has the potential to offer a significant benefit in the endovascular treatment of RAAA patients.
引用
- Reyes Valdivia A, Álvarez Marcos F, Duque Santos Á, et al. Expanded Suitability of Ruptured Abdominal Aortic Aneurysms for Total Endovascular Repair Using the Endurant Endograft and Heli-FX EndoAnchors. J Endovasc Ther. 2019. PMID: 30706754. doi:10.1177/1526602819828377
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。